FRT-XCH Flame Retardant Screened 3-Core + 3E Cable

This flame retardant screened cable is engineered for Variable Speed Drive (VSD) applications with a 3-core plus 3 earth conductor construction. It features plain annealed copper conductors with XLPE insulation and a copper tape/tinned copper wire screen for excellent interference protection. The LSZH outer sheath ensures safety with low smoke, zero halogen, and flame retardant properties. Available in sizes from 1.5mm² to 300mm², it is compliant with IEC 60502 and IEC 60332-3 standards.

This flame retardant screened cable is specifically designed to drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications. Because it is manufactured with plain annealed copper conductors and XLPE insulation, it is exceptionally reliable for demanding industrial power and control circuits. Furthermore, the 3-core plus 3 earth conductor construction provides an additional level of safety and grounding capability. Consequently, these cables are highly suitable for critical installations where both performance and fire safety are paramount.

The cable structure features a plain annealed copper conductor with Class 2 stranding, insulated with XLPE compound. The assembly includes copper tape and tinned copper wire screening, with a compact LSZH sheath for protection. The outer sheath is a robust LSZH (Low Smoke Zero Halogen) compound in black, with insulation colors of red, yellow, blue, green/yellow for easy identification.

Technical Data & Construction Overview:

  • Reference Standard: IEC 60502

  • Test Standard: IEC 60332-3, BS 4066, IEC 60754, BS 6425, IEC 61034, BS 7622-Part-2

  • Voltage Uo/U: 600/1000V

  • Conductor Stranding: Class 2

  • Operating Temperature: (a) Max 90°C for XLPE; (b) Max 110°C for XLEVA

  • Minimum Bending Radius: 10D for unarmoured cable

Construction Data (FRT-XCH)

Size
Nominal Conductor Area (mm²) No. & Dia. of Wires (no./mm) Combined Earth Size (mm²) Radial Thick. of Insulation (mm) Radial Thick. of Sheath (mm) Cable Overall Dia. (mm) Approx. Weight (kg/km)
3 x 1.5 7 / 0.53 4.5 (3 x 1.5) 0.7 1.8 13.6 325
3 x 2.5 7 / 0.67 4.5 (3 x 1.5) 0.7 1.8 14.8 390
3 x 4 7 / 0.85 4.5 (3 x 1.5) 0.7 1.8 15.8 440
3 x 6 7 / 1.04 7.5 (3 x 2.5) 0.7 1.8 16.9 550
3 x 10 7 / 1.35 12 (3 x 4) 0.7 1.8 18.6 760
3 x 16 7 / 1.70 18 (3 x 6) 0.7 1.8 20.8 1000
3 x 25 7 / 2.14 30 (3 x 10) 0.9 1.8 24.0 1470
3 x 35 7 / 2.52 30 (3 x 10) 0.9 1.8 25.6 1890
3 x 50 19 / 1.78 30 (3 x 10) 1.0 1.9 31.1 2300
3 x 70 19 / 2.14 48 (3 x 16) 1.1 2.0 34.6 3000
3 x 95 19 / 2.52 48 (3 x 16) 1.1 2.2 39.3 4200
3 x 120 37 / 2.03 75 (3 x 25) 1.2 2.3 44.0 5400
3 x 150 37 / 2.25 75 (3 x 25) 1.4 2.5 49.0 6400
3 x 185 37 / 2.52 105 (3 x 35) 1.6 2.6 54.0 7900
3 x 240 61 / 2.25 150 (3 x 50) 1.7 2.8 61.0 10200
3 x 300 61 / 2.52 150 (3 x 50) 1.8 3.0 67.0 12300

This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors. With shield conductivity of 1/10th of phase conductor conductivity, this range of VSD cables effectively restrain radiated and conducted radio-frequency emissions. An additional trait of these cables that are designed to be Low Smoke, Zero Halogen and Flame Retardant. Applicable standards include IEC 60754, IEC 60332-3 and IEC 61034.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer (Q:- A:-)

Q:- What is the primary application of the FRT-XCH cable?
A:- It is designed to drastically reduce electrical noise interference in Variable Speed Drive (VSD) applications.
Q:- What type of conductor is used?
A:- It features a plain annealed copper conductor with Class 2 stranding.
Q:- What is the reference standard for this cable?
A:- The reference standard is IEC 60502.
Q:- What is the voltage rating?
A:- The voltage rating is Uo/U 600/1000V.
Q:- What is the maximum operating temperature?
A:- The maximum operating temperature is 90°C for XLPE insulation.
Q:- What is the minimum bending radius?
A:- The minimum bending radius is 10D for unarmoured cable.
Q:- What is the combined earth size for the 3×1.5 cable?
A:- The combined earth size is 4.5 (3 x 1.5) mm².
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of LSZH (Low Smoke Zero Halogen) compound in black.
Q:- Does this cable have fire safety certifications?
A:- Yes, it is designed to be Low Smoke, Zero Halogen, and Flame Retardant, compliant with IEC 60332-3 and IEC 61034.
Q:- What is the cable overall diameter for the 3×1.5 size?
A:- The cable overall diameter is 13.6mm.