TZEmPBPBe Low-Frequency Communication Cable for Energetics (x4x0.9)
This low-frequency communication cable is engineered for inter-city networks and automatic telephone exchange connections. It features a 0.9 mm bare copper conductor with paper insulation and a robust bitumen-impregnated paper sheath. Two layers of copper tape screening and steel tape armour provide excellent protection in high electromagnetic fields. The PE low-density outer sheath ensures durability for underground installations in inclined terrains.
These communication cables are specifically designed for the construction of inter-city cable communication networks and connection lines between automatic telephone exchanges, where a transfer of low-frequency signals is required. Because they are suitable for laying in ditches where there is less force of strain and inclined terrain less than 45°, they are highly versatile. Furthermore, they are suitable for areas with higher electro-magnetic fields, and the cables provide higher electric strength with a low reduction factor for energetics. Consequently, this makes them reliable for demanding infrastructure projects.
The cable structure features a bare copper conductor with a diameter of 0.9 mm, which is insulated with paper tape. A paper tape is also used for the quad core cable wrapping, and the quads are twisted into layers. The lead sheath is composed of bitumen and impregnated cable paper with a thickness containing antimony of 0.4 to 0.6 mm. For screening, two layers of copper tapes are applied, followed by an armour protection consisting of two steel tapes and a PE low density with 2.5% carbon black outer sheath.
Technical Data & Construction Overview:
-
Conductor diameter: 0.9 mm
-
Conductor resistance at 20°C: 28.3 Ω/km
-
Insulation resistance: 12 000 MΩ.km
-
Mutual capacitance at 0.8kHz: 34 nF/km
-
Capacitance unbalances at 0.8kHz, max: K1: 280 pF/500m; K9: 100 pF/500m; Ke: 700 pF/500m; K9-K12: 250 pF/500m
-
Test voltage 50Hz, 2 min: Wire/screen 700V; Wire/wire 2000V
-
Operating voltage peak value: 225V
-
Reduction factor, inductive influence by 50Hz, no more than: 0.3 up to 14×0.9; 0.1 over 18×0.9
-
Temperature range: Laying and installing -5°C up to +50°C; Exploitation and storage -40°C up to +70°C
-
Bending radius, min: 20 x D cable
Cable core construction
| Number of quads | Number of quads in the layers | |||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| 3 | 3 | |||
| 4 | 4 | |||
| 7 | 1 | 6 | ||
| 12 | 3 | 9 | ||
| 14 | 1 | 10 | 3 | |
| 19 | 1 | 9 | 12 | |
| 24 | 2 | 8 | 14 | |
| 27 | 3 | 8 | 16 | |
| 30 | 4 | 10 | 16 | |
| 37 | 1 | 6 | 12 | 18 |
Construction data TZEmPBPBe…x4x0.9
| Number of quads | Outer diameter approx. mm | Cable weight approx. kg/km |
|---|---|---|
| 3 | 25.2 | 1537 |
| 4 | 26.3 | 1683 |
| 7 | 29.8 | 2041 |
| 12 | 35.8 | 3205 |
| 14 | 37.0 | 3385 |
| 19 | 39.3 | 3873 |
| 24 | 43.5 | 4498 |
| 27 | 44.5 | 4688 |
| 30 | 46.7 | 4911 |
Color coding
| Side circuit – 1 | Side circuit – 2 | ||
|---|---|---|---|
| a-wire | b-wire | a-wire | b-wire |
| white | red | green | blue |
In each layer there is a quad with a red supporting spiral form which the counting starts and a quad showing the direction of counting with yellow supporting spiral.
Factory Overview
Packaging & Shipping
Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of the TZEmPBPBe cable?
A:- It is used for inter-city communication networks and connections between automatic telephone exchanges.
Q:- Can this cable be installed in inclined terrain?
A:- Yes, it is suitable for inclined terrain of less than 45° where there is less force of strain.
Q:- What is the conductor diameter of this communication cable?
A:- The bare copper conductor has a diameter of 0.9 mm.
Q:- How is the cable protected against electromagnetic interference?
A:- It features two layers of copper tape screening for protection in higher electro-magnetic fields.
Q:- What is the maximum operating voltage peak value?
A:- The operating voltage peak value is 225V.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 20 times the cable diameter (20 x D).
Q:- What is the temperature range for laying and installing?
A:- The laying and installing temperature range is -5°C up to +50°C.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PE low density with 2.5% carbon black.
Q:- How is the quad color coding structured?
A:- Each layer has a quad with a red supporting spiral for counting start and a yellow spiral showing the counting direction.
Q:- What is the mutual capacitance at 0.8 kHz?
A:- The mutual capacitance is 34 nF/km.




Reviews
There are no reviews yet.