SVVn/C 0.6/1 kV Flame Retardant Power Cable – FN KI 02.001-2006

The SVVn/C 0.6/1 kV cable delivers dependable power distribution for industrial and commercial installations. Constructed with copper conductors, PVC insulation, and a black flame retardant PVC outer sheath, it offers exceptional fire safety. Because it meets FN KI 02.001-96 standards, passes the BDS IEC 332-3/C2 Category C flame test, and is RoHS compliant, it provides a safe and reliable solution for environments requiring non-proliferation of flames.

Application
SVVn/C cables provide reliable power transfer and distribution in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they feature flame retardant materials, installers use them in surroundings that require non-proliferation of flames. Furthermore, they ensure safety in industrial and commercial installations where fire risk is a concern. Consequently, they deliver consistent performance and safety in demanding environments.

Cable construction
This cable strictly adheres to FN KI 02.001-96 standards. It features copper solid or twisted wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound according to BDS 5782-84. Finally, a black PVC flame retardant outer sheath of flame retardancy category C protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to BDS 904-84. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 4 kV (alternating) and 12 kV (direct). The temperature range for laying and installing is -5 °C, while the exploitation and storage range is -30 °C to +50 °C. The operating temperature reaches +70 °C. The short circuit temperature is +160 °C for no more than 5 seconds. Installers must respect a minimum bending radius of 10 times the cable diameter. Furthermore, it passes the flame retardant test according to BDS IEC 332-3/C2, Category C.

Color coding
Clear color coding ensures safe and accurate wiring. Conductors without a yellow/green earth core feature random colors for 1 core, light blue and brown for 2 cores, brown, black, and grey for 3 cores, and blue, brown, black, and grey for 4 cores. Conductors with a yellow/green earth core feature yellow/green, blue, and brown for 3 cores, and yellow/green, brown, black, and grey for 4 cores. The neutral conductor is always blue.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SVVn/C 0.6/1 kV

Number of wires and nominal cross-section Form of conductor Cable diameter approx. Mass of Cu Mass of cable approx.
N x mm² mm kg/km kg/km
1 x 1,5 re 7,2 14 69
1 x 2,5 re 7,6 23 82
1 x 4 re 8,0 37 102
1 x 6 re 8,5 55 125
1 x 10 re 9,3 93 178
1 x 16 re 10,8 148 253
1 x 25 rm 11,9 229 350
1 x 35 rm 13,0 322 462
1 x 50 rm 14,2 458 598
1 x 70 rm 16,7 648 810
1 x 95 rm 18,4 885 1100
1 x 120 rm 19,9 1120 1325
1 x 150 rm 21,9 1378 1610
1 x 185 rm 24,3 1703 2010
1 x 240 rm 27,2 2208 2565
1 x 300 rm 30,3 2765 3200
1 x 400 rm 33,6 3680 4010
1 x 500 rm 37,9 4600 5180
2 x 1,0 re 9,3 20 100
2 x 1,5 re 10,0 28 120
2 x 2,5 re 10,6 46 150
2 x 4 re 12,1 75 210
2 x 6 re 13,2 110 260
2 x 10 re 15,2 182 370
2 x 16 rm 17,8 303 558
2 x 25 rm 21,5 470 810
2 x 35 rm 25,2 652 1057
2 x 50 rm 27,0 928 1408
3 x 1,0 re 9,6 28 119
3 x 1,5 re 10,2 42 127
3 x 2,5 re 11,0 69 164
3 x 4 re 12,8 110 250
3 x 6 re 14,0 165 349
3 x 10 re 16,0 275 480
3 x 16 rm 18,9 450 682
3 x 25 rm 22,8 700 1078
3 x 35 rm 25,3 980 1298
3 x 50 rm 28,9 1390 1895
3 x 70 sm 33,0 1963 2400
3 x 95 sm 33,1 2650 3255
3 x 120 sm 35,9 3350 4010
3 x 150 sm 39,3 4185 4830
3 x 185 sm 43,3 5160 6035
3 x 240 sm 48,9 6720 7818
3 x 1,0 + 1,0 re/re 12,0 56 200
3 x 1,5 + 1,5 re/re 13,4 76 235
3 x 4,0 + 2,5 re/re 13,4 132 293
3 x 6,0 + 4,0 re/re 14,4 202 380
3 x 10 + 6,0 re/re 16,7 330 545
3 x 16 + 10 rm/re 19,9 580 810
3 x 25 + 16 rm/re 24,5 850 1245
3 x 35 + 16 rm/rm 27,0 1130 1590
3 x 50 + 25 sm/rm 30,8 1630 2175
3 x 70 + 35 sm/rm 31,8 2280 2785
3 x 95 + 50 sm/rm 36,8 3120 3680
3 x 120 + 70 sm/rm 40,0 4010 5090
3 x 150 + 70 sm/rm 44,3 4850 5620
3 x 185 + 95 sm/rm 49,3 6070 7090
3 x 240 + 120 sm/rm 55,4 7840 9150
4 x 1,5 re 11,0 55 165
4 x 2,5 re 11,9 92 216
4 x 4 re 13,6 146 267
4 x 6 re 15,1 218 363
4 x 10 re 18,4 363 583
4 x 16 rm 20,5 595 951
4 x 25 rm 25,2 970 1285
4 x 35 rm 28,0 1303 1737
4 x 50 sm 32,0 1857 2007
4 x 70 sm 37,3 2601 3101
4 x 95 sm 41,2 4460 5210
4 x 120 sm 45,2 5575 6385
4 x 185 sm 49,5 6790 8800
4 x 240 sm 56,4 8928 10310

Factory Overview



Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SVVn/C cable?
A:- It is used for the transfer and distribution of electrical power in networks with a nominal voltage of 0.6/1 kV, specifically in surroundings requiring non-proliferation of flames.

Q:- What are the key fire safety features of this cable?
A:- It features a black PVC flame retardant outer sheath (Category C), passing the BDS IEC 332-3/C2 flame test.

Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.001-96 standards, and the conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses copper solid or twisted wires (class 1 or 2) with a PVC compound insulation according to BDS 5782-84.

Q:- What is the temperature range for this cable?
A:- The temperature range for laying and installing is -5°C, while the exploitation and storage range is -30°C to +50°C.

Q:- What is the maximum operating and short-circuit temperature?
A:- The operating temperature is +70°C, and the short-circuit temperature is +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV (alternating) and 12 kV (direct).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- What is the neutral conductor color?
A:- The neutral conductor is always blue.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SVVn/C 0.6/1 kV Flame Retardant Power Cable – FN KI 02.001-2006”