AGKABEL UL AWM Style 2464 Multi-Conductor Cable is a flexible, PVC-insulated and PVC-jacketed control and signal cable recognized under UL 758 (AWM) and commonly certified to CSA standards. Rated at 300V and 80°C, it is available with 2 to 12+ color-coded conductors in sizes from 28 AWG to 16 AWG. Standard constructions feature stranded copper conductors and a flexible PVC jacket, with UL VW-1 / CSA FT1 flame ratings. Shielded variants (foil or braid) are available for EMI protection. Ideal for internal wiring of electronic equipment, control panels, PLC systems, and RS-232/422/485 serial communication, it is the perfect solution for protected, low-voltage signal and control circuits. Not intended for continuous flexing or outdoor exposure.
AGKABEL UL2103 Hook Wire – Multi-Core
High-temperature hookup wire designed for the internal wiring of appliances and electrical equipment. Features Tinned or Bare Copper conductors, Lead-Free SR-PVC insulation, and a Lead-Free PVC sheath. Compliant with UL758, UL1581, and CSA C22.2 No. 210.2. Voltage rating: 300V. Rated temperature: 105°C. Available in AWG sizes 16 to 24, with 2 to 7 cores. Suitable for exposure to oil at temperatures not exceeding 105°C.
AGKABEL GRUPPE LIMITED presents the UL2103 Hook Wire, engineered for reliable performance in the internal wiring of electrical appliances. This multi-core hookup wire is designed to withstand higher temperatures (up to 105°C) and is resistant to oil exposure within that temperature range. The use of Lead-Free SR-PVC insulation and a Lead-Free PVC sheath ensures compliance with environmental standards. It is one of the most popular hookup wires for electric and electronic applications, providing flexibility and durability.
Technical Data
-
Standard: UL758, UL1581, CSA C22.2 NO.210.2
-
Voltage: 300 Volts
-
Conductor: Tinned or bare copper conductor
-
Insulation: Lead free SR-PVC insulation
-
Jacket: Lead free PVC sheath
-
Rated Temperature: 105°C
-
Sheath Marking: Manufacture name (trademark) and type, Production year/week or batch number, Metre-marked
-
Application: Internal wiring of Appliances; or where exposed to oil at a temperature not exceeding 105°C whichever is applicable. The most popular hookup wire for Electric.
Technical Specifications Table
| Conductor (AWG)/Core | No. of strands | Dia. (mm) | Insulation Thick (mm) | Insulation Dia. (mm) | Sheath Thick (mm) | Sheath Dia. (mm) | Max. DC Resistance at 20°C (Ohm/km) |
|---|---|---|---|---|---|---|---|
| 24AWG | |||||||
| 24/2 | 11/0.16 | 0.610 | 0.41 | 1.40 | 0.50 | 3.80 | 94.2 |
| 24/3 | 11/0.16 | 0.610 | 0.41 | 1.40 | 0.60 | 4.20 | 94.2 |
| 24/6 | 11/0.16 | 0.610 | 0.41 | 1.40 | 0.70 | 8.20 | 94.2 |
| 24/7 | 11/0.16 | 0.610 | 0.41 | 1.40 | 0.70 | 8.20 | 94.2 |
| 22AWG | |||||||
| 22/2 | 17/0.16 | 0.760 | 0.41 | 1.60 | 0.60 | 6.00 | 59.4 |
| 22/3 | 17/0.16 | 0.760 | 0.41 | 1.60 | 0.62 | 6.40 | 59.4 |
| 22/6 | 17/0.16 | 0.760 | 0.41 | 1.60 | 0.75 | 8.70 | 59.4 |
| 22/7 | 17/0.16 | 0.760 | 0.41 | 1.60 | 0.75 | 8.70 | 59.4 |
| 20AWG | |||||||
| 20/2 | 26/0.16 | 0.940 | 0.41 | 1.80 | 0.60 | 6.20 | 36.7 |
| 20/3 | 26/0.16 | 0.940 | 0.41 | 1.80 | 0.60 | 6.50 | 36.7 |
| 20/6 | 26/0.16 | 0.940 | 0.41 | 1.80 | 0.75 | 9.00 | 36.7 |
| 20/7 | 26/0.16 | 0.940 | 0.41 | 1.80 | 0.75 | 9.00 | 36.7 |
| 18AWG | |||||||
| 18/2 | 41/0.16 | 1.180 | 0.41 | 2.10 | 0.60 | 6.80 | 23.2 |
| 18/3 | 41/0.16 | 1.180 | 0.41 | 2.10 | 0.63 | 7.30 | 23.2 |
| 18/6 | 41/0.16 | 1.180 | 0.41 | 2.10 | 0.8 | 10.00 | 23.2 |
| 18/7 | 41/0.16 | 1.180 | 0.41 | 2.10 | 0.8 | 10.00 | 23.2 |
| 16AWG | |||||||
| 16/2 | 26/0.254 | 1.49 | 0.42 | 2.40 | 0.65 | 7.50 | 14.6 |
| 16/3 | 26/0.254 | 1.49 | 0.42 | 2.40 | 0.71 | 8.10 | 14.6 |
| 16/6 | 26/0.254 | 1.49 | 0.42 | 2.40 | 0.8 | 10.90 | 14.6 |
| 16/7 | 26/0.254 | 1.49 | 0.42 | 2.40 | 0.8 | 10.90 | 14.6 |
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for this cable?
It is designed for the internal wiring of appliances and electrical equipment. It is also suitable for applications where the wire is exposed to oil at temperatures not exceeding 105°C.
2. What is the maximum temperature rating?
The rated temperature is 105°C.
3. What materials are used for insulation and the jacket?
Both the insulation (SR-PVC) and the jacket (PVC) are lead-free, complying with environmental and safety standards.
4. What standards does this cable comply with?
It complies with UL758, UL1581, and CSA C22.2 NO.210.2.
5. What is the voltage rating of this cable?
The voltage rating is 300 Volts.
6. What sizes and core configurations are available?
Available in AWG sizes 16, 18, 20, 22, and 24, with configurations ranging from 2 to 7 cores.
RELATED PRODUCTS
AGKABEL In-Wall Speaker Wire – CL3R / FPLR, 30V
AGKABEL SJT / SJTO / SJTW-A / SJTOW-A Cables – 300 Volts
AGKABEL XLPE/PVC Three Conductor Shielded MV-90 5kV Cable
Submersible Halogen-Free Flexible Cable (EPDM/Polyurethane) — H05BQ-F & H07BQ-F | EN50525 · VDE0282-10 · IEC 60332-1 | AGKABEL GRUPPE LIMITED
Submersible Halogen-Free Flexible Cables (EPDM/Polyurethane) Built for power cords on machinery, motors, construction sites, and shipyards — and rated for dry, humid, or wet areas plus medium mechanical stress. Halogen-free, flame-retardant, and submersible. Available in 300/500 V and 450/750 V, 0.75–6.0 mm², 2–5 cores.


Reviews
There are no reviews yet.