3.8/6.6kV Aluminium XLPE 3-Core SWA Heavy Duty Screened Power Cable – AS/NZS 1429.1

The 3.8/6.6kV aluminium XLPE 3-core SWA heavy duty screened power cable is intended for urban electrical distribution networks, industrial facilities and underground power installations. Its specified design incorporates natural TR-XLPE insulation, a heavy duty annealed copper wire screen, steel wire armour and a PVC or PVC/HDPE outer sheath.

Furthermore, it features a rated voltage of 3.8/6.6kV and a maximum operating temperature of 90°C. The heavy duty copper wire screen has a specified minimum fault current rating of 13.1kA for 1 second, subject to the conductor rating and applicable standard requirements.

Application

The 3.8/6.6kV aluminium XLPE 3-core SWA heavy duty screened power cable is designed for primary power supply applications in urban electrical distribution networks, industrial facilities and underground power distribution systems, particularly in systems with high phase-to-earth fault current levels.

Furthermore, the natural TR-XLPE (Tree-Retardant Cross-Linked Polyethylene) insulation provides enhanced resistance to water tree formation and electrical insulation degradation, supporting long-term performance in underground power installations.

In addition, the heavy duty annealed copper wire screen provides a path for earth fault currents, while the steel wire armour indicated in the product title provides additional mechanical protection. The PVC or PVC/HDPE outer sheath provides protection against environmental influences.

These cables are intended for direct burial, underground duct installations, unenclosed installations where they are not subject to mechanical damage, and installations requiring cable gland termination.

Cable Construction

  • Standard: AS/NZS 1429.1:2000.

  • Rated Voltage: 3.8/6.6kV (3800/6600V).

  • Conductor: Aluminium according to the product title; compacted annealed copper according to the construction specification. Confirmation required.

  • Insulation: Natural TR-XLPE (Tree-Retardant Cross-Linked Polyethylene).

  • Number of Cores: 3.

  • Screen: Heavy duty annealed copper wire screen.

  • Armour: SWA (Steel Wire Armour), as indicated in the product title.

  • Outer Sheath: PVC 5V-90 or PVC 5V-90/HDPE.

  • Maximum Operating Temperature: 90°C.

  • Screen Fault Current Rating: Minimum 13.1kA for 1 second, without exceeding the conductor rating, or minimum coverage allowable under the applicable standard.

  • Sheath Marking: Manufacturer’s name (trademark) and type, production year/week or batch number, and metre markings.

  • Special Properties: Tree-retardant insulation, heavy duty copper wire screening and armoured construction.

  • Available Cross-Sections: 16 mm² to 300 mm² per core, subject to confirmation.

  • Installation Methods: Direct burial, underground ducts and suitable unenclosed installations.

Technical Data

The 3.8/6.6kV XLPE 3-core SWA heavy duty screened power cable features a rated voltage of 3800/6600V and a maximum operating temperature of 90°C. Its natural TR-XLPE insulation provides enhanced resistance to water tree formation, supporting long-term electrical insulation performance.

Moreover, the heavy duty annealed copper wire screen features a manufacturer-specified minimum fault current rating of 13.1kA for 1 second, without exceeding the conductor rating, or minimum coverage according to the applicable standard.

The listed conductor cross-sections range from 16 mm² to 300 mm² per core, while the conductor diameter ranges from 4.9 mm to 20.8 mm.

Furthermore, the overall cable diameter ranges from 34.6 mm to 77.7 mm, and the approximate cable mass ranges from 1200 kg/km to 11080 kg/km.

The maximum DC conductor resistance at 20°C ranges from 0.060 Ω/km to 1.150 Ω/km. However, these resistance values are consistent with copper conductors rather than aluminium conductors.

Constructive Data Table

Cross-section (mm²) Conductor No. of Strands Conductor Dia. (mm) Minimum Overall Dia. (mm) Maximum Overall Dia. (mm) Max. DC Resistance at 20°C (Ω/km) Approximate Mass (kg/km)
16 7 4.9 34.6 39.3 1.150 1200
25 7 6.0 37.3 42.0 0.727 1610
35 7 7.0 39.5 44.3 0.524 2020
50 19 8.1 42.1 46.9 0.387 2580
70 19 9.8 45.9 50.7 0.268 3440
95 19 11.4 49.6 54.4 0.193 4460
120 19 12.9 53.2 58.0 0.153 5240
150 19 14.3 56.6 61.5 0.124 6120
185 36 16.0 60.3 65.2 0.099 7250
240 36 18.4 66.2 71.1 0.075 9110
300 36 20.8 72.7 77.7 0.060 11080

Important Technical Note: The original datasheet contains inconsistencies that require confirmation before website publication:

  • The product title specifies aluminium conductors, while the construction specification specifies compacted annealed copper.

  • The conductor resistance values correspond to copper rather than aluminium conductors.

  • The product illustration also appears to show copper conductors.

  • SWA is indicated in the product title, but the armour wire dimensions and bedding construction are not specified separately.

All visible numerical table values have been retained without modification. The correct conductor material, armour construction and corresponding technical specifications must be confirmed before publication.

Factory Overview


Packaging & Shipping


Frequently Asked Questions and Answers

Q:- What is the primary application of the 3.8/6.6kV XLPE 3-core SWA heavy duty screened cable?

A:- It is intended for primary power supply in urban electrical distribution networks, industrial power installations and underground distribution systems, particularly systems with high phase-to-earth fault current requirements.

Q:- What standard does the 3.8/6.6kV XLPE SWA power cable follow?

A:- The manufacturer specifies AS/NZS 1429.1:2000 in the product datasheet.

Q:- What is the rated voltage of the XLPE 3-core SWA heavy duty screened cable?

A:- The rated voltage is 3.8/6.6kV (3800/6600V).

Q:- What is the maximum operating temperature of the XLPE power cable?

A:- The maximum operating temperature is 90°C.

Q:- What type of conductor does the 3.8/6.6kV SWA power cable use?

A:- The product title specifies aluminium conductors, while the construction specification and conductor resistance values indicate compacted annealed copper conductors. The correct conductor material requires technical confirmation.

Q:- What are the advantages of natural TR-XLPE insulation?

A:- Natural TR-XLPE insulation provides enhanced resistance to water tree formation, helping reduce electrical insulation degradation and improve long-term reliability in underground power distribution applications.

Q:- What is the fault current rating of the heavy duty copper wire screen?

A:- The manufacturer specifies a minimum screen fault current rating of 13.1kA for 1 second, without exceeding the conductor rating, or minimum coverage allowable under the applicable standard. The actual rating should be confirmed for the selected cable construction.

Q:- What is the purpose of steel wire armour in medium voltage power cables?

A:- Steel wire armour provides additional mechanical protection against external forces and potential mechanical damage during installation and operation. The specific armour construction for this product requires confirmation.

Q:- What outer sheath materials are available for the XLPE SWA power cable?

A:- The manufacturer specifies PVC 5V-90 or PVC 5V-90/HDPE sheath options. The appropriate sheath construction should be selected according to the installation environment and project requirements.

Q:- Can the 3.8/6.6kV XLPE heavy duty screened cable be installed directly underground?

A:- Yes, the manufacturer identifies direct burial and underground duct installations as suitable applications. However, the final cable construction, mechanical protection and applicable electrical installation requirements must be verified.

Reviews

There are no reviews yet.

Be the first to review “3.8/6.6kV Aluminium XLPE 3-Core SWA Heavy Duty Screened Power Cable – AS/NZS 1429.1”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS