SVOBT Up to 1 kV Copper Conductor Lead Sheathed Steel Tape Armoured Cable – BDS 11303-83

The SVOBT up to 1 kV cable is specially designed for railway signalling systems, automatic control systems, and railway block systems. Manufactured according to BDS 11303-83, it features Class 1 copper conductors, PVC insulation, PVC filling, a lead (Pb) sheath, a thermoplastic inner sheath, steel tape armour, and a protective PVC outer sheath. With a maximum operating temperature of +70°C and a specified temperature range of -25°C to +50°C, it provides a reliable solution for railway electrical and signalling infrastructure.

Application

SVOBT cables are specially designed for use in railway signalling systems, automatic control systems, and railway block systems. They provide reliable electrical connections for railway transportation infrastructure and signalling installations. These cables are manufactured for applications with nominal voltages up to 1 kV and are suitable for demanding railway environments.

Cable Construction

The SVOBT cable is manufactured according to BDS 11303-83 standards.

  • Conductor: Single-core copper conductor, Class 1, according to BDS 904-84.

  • Insulation: PVC compound according to BDS 5792-84.

  • Insulation colour: According to BDS 11303-83.

  • Filling: PVC compound.

  • Lead sheath: Lead (Pb) sheath according to BDS 4712-84.

  • Inner sheath: Thermoplastic material.

  • Armour: Steel tapes.

  • Outer sheath: PVC compound according to BDS 5792-84.

  • Outer sheath colour: Grey.

Technical Data

Parameter Specification
Applicable standard BDS 11303-83
Conductor standard BDS 904-84, Class 1
Conductor material Copper
Conductor resistance at 20°C According to BDS 11303-83
Maximum operating temperature +70°C
Nominal voltage Up to 1 kV
Test voltage AC 4 kV, 50 Hz
Operating temperature range -25°C to +50°C
Minimum bending radius (fixed installation) 15 × D (cable diameter)
Testing standard BDS 11303-83
Outer sheath colour Grey

Conductor and Cable Construction Identification

Component Description
Conductor Copper
Conductor class Class 1
Insulation PVC
Filling PVC compound
Lead sheath Pb
Inner sheath Thermoplastic material
Armour Steel tapes
Outer sheath PVC

Color Coding

According to the supplied product specification:

  • 3-core: Brown, black, grey; or yellow/green, blue, and brown.

  • 4-core: Blue, brown, black, grey; or yellow/green, brown, black, and grey.

  • 5-core: Blue, brown, black, grey, black; or yellow/green, blue, brown, black, and grey.

  • Multiple-core: Black cores with number markings, or black cores with number markings and a yellow/green core in the outer cover.

The insulation colours are specified according to BDS 11303-83.

3. Construction Data Tables

The following construction data is transcribed from your supplied SVOBT product specification.

  • Outer cable diameter: mm

  • Copper weight: kg/km

  • Approximate cable weight: kg/km

Construction Data – SVOBT Up to 1 kV

Number of conductors and nominal cross-section (N × mm²) Outer diameter approx. (mm) Copper weight (kg/km) Cable weight approx. (kg/km)
3 × 1.5 18.0 42 840
3 × 2.5 19.5 70 960
4 × 1.5 17.7 55 850
4 × 2.5 19.8 92 1050
4 × 4.0 21.0 146 1220
5 × 1.5 18.8 70 960
6 × 1.5 19.6 85 1052
7 × 1.5 19.6 98 1068
7 × 2.5 21.5 160 1290
8 × 1.5 20.6 110 1140
8 × 4.0 25.0 280 1700
10 × 1.5 22.8 140 1360
10 × 4.0 28.4 365 2150
12 × 1.5 23.4 165 1450
14 × 1.5 24.0 195 1550
14 × 2.5 27.0 320 1900
16 × 1.5 25.0 220 1650
19 × 1.5 25.9 260 1765
19 × 2.5 29.3 435 2300
24 × 1.5 29.3 330 2185
24 × 2.5 33.5 546 2870
30 × 1.5 30.7 410 2435
30 × 2.5 35.0 685 3200
37 × 1.5 32.7 506 2850

Factory Overview


Packaging & Shipping


Frequently Asked Questions (FAQ)

Q:- What is the primary application of SVOBT cable?

A:- SVOBT cables are primarily used in railway signalling systems, automatic control systems, and railway block systems.

Q:- What standard does SVOBT cable follow?

A:- The cable is manufactured according to BDS 11303-83.

Q:- What type of conductor is used in SVOBT cable?

A:- It uses copper conductors, Class 1, according to BDS 904-84.

Q:- What insulation material is used in SVOBT cable?

A:- It uses PVC compound insulation according to BDS 5792-84.

Q:- Does SVOBT cable have a lead sheath?

A:- Yes. It includes a lead (Pb) sheath according to BDS 4712-84, providing an additional protective layer within the cable construction.

Q:- What type of armour is used in SVOBT cable?

A:- The cable uses steel tape armour to provide additional mechanical protection.

Q:- What is the nominal voltage of SVOBT cable?

A:- The cable is designed for nominal voltages up to 1 kV.

Q:- What is the maximum operating temperature?

A:- The maximum operating temperature is +70°C.

Q:- What is the operating temperature range?

A:- The specified operating temperature range is -25°C to +50°C.

Q:- What is the minimum bending radius of SVOBT cable?

A:- For fixed installations, the minimum bending radius is 15 times the cable diameter (15 × D).

Reviews

There are no reviews yet.

Be the first to review “SVOBT Up to 1 kV Copper Conductor Lead Sheathed Steel Tape Armoured Cable – BDS 11303-83”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS