FLRYW PVC Automotive Cable – Hot-Pressure Resistant (DBL 6312)
The FLRYW cable delivers dependable electrical connections for high-temperature automotive applications. Constructed with tinned or bare copper conductors and specialized heat-resistant PVC insulation, it offers excellent conductivity, corrosion resistance, and thermal stability. Because it meets DBL 6312 standards and passes hot-pressure testing, it provides a safe and reliable solution for wiring inside engine compartments.
Application
FLRYW cables provide reliable electrical connections for high-temperature automotive applications. Because they feature a tinned or bare copper conductor and specialized heat-resistant PVC insulation, installers use them in areas subjected to elevated thermal stress. Furthermore, these cables successfully pass a hot-pressure resistance test at 120 °C, making them highly suitable for applications inside the engine compartment. Consequently, they deliver consistent and safe performance in the most demanding vehicle environments.
Cable construction
This cable strictly adheres to DBL 6312 standards. It features a tinned or bare copper conductor (concentric construction) for maximum conductivity and corrosion resistance. The insulation uses a specialized plasticized PVC compound designed to withstand high temperatures. The sheath is marked with the manufacturer’s name or trademark, product type, production year/week or batch number, and metre markings.
Technical Data
The cable delivers consistent performance under specific conditions. The rated temperature range is -40 °C to +105 °C. The maximum conductor resistance at 20 °C varies by cross-section, ranging from 52.0/54.5 Ω/m for the 0.35 mm² cable to 0.743/0.757 Ω/m for the 25 mm² cable.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
| Cross-section | Conductor | Insulation | Max. Cond. Resistance at 20°C | Weight | ||
|---|---|---|---|---|---|---|
| mm² | No./mm | OD.(mm) | Thick. (mm) | OD. (mm) | Bare/Tinned Ω/m | Kg/km |
| 0.35 | 7/0.25 | 0.8 | 0.2 | 1.4 | 52.0/54.5 | 4.5 |
| 0.35 | 12/0.2 | 0.90 | 0.20 | 1.4 | 52.0/54.5 | 4.5 |
| 0.5 | 16/0.2 | 1.00 | 0.22 | 1.6 | 37.1/38.2 | 6.6 |
| 0.75 | 24/0.2 | 1.20 | 0.24 | 1.9 | 24.7/25.4 | 9.0 |
| 1 | 32/0.2 | 1.35 | 0.24 | 2.1 | 18.5/19.1 | 11.0 |
| 1.5 | 30/0.25 | 1.70 | 0.24 | 2.4 | 12.7/13.0 | 16 |
| 2 | 30/0.3 | 2.00 | 0.28 | 2.8 | 9.42/9.69 | 22.5 |
| 2.5 | 50/0.25 | 2.20 | 0.28 | 3 | 7.6/7.8 | 26 |
| 3 | 45/0.3 | 2.40 | 0.28 | 3.2 | 6.15/6.36 | 33.5 |
| 4 | 56/0.3 | 2.75 | 0.32 | 3.7 | 4.7/4.8 | 42 |
| 6 | 84/0.3 | 3.30 | 0.32 | 4.3 | 3.1/3.2 | 61 |
| 10 | 80/0.4 | 4.50 | 0.48 | 6 | 1.82/1.85 | 108 |
| 16 | 126/0.4 | 6.30 | 0.52 | 7.9 | 1.16/1.18 | 170 |
| 25 | 196/0.4 | 7.80 | 0.52 | 9.4 | 0.743/0.757 | 265 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the FLRYW cable?
A:- It is designed for high-temperature automotive applications, specifically inside the engine compartment.
Q:- What standards does this cable comply with?
A:- It complies with DBL 6312 standards.
Q:- What is the rated temperature range?
A:- The rated temperature range is -40°C to +105°C, and it passes a hot-pressure resistance test at 120°C.
Q:- What type of conductor and insulation does it use?
A:- It uses tinned or bare copper conductors with specialized heat-resistant plasticized PVC insulation.
Q:- What is the benefit of the tinned construction?
A:- The tinned construction provides enhanced corrosion resistance and durability compared to bare copper.
Q:- What is the maximum conductor resistance for the 0.35 mm² cable?
A:- The maximum conductor resistance for the 0.35 mm² cable is 52.0/54.5 Ω/m at 20°C.
Q:- What is the maximum conductor resistance for the 25 mm² cable?
A:- The maximum conductor resistance for the 25 mm² cable is 0.743/0.757 Ω/m at 20°C.
Q:- What information is included in the sheath marking?
A:- The sheath marking includes the manufacturer’s name/trademark, product type, production year/week or batch number, and metre markings.
Q:- What is the smallest cross-section available in the provided table?
A:- The smallest cross-section shown is 0.35 mm².
Q:- Are other dimensions available besides those listed?
A:- Yes, further dimensions are available upon request.
RELATED PRODUCTS
AGKABEL Electrical Vehicle Charging Cables – Type EVT (600V) & EVJT (300V)
AGKABEL Electrical Vehicle Charging Cables – Type EVT & EVJT (UL62)
AGKABEL Electrical Vehicle Charging Cables – Type EVT (600V) & EVJT (300V)
-
Standards: UL62 certified, NEC Article 400 compliant for indoor/outdoor use.
-
Durability: High-performance Thermoplastic Elastomer (TPE) insulation and jacket for extreme flexibility and abrasion resistance.
-
Temperature Range: Operates in harsh conditions from -50°C to 105°C.
-
Resistance: Excellent resistance to heat aging, chemicals, solvents, oil, and cold.
-
Configurations: 3C+1C construction. EVT available from 14 AWG to 2 AWG (600V); EVJT available in 14 AWG and 12 AWG (300V).




Reviews