2XS2Y & A2XS2Y 3.6/6 kV to 20/35 kV XLPE Medium Voltage Cable – IEC 60502-2

The 2XS2Y and A2XS2Y cables deliver dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, and a black PE outer sheath, they offer excellent thermal and electrical protection for 3.6/6 kV, 8.7/15 kV, and 20/35 kV applications. Because they meet IEC 60502-2 standards and are RoHS compliant, they provide a safe and reliable solution for urban networks, substations, and industrial plants.

Application
2XS2Y and A2XS2Y medium voltage cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with nominal voltages of Uo/U 3.6/6 kV, 8.7/15 kV, and 20/35 kV, and a frequency of 50 Hz, in urban and district electrical networks. Furthermore, installers use them for the electrical supply of transformer substations, small and medium industrial plants, and power stations. Because of their robust design, they are suitable for fixed assembly in lines with unlimited difference levels, indoor installations, cable ducts, conduits, and shafts. Additionally, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters.

Cable construction
This cable strictly adheres to IEC 60502-2 standards. It features copper and aluminum stranded compacted conductors according to IEC 60228 class 2. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. The metal screen consists of copper wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm. A layer of plastic tape forms the separating layer. The sheath uses PE compound type ST7 according to IEC 60502. The color is black. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS904 (IEC60228) class 2. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at nominal voltages of 3.6/6, 8.7/15, and 20/35 kV, while the highest system voltage Uo/U is not more than 3.6/6, 12/20, and 24/36 kV. Test voltage is AC (+) – 5 min for 3.6/6 kV (10 kV), 8.7/15 kV (30 kV), and 20/35 kV (48 kV), or DC (-) – 15 min. The level of partial discharge at 2Uo is max. 5 pC. The minimum bending radius is 15 times the cable diameter. The minimum temperature of laying is no less than -20 °C. The temperature of explosion is -30 to 50 °C. Testing follows IEC 60502-2 and DIN VDE 0276-620. The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of conductors in mm.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XS2Y, A2XS2Y 3.6/6; 7.5/15; 20/35 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Nominal cross section of screen Cable diameter approx. 2XS2Y Mass of Cu approx. 2XS2Y Mass of cable approx. A2XS2Y Mass of Al approx. A2XS2Y Mass of cable approx.
N x mm² mm mm mm² mm kg/km kg/km kg/km kg/km
3.6/6 kV
1x35m/16 2,5 1,8 16 21,0 493 754 94 176
1x50m/16 2,5 1,8 16 22,1 604 865 127 581
1x70m/16 2,5 1,8 16 23,7 793 1054 183 638
1x95m/16 2,5 1,8 16 25,5 1033 1381 251 746
1x120m/16 2,5 1,8 16 26,9 1255 1630 321 772
1x150m/16 2,5 1,8 16 28,6 1537 1942 384 872
1x185m/25 2,6 2,0 25 30,8 1942 2599 494 950
1x240m/25 2,6 2,0 25 33,1 2365 2879 495 1258
1x300m/25 2,8 2,0 25 36,1 2879 2879 649 1340
1x400m/35 2,8 2,2 35 39,7 2730 3537 695 1232
1x500m/35 3,0 2,3 35 43,0 3693 3670 1095 1557
1x630m/35 3,2 2,4 35 43,9 4807 5609 1374 2480
8.7/15 kV
1x35m/16 4,5 1,8 16 25,0 493 881 94 176
1x50m/16 4,5 1,8 16 26,1 604 1019 127 658
1x70m/16 4,5 1,8 16 27,8 793 1266 183 718
1x95m/16 4,5 1,9 16 29,7 1033 1520 251 840
1x120m/16 4,5 1,9 16 31,2 1255 1896 321 880
1x150m/16 4,5 2,0 16 32,8 1537 2107 384 1006
1x185m/16 4,5 2,1 16 34,7 1850 2193 494 1162
1x240m/16 4,5 2,2 16 37,3 2365 2829 649 1329
1x300m/25 4,5 2,3 25 39,8 2835 3055 812 1450
1x400m/35 4,5 2,5 35 43,6 3240 4102 1095 1826
1x500m/35 4,5 2,5 35 46,7 4807 4087 1374 2562
1x630m/35 4,5 2,5 35 47,6 4807 4877 1374 2649
20/35 kV
1x50m/16 8,8 2,1 16 35,3 604 1416 127 1115
1x70m/16 8,8 2,1 16 37,0 793 1681 183 1275
1x95m/16 8,8 2,2 16 38,9 1033 1955 251 1334
1x120m/16 8,8 2,3 16 40,5 1255 2276 321 1384
1x150m/16 8,8 2,3 16 42,0 1537 2284 384 1518
1x185m/25 8,8 2,4 25 43,9 1930 2557 494 1631
1x240m/25 8,8 2,5 25 46,3 2454 2930 649 1912
1x300m/25 8,8 2,5 25 48,8 2480 2847 812 2150
1x400m/35 8,8 2,6 35 52,3 3733 3819 1093 2490
1x500m/35 8,8 2,8 35 55,9 4807 6433 1374 3315

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XS2Y and A2XS2Y cables?
A:- They are designed for the transfer and distribution of electrical power in urban and district electrical networks and for the electrical supply of transformer substations, small and medium industrial plants, and power stations.

Q:- What are the nominal voltage levels available for this cable?
A:- The cables are available in three nominal voltage levels: Uo/U 3.6/6 kV, 8.7/15 kV, and 20/35 kV, operating at a frequency of 50 Hz.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-2 standards, and the conductor complies with IEC 60228 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu and Al stranded compacted conductors with XLPE insulation.

Q:- What type of metal screen is used in the cable?
A:- The metal screen consists of copper wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the maximum partial discharge level?
A:- The level of partial discharge at 2Uo is max. 5 pC.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The minimum temperature of laying is no less than -20°C, and the temperature of explosion is -30 to 50°C.

Q:- What is the maximum force of strain during laying?
A:- The maximum force of strain is 30NS for Al cores and 50NS for Cu cores, where N is the number of cores and S is the cross-section of conductors in mm.

Reviews

There are no reviews yet.

Be the first to review “2XS2Y & A2XS2Y 3.6/6 kV to 20/35 kV XLPE Medium Voltage Cable – IEC 60502-2”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS