SVOBT Up to 1 kV Copper Conductor Lead Sheathed Steel Tape Armoured Cable – BDS 11303-83
The SVOBT up to 1 kV cable is specially designed for railway signalling systems, automatic control systems, and railway block systems. Manufactured according to BDS 11303-83, it features Class 1 copper conductors, PVC insulation, PVC filling, a lead (Pb) sheath, a thermoplastic inner sheath, steel tape armour, and a protective PVC outer sheath. With a maximum operating temperature of +70°C and a specified temperature range of -25°C to +50°C, it provides a reliable solution for railway electrical and signalling infrastructure.
Application
SVOBT cables are specially designed for use in railway signalling systems, automatic control systems, and railway block systems. They provide reliable electrical connections for railway transportation infrastructure and signalling installations. These cables are manufactured for applications with nominal voltages up to 1 kV and are suitable for demanding railway environments.
Cable Construction
The SVOBT cable is manufactured according to BDS 11303-83 standards.
-
Conductor: Single-core copper conductor, Class 1, according to BDS 904-84.
-
Insulation: PVC compound according to BDS 5792-84.
-
Insulation colour: According to BDS 11303-83.
-
Filling: PVC compound.
-
Lead sheath: Lead (Pb) sheath according to BDS 4712-84.
-
Inner sheath: Thermoplastic material.
-
Armour: Steel tapes.
-
Outer sheath: PVC compound according to BDS 5792-84.
-
Outer sheath colour: Grey.
Technical Data
| Parameter | Specification |
|---|---|
| Applicable standard | BDS 11303-83 |
| Conductor standard | BDS 904-84, Class 1 |
| Conductor material | Copper |
| Conductor resistance at 20°C | According to BDS 11303-83 |
| Maximum operating temperature | +70°C |
| Nominal voltage | Up to 1 kV |
| Test voltage | AC 4 kV, 50 Hz |
| Operating temperature range | -25°C to +50°C |
| Minimum bending radius (fixed installation) | 15 × D (cable diameter) |
| Testing standard | BDS 11303-83 |
| Outer sheath colour | Grey |
Conductor and Cable Construction Identification
| Component | Description |
|---|---|
| Conductor | Copper |
| Conductor class | Class 1 |
| Insulation | PVC |
| Filling | PVC compound |
| Lead sheath | Pb |
| Inner sheath | Thermoplastic material |
| Armour | Steel tapes |
| Outer sheath | PVC |
Color Coding
According to the supplied product specification:
-
3-core: Brown, black, grey; or yellow/green, blue, and brown.
-
4-core: Blue, brown, black, grey; or yellow/green, brown, black, and grey.
-
5-core: Blue, brown, black, grey, black; or yellow/green, blue, brown, black, and grey.
-
Multiple-core: Black cores with number markings, or black cores with number markings and a yellow/green core in the outer cover.
The insulation colours are specified according to BDS 11303-83.
3. Construction Data Tables
The following construction data is transcribed from your supplied SVOBT product specification.
-
Outer cable diameter: mm
-
Copper weight: kg/km
-
Approximate cable weight: kg/km
Construction Data – SVOBT Up to 1 kV
| Number of conductors and nominal cross-section (N × mm²) | Outer diameter approx. (mm) | Copper weight (kg/km) | Cable weight approx. (kg/km) |
|---|---|---|---|
| 3 × 1.5 | 18.0 | 42 | 840 |
| 3 × 2.5 | 19.5 | 70 | 960 |
| 4 × 1.5 | 17.7 | 55 | 850 |
| 4 × 2.5 | 19.8 | 92 | 1050 |
| 4 × 4.0 | 21.0 | 146 | 1220 |
| 5 × 1.5 | 18.8 | 70 | 960 |
| 6 × 1.5 | 19.6 | 85 | 1052 |
| 7 × 1.5 | 19.6 | 98 | 1068 |
| 7 × 2.5 | 21.5 | 160 | 1290 |
| 8 × 1.5 | 20.6 | 110 | 1140 |
| 8 × 4.0 | 25.0 | 280 | 1700 |
| 10 × 1.5 | 22.8 | 140 | 1360 |
| 10 × 4.0 | 28.4 | 365 | 2150 |
| 12 × 1.5 | 23.4 | 165 | 1450 |
| 14 × 1.5 | 24.0 | 195 | 1550 |
| 14 × 2.5 | 27.0 | 320 | 1900 |
| 16 × 1.5 | 25.0 | 220 | 1650 |
| 19 × 1.5 | 25.9 | 260 | 1765 |
| 19 × 2.5 | 29.3 | 435 | 2300 |
| 24 × 1.5 | 29.3 | 330 | 2185 |
| 24 × 2.5 | 33.5 | 546 | 2870 |
| 30 × 1.5 | 30.7 | 410 | 2435 |
| 30 × 2.5 | 35.0 | 685 | 3200 |
| 37 × 1.5 | 32.7 | 506 | 2850 |
Factory Overview
Packaging & Shipping
Frequently Asked Questions (FAQ)
Q:- What is the primary application of SVOBT cable?
A:- SVOBT cables are primarily used in railway signalling systems, automatic control systems, and railway block systems.
Q:- What standard does SVOBT cable follow?
A:- The cable is manufactured according to BDS 11303-83.
Q:- What type of conductor is used in SVOBT cable?
A:- It uses copper conductors, Class 1, according to BDS 904-84.
Q:- What insulation material is used in SVOBT cable?
A:- It uses PVC compound insulation according to BDS 5792-84.
Q:- Does SVOBT cable have a lead sheath?
A:- Yes. It includes a lead (Pb) sheath according to BDS 4712-84, providing an additional protective layer within the cable construction.
Q:- What type of armour is used in SVOBT cable?
A:- The cable uses steel tape armour to provide additional mechanical protection.
Q:- What is the nominal voltage of SVOBT cable?
A:- The cable is designed for nominal voltages up to 1 kV.
Q:- What is the maximum operating temperature?
A:- The maximum operating temperature is +70°C.
Q:- What is the operating temperature range?
A:- The specified operating temperature range is -25°C to +50°C.
Q:- What is the minimum bending radius of SVOBT cable?
A:- For fixed installations, the minimum bending radius is 15 times the cable diameter (15 × D).




Reviews