AGKABEL Fire Resistant Single Core Cables – FR-H, FR-XH, FR-XAH (Mica Tape, LSZH, 600/1000V)

AGKABEL Fire Resistant Single Core Cables (FR-H, FR-XH, FR-XAH) are high-performance safety cables designed to maintain circuit integrity during extreme fire conditions. Featuring a critical Mica Tape fire barrier wrapped around plain annealed copper conductors, these cables ensure critical power systems continue to function. Available in non-sheathed (FR-H), unarmoured LSZH (FR-XH), and Aluminium Wire Armoured LSZH (FR-XAH) options, they are rated for 600/1000V and offer XLPE (90°C) or XLEVA (110°C) insulation. Fully compliant with IEC 60331 and BS 6387, they are the ideal choice for emergency lighting, fire alarms, and safety-critical infrastructure.

AGKABEL GRUPPE LIMITED presents a comprehensive range of Fire Resistant Single Core Cables, engineered to maintain circuit integrity and ensure safety during extreme fire conditions. Available in three distinct configurations—FR-H (Insulated, Non-Sheathed), FR-XH (Unarmoured), and FR-XAH (Armoured)—these cables are built with a critical Mica Tape fire barrier wrapped around the conductor. This barrier ensures that the cable continues to function (providing power to critical systems like fire alarms, emergency lighting, and smoke extraction fans) even when exposed to direct flame.

The cables feature a Plain Annealed Copper conductor, insulation options of XLPE (max 90°C) or XLEVA (max 110°C), and Low Smoke Zero Halogen (LSZH) bedding and sheathing. The FR-XAH variant includes an Aluminium Wire Armour for additional mechanical protection. Compliant with rigorous international standards including IEC 60331 and BS 6387, these cables provide exceptional fire resistance and low toxicity in emergency scenarios.

Technical Data

  • Conductor: Plain Annealed Copper (Class 2 stranding)

  • Fire Barrier: Mica Tape

  • Insulation: (a) XLPE Compound or (b) XLEVA Compound

  • Bedding: LSZH Compound

  • Armouring: Aluminium Wire (FR-XAH only)

  • Sheath: LSZH Compound (Colour: Insulation – Natural)

  • Reference Standard: IEC 60502 / BS 721

  • Test Standards:

    • Fire Resistance: IEC 60331 (Cat A, B, C), BS 6387 (C, W, Z), SS299 (C)

    • Flame Retardance: IEC 60332-3, BS 4066

    • Halogen & Smoke: IEC 60754, BS 6425, IEC 61034, BS 7622-Part 2

  • Voltage Uo/U: 600/1000V

  • Operating Temperature: (a) Max 90°C for XLPE, (b) Max 110°C for XLEVA

  • Minimum Bending Radius: 8D for unarmoured cable, 10D for armoured cable.

Technical Specifications Table (Extract)

Nominal Conductor Area (mm²) No. & Dia. of Wires (no./mm) FR-H Radial Thick. of Insulation (mm) FR-H Overall Dia. (mm) FR-XH Radial Thick. of Insulation (mm) FR-XH Overall Dia. (mm) FR-XAH Overall Dia. (mm)
1 x 1.5 7/0.53 0.7 4.1 0.7 6.4 –
1 x 2.5 7/0.67 0.8 4.5 0.7 6.8 –
1 x 4 7/0.85 0.8 5.0 0.7 7.4 –
1 x 6 7/1.04 0.8 5.6 0.7 7.9 –
1 x 10 7/1.35 1.0 6.9 0.7 8.9 –
1 x 16 7/1.70 1.0 8.0 0.7 9.9 –
1 x 25 7/2.14 1.2 9.6 0.9 11.6 –
1 x 35 7/2.52 1.2 10.8 0.9 12.8 –
1 x 50 19/1.78 1.4 12.7 1.0 14.3 19.7
1 x 70 19/2.14 1.4 14.4 1.1 16.3 21.7
1 x 95 19/2.52 1.6 16.7 1.1 18.4 23.6
1 x 120 37/2.03 1.6 18.2 1.2 20.2 25.4
1 x 150 37/2.25 1.8 20.1 1.4 22.4 28.1
1 x 185 37/2.52 2.0 22.4 1.6 24.7 30.4
1 x 240 61/2.25 2.2 25.4 1.7 27.7 33.4
1 x 300 61/2.52 2.4 28.0 1.8 30.5 36.6
1 x 400 61/2.85 2.6 31.3 2.0 34.1 41.0
1 x 500 61/3.20 2.8 34.8 2.2 37.8 44.7
1 x 630 127/2.52 2.8 38.6 2.4 42.6 49.7
1 x 800 127/2.85 – – 2.6 47.5 55.8
1 x 1000 127/3.20 – – 2.8 52.6 61.5

(Note: For FR-H cables, Cross-Linked LSZH Compound will be used as the insulation material. Further dimensions are available on request.)

Factory Overview


Packaging & Shipping


Fly

Frequently Asked Questions (FAQ)

Q1: What is the difference between FR-H, FR-XH, and FR-XAH?
A:

  • FR-H: Insulated, non-sheathed (typically used for internal wiring where additional protection is not needed).

  • FR-XH: Unarmoured. It includes a LSZH bedding and an LSZH outer sheath for mechanical and environmental protection.

  • FR-XAH: Armoured. It includes all the features of FR-XH plus an Aluminium Wire Armour for the highest level of mechanical protection against impact and rodent damage.

Q2: How do these cables maintain circuit integrity during a fire?
A: These cables use a Mica Tape fire barrier wrapped directly around the copper conductor. When exposed to intense heat, the mica tape turns into a hard, insulating crust that prevents the conductor from short-circuiting, allowing critical systems to remain powered.

Q3: What do the test standards IEC 60331 and BS 6387 mean?
A:

  • IEC 60331 tests a cable’s ability to maintain circuit integrity when subjected to fire (Categories A, B, and C represent different flame temperatures and durations).

  • BS 6387 tests cables under fire conditions for resistance to fire alone (Category C), fire with water (Category W), and fire with mechanical shock (Category Z).

Q4: What is the difference between the XLPE and XLEVA insulation options?
A: Both are excellent insulators, but they have different temperature ratings. XLPE (Cross-linked Polyethylene) is rated for a maximum operating temperature of 90°C, while XLEVA is rated for a higher temperature of 110°C, making it suitable for hotter environments.

Q5: Why are LSZH materials used for the bedding and sheath?
A: LSZH (Low Smoke Zero Halogen) materials are crucial for safety. In a fire, they emit very little smoke (allowing for clear evacuation routes) and do not release toxic, corrosive halogen gases that can damage equipment and harm people.

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Fire Resistant Single Core Cables – FR-H, FR-XH, FR-XAH (Mica Tape, LSZH, 600/1000V)”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS