PVC/SWA/PVC 0.6/1 kV Armoured Power Cable – BS 6346 Certified

The PVC/SWA/PVC 0.6/1 kV cable delivers dependable power distribution for industrial, domestic, and control applications. Constructed with copper conductors, PVC insulation, galvanized steel wire armour, and a black PVC outer sheath, it offers exceptional mechanical protection. Because it meets BS 6346 standards and is RoHS compliant, it provides a safe and reliable solution for underground and outdoor installations requiring extra protection.

Application
PVC/SWA/PVC cables provide reliable power distribution for industrial and switching installations. They also excel in street lighting and domestic power supply connections. Furthermore, installers use them in secondary distribution networks for interior installation in rooms and cable ducts. Because of their robust design, they are preferred for outdoor applications, open air, and underground installations. Additionally, they function well in water and in areas where mechanical protection against accidental contact or damage is required.

Cable construction
This cable strictly adheres to BS 6346 standards. It features copper wires (class 1 or 2) that comply with BS 6360 (IEC 60228). The insulation uses PVC type TI-1 according to BS 7655, while core identification follows BS 7655. Additionally, a filling compound forms the inner sheath. The cable includes an armour made of galvanized steel wires for superior mechanical strength. Finally, a black PVC compound type TM-1 sheath (acc. BS 7655) protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BS 6360 (IEC 60228) class 1 or 2. The operating temperature reaches a maximum of 70 °C continuous. During a short circuit, it can withstand 250 °C for no more than 5 seconds. It operates at a nominal voltage of 0.6/1 kV and undergoes a test voltage of 3.5 kV. The temperature range for laying, installing, and explosion is -5 °C to +60 °C, while the operating range is -15 °C to +70 °C. Installers must respect a minimum bending radius of 6 times the cable diameter. Furthermore, it passes the flame test according to IEC 332-1.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data PVC/SWA/PVC 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter of cable approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
2 x 1,5 m 11,5 20 273
2 x 1,5 rm 12,2 30 290
2 x 2,5 m 12,9 46 336
2 x 2,5 rm 13,5 46 361
2 x 4,0 m 14,9 77 451
2 x 6,0 rm 16,2 115 543
2 x 10 rm 18,2 183 787
2 x 16 rm 21,9 307 1067
2 x 25 rm 25,3 485 1672
2 x 35 rm 28,5 673 2001
3 x 1,5 m 12,2 43 311
3 x 1,5 rm 12,5 45 321
3 x 2,5 m 13,4 70 372
3 x 2,5 rm 13,9 72 397
3 x 4,0 rm 16,5 115 515
3 x 6,0 m 17,7 173 732
3 x 10 rm 20,8 201 1006
3 x 16 rm 23,6 460 1288
3 x 25 rm 28,0 600 1696
3 x 35 rm 30,1 1010 2410
4 x 1,5 re 12,9 57 344
4 x 1,5 rm 14,3 57 434
4 x 2,5 rm 15,5 93 509
4 x 4,0 m 17,5 154 606
4 x 6,0 m 18,9 230 846
4 x 10 m 22,4 384 1141
4 x 16 m 26,2 614 1721
4 x 25 m 29,0 970 2346
4 x 35 m 32,6 1346 2901

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer

Q:- What is the primary application of the PVC/SWA/PVC cable?
A:- It is used in power plants, industrial and switching installations, street lighting, domestic power supply connections, and secondary distribution networks.

Q:- What standards does the PVC/SWA/PVC cable construction follow?
A:- The construction adheres to BS 6346 standards, and the conductor complies with BS 6360 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses Cu wires class 1 or 2 for the conductor and PVC type TI-1 according to BS 7655 for insulation.

Q:- What kind of armour protects this cable?
A:- The cable features an armour made of galvanized steel wires for robust mechanical protection.

Q:- What is the nominal voltage and test voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and it undergoes a test voltage of 3.5 kV.

Q:- What are the maximum operating and short circuit temperatures?
A:- The maximum continuous operating temperature is 70°C, and it can withstand a short circuit temperature of 250°C for no more than 5 seconds.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 6 times the cable diameter (6 x D cable).

Q:- What are the temperature ranges for installation and operation?
A:- The temperature range for laying, installing, and explosion is -5°C to +60°C, while the operating range is -15°C to +70°C.

Q:- What type of outer sheath protects the cable?
A:- A black PVC compound type TM-1 sheath (according to BS 7655) protects the entire cable assembly.

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to IEC 332-1.

Reviews

There are no reviews yet.

Be the first to review “PVC/SWA/PVC 0.6/1 kV Armoured Power Cable – BS 6346 Certified”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS