TPP Local Network Communication Cable (x2x0.4 to x2x0.7)
This local network communication cable is engineered for PABX systems and signal transmission in both underground and interior installations. It features a bare copper conductor with PE insulation and a laminated aluminium tape screen with a copper wire for excellent interference protection. The PE low-density outer sheath ensures durability for demanding network infrastructure. Available in various configurations, it is suitable for fire and explosion hazard locations with proper safety precautions.
These communication cables are primarily used as connecting cables in local networks and PABX systems for telephone purposes and for the transmission of signals. Because they are suitable for underground installations, cable ducts, and conduits, they are highly versatile for both exterior and interior applications. Furthermore, they are suitable for interior installations, provided that the cables are only used in locations with fire and explosion hazards in accordance with the appropriate safety precautions. Consequently, this makes them reliable for structured cabling and network infrastructure projects.
The cable structure features a bare copper conductor with diameters of 0.4 mm, 0.5 mm, 0.6 mm, or 0.7 mm, which is insulated with PE low density. Four wires are twisted into a quad, and 5 quads are twisted in a basic unit. The cable core wrapping consists of several layers of plastic tapes. For screening, an aluminum tape with a thickness of no less than 0.06mm is applied, one side coated with copolymer, followed by a laminated copper wire with a diameter of 0.5mm. Finally, the outer sheath is made of PE low density with 2.5% carbon black.
Technical Data & Construction Overview:
-
Conductor diameter: 0.4 mm / 0.5 mm / 0.6 mm / 0.7 mm
-
Conductor resistance at 20°C-max: 150 Ω/km / 95 Ω/km / 65 Ω/km / 48 Ω/km
-
Insulation resistance – min: 10 GΩ x km
-
Mutual capacitance at 800Hz-nom: 48 nF/km
-
Capacitance unbalances at 800Hz-max: K1: 980 pF/500m; Ke: 1,500 pF/500m; K9-K12: 50% of all values; K9-K12: 300 pF/500m; 20% of all values; 200 pF/500m
-
Test voltage 50Hz, 2 min: 500V / 2000V
-
Operating voltage peak value: 150V / 220V
-
Temperature range: Laying and installing -10°C up to +60°C; Exploitation and storage -40°C up to +60°C
-
Bending radius, min. approx.: 10 x cable diameter
Cable core construction
| Number of pairs | Number of quads | Number of units in the layers | |||||
|---|---|---|---|---|---|---|---|
| 1-st layer | 5×4 | 2-nd layer | 25×4 | 1-st layer | 50×4 | ||
| 6 | 3 | 3-quads | |||||
| 10 | 5 | 5 | |||||
| 20 | 10 | 5 | 5 | ||||
| 30 | 15 | 5 | 10 | ||||
| 50 | 25 | 5 | 7 | 5 | |||
| 100 | 50 | 3 | 6 | ||||
| 150 | 75 | 3 | |||||
| 200 | 100 | 4 | 4 | ||||
| 250 | 125 | 5 | 5 | ||||
| 300 | 150 | 6 | |||||
| 400 | 200 | 8 | |||||
| 500 | 250 | 5 | 5 | ||||
| 600 | 300 | 6 | 6 | ||||
| 700 | 350 | 7 | 7 | ||||
| 800 | 400 | 8 | 8 | ||||
| 1000 | 500 | 10 |
Construction data TPP…x2x0.4
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 2 | 7.4 | 17 | 51 |
| 4 | 8.1 | 17 | 57 |
| 6 | 9.9 | 17 | 91 |
| 10 | 10.7 | 25 | 117 |
| 20 | 15.3 | 51 | 249 |
| 30 | 17.5 | 76 | 324 |
| 50 | 20.2 | 127 | 484 |
| 100 | 24.7 | 254 | 810 |
| 150 | 30.4 | 376 | 1186 |
| 200 | 33.7 | 381 | 1402 |
| 300 | 38.7 | 635 | 1936 |
| 400 | 46.6 | 851 | 2733 |
| 500 | 47.8 | 1276 | 2322 |
| 600 | 50.4 | 1276 | 2813 |
| 700 | 56.0 | 1966 | 3527 |
| 800 | 58.0 | 1966 | 3924 |
| 1000 | 65.0 | 2548 | 4936 |
| 1200 | 65.0 | 3056 | 5447 |
Construction data TPP…x2x0.5
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 2 | 8.1 | 13 | 44 |
| 4 | 9.0 | 21 | 58 |
| 6 | 9.8 | 25 | 74 |
| 10 | 11.3 | 39 | 114 |
| 20 | 15.2 | 76 | 197 |
| 30 | 18.1 | 111 | 281 |
| 50 | 22.5 | 203 | 463 |
| 100 | 32.9 | 387 | 833 |
| 150 | 37.9 | 634 | 1197 |
| 200 | 40.5 | 831 | 1600 |
| 300 | 49.0 | 1276 | 1980 |
| 400 | 51.7 | 1503 | 2500 |
| 500 | 60.5 | 2000 | 3400 |
| 600 | 64.2 | 2400 | 3967 |
| 700 | 68.2 | 2800 | 4593 |
| 800 | 76.3 | 3200 | 5240 |
| 1000 | 76.3 | 3240 | 7387 |
Construction data TPP…x2x0.6
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 2 | 8.3 | 15 | 46 |
| 4 | 9.6 | 25 | 71 |
| 6 | 10.0 | 38 | 90 |
| 10 | 12.1 | 58 | 127 |
| 20 | 17.2 | 113 | 247 |
| 30 | 19.9 | 170 | 332 |
| 50 | 25.6 | 269 | 518 |
| 100 | 35.7 | 531 | 880 |
| 150 | 38.1 | 833 | 1312 |
| 200 | 48.8 | 1133 | 1810 |
| 300 | 54.1 | 1685 | 2785 |
| 400 | 59.3 | 2086 | 3231 |
| 500 | 67.7 | 2500 | 4000 |
| 600 | 72.1 | 3200 | 4807 |
| 700 | 76.3 | 3796 | 5596 |
Construction data TPP…x2x0.7
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 2 | 10.1 | 19 | 107 |
| 4 | 11.9 | 34 | 152 |
| 6 | 12.7 | 48 | 182 |
| 10 | 15.0 | 74 | 227 |
| 20 | 22.0 | 113 | 461 |
| 30 | 25.6 | 165 | 616 |
| 50 | 31.1 | 263 | 1023 |
| 100 | 44.1 | 525 | 1835 |
| 150 | 51.7 | 786 | 2460 |
| 200 | 57.1 | 1119 | 3048 |
| 300 | 68.0 | 1731 | 4640 |
| 400 | 69.3 | 2530 | 5440 |
| 500 | 76.3 | 3240 | 7387 |
Factory Overview

Packaging & Shipping
Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of the TPP cable?
A:- It is used as connecting cables in local networks and PABX systems for telephone and signal transmission.
Q:- Can this cable be installed underground?
A:- Yes, it is suitable for underground installations, cable ducts, and conduits.
Q:- What conductor diameters are available for this cable?
A:- The cable is available with conductor diameters of 0.4 mm, 0.5 mm, 0.6 mm, and 0.7 mm.
Q:- What is the maximum conductor resistance for the 0.4 mm version?
A:- The maximum conductor resistance is 150 Ω/km.
Q:- How is the cable protected against electromagnetic interference?
A:- It features an aluminium tape screen with a laminated copper wire.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is approximately 10 times the cable diameter.
Q:- What is the temperature range for laying and installing?
A:- The laying and installing temperature range is -10°C up to +60°C.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PE low density with 2.5% carbon black.
Q:- How is the color coding structured?
A:- Each unit has a red supporting spiral for counting start and a yellow supporting spiral for counting direction.
Q:- What is the nominal mutual capacitance at 800 Hz?
A:- The nominal mutual capacitance is 48 nF/km.



Reviews
There are no reviews yet.