SVVn/A 0.6/1 kV Flame Retardant Power Cable – FN KI 02.001

The SVVn/A 0.6/1 kV cable delivers dependable power distribution for industrial and commercial installations. Constructed with copper conductors, PVC insulation, a flame retardant filling, and a black flame retardant PVC outer sheath, it offers exceptional fire safety. Because it meets FN KI 02.001-96 standards, passes the BDS IEC 332-3/C2 Category A flame test, and is RoHS compliant, it provides a safe and reliable solution for environments requiring non-proliferation of flames.

Application
SVVn/A cables provide reliable power transfer and distribution in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they feature flame retardant materials, installers use them in surroundings that require non-proliferation of flames. Furthermore, they ensure safety in industrial and commercial installations where fire risk is a concern. Consequently, they deliver consistent performance and safety in demanding environments.

Cable construction
This cable strictly adheres to FN KI 02.001-96 standards. It features copper solid or twisted wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound according to BDS 5792-84. A filling with flame retardant properties forms the inner sheath. Finally, a black PVC flame retardant outer sheath of flame retardancy category A protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to BDS 904-84. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 4 kV (alternating) and 12 kV (direct). The temperature range for laying, installing, and exploitation is -30 °C to +50 °C. The operating temperature reaches +70 °C. The short circuit temperature is +160 °C for no more than 5 seconds. Installers must respect a minimum bending radius of 10 times the cable diameter. Furthermore, it passes the flame retardant test according to BDS IEC 332-3/C2, Category A.

Color coding
Clear color coding ensures safe and accurate wiring. Conductors without a yellow/green earth core feature random colors for 1 core, brown and blue for 2 cores, brown, black, and blue for 3 cores, and blue, brown, black, and grey for 4 cores. Conductors with a yellow/green earth core feature yellow/green, blue, and brown for 3 cores, and yellow/green, brown, black, and grey for 4 cores. The neutral conductor is always blue.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SVVn/A 0.6/1 kV

Number of wires and nominal cross-section Form of conductor Cable diameter approx. Mass of Cu Mass of cable approx.
N x mm² mm kg/km kg/km
1 x 1,5 re 8,0 14 74
1 x 2,5 re 8,5 23 87
1 x 4,0 re 9,5 37 135
1 x 6,0 re 10,0 55 165
1 x 10 re 11,4 93 221
1 x 16 re 12,5 148 285
1 x 25 re 15,8 225 538
1 x 35 re 17,0 325 642
1 x 50 re 19,1 456 882
1 x 70 re 21,3 648 1225
1 x 95 re 23,6 885 1471
1 x 120 re 25,7 1120 1783
1 x 150 re 28,7 1378 2079
1 x 185 re 31,0 1703 2553
1 x 240 re 36,0 2208 3030
1 x 300 re 39,1 2765 3605
1 x 400 re 38,1 3680 4856
1 x 500 re 46,0 4600 5478
2 x 1,5 re 11,2 28 145
2 x 2,5 re 12,3 46 173
2 x 4,0 re 13,9 75 240
2 x 6,0 re 14,6 112 310
2 x 10 re 17,3 182 523
2 x 16 re 20,2 303 720
2 x 25 re 25,7 652 1256
2 x 35 re 27,7 652 1310
2 x 50 re 32,1 928 1720
2 x 70 re 32,1 1378 2650
2 x 95 re 37,9 1748 3150
3 x 1,5 re 12,3 42 190
3 x 2,5 re 13,3 69 250
3 x 4,0 re 14,3 110 284
3 x 6,0 re 15,9 165 343
3 x 10 re 18,1 275 642
3 x 16 re 20,9 450 820
3 x 25 re 25,7 700 1320
3 x 35 re 26,7 980 1738
3 x 50 re 30,2 1410 2435
3 x 70 re 31,2 1850 2823
3 x 95 re 38,0 2550 4098
3 x 120 re 38,0 3350 5345
3 x 150 re 41,6 4530 6655
3 x 185 re 48,0 5160 6860
3 x 240 re 51,4 6720 8000
3 x 1,5 + 1,5 re/re 13,2 56 235
3 x 4,0 + 2,5 re/re 15,8 132 435
3 x 6,0 + 4,0 re/re 18,8 202 536
3 x 10 + 6,0 re/re 21,8 330 738
3 x 16 + 10 re/re 23,0 549 1068
3 x 25 + 16 rm/re 27,0 850 1470
3 x 35 + 16 rm/rm 29,2 1131 1578
3 x 50 + 25 sm/rm 33,2 1680 2505
3 x 70 + 35 sm/rm 38,0 2280 2833
3 x 95 + 50 sm/rm 40,0 3090 4315
3 x 120 + 70 sm/rm 43,2 4010 5180
3 x 150 + 70 sm/rm 47,2 4880 5840
3 x 185 + 95 sm/rm 52,3 6070 7771
3 x 240 + 120 sm/rm 56,6 7840 9254
3 x 300 + 150 sm/rm 64,3 9928 12666
4 x 1,5 re 12,9 55 270
4 x 4,0 re 16,2 146 454

Construction data SVVn/A 0.6/1 kV

Number of wires and nominal cross-section Form of conductor Cable diameter approx. Mass of Cu Mass of cable approx.
N x mm² mm kg/km kg/km
4 x 6,0 re 17,4 218 569
4 x 10 re 18,2 363 710
4 x 16 re 21,8 582 1162
4 x 25 rm 28,0 930 1873
4 x 35 rm 30,1 1303 2190
4 x 50 sm 36,1 1837 2937
4 x 70 sm 38,1 2650 3397
4 x 95 sm 42,0 3620 4638
4 x 120 sm 45,2 4628 5504
4 x 150 sm 51,7 3554 6669
4 x 185 sm 55,0 3846 6885
4 x 240 sm 63,7 5848 8138
4 x 300 sm 64,4 11060 13722

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SVVn/A cable?
A:- It is used for the transfer and distribution of electrical power in networks with a nominal voltage of 0.6/1 kV, specifically in surroundings requiring non-proliferation of flames.

Q:- What are the key fire safety features of this cable?
A:- It features a filling with flame retardant properties and a black PVC flame retardant outer sheath (Category A), passing the BDS IEC 332-3/C2 flame test.

Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.001-96 standards, and the conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses copper solid or twisted wires (class 1 or 2) with a PVC compound insulation according to BDS 5792-84.

Q:- What is the temperature range for this cable?
A:- The temperature range for laying and exploitation is -30°C to +50°C.

Q:- What is the maximum operating and short-circuit temperature?
A:- The operating temperature is +70°C, and the short-circuit temperature is +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV (alternating) and 12 kV (direct).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- What is the neutral conductor color?
A:- The neutral conductor is always blue.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SVVn/A 0.6/1 kV Flame Retardant Power Cable – FN KI 02.001”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS