AGKABEL Fire Resistant Cables (FR-XL & FR-XSL) are 300/500V safety cables designed to maintain circuit integrity during a fire, ensuring that critical emergency systems remain powered. Available in 1-core to 4-core configurations, they feature a Mica Tape fire barrier wrapped around plain annealed copper conductors, with a choice of XLPE (90°C) or XLEVA (110°C) insulation. The cables utilize LSZH (Low Smoke Zero Halogen) bedding and an orange outer sheath for maximum safety and low toxicity. For areas requiring superior mechanical protection, the FR-XSL variant includes a Galvanized Steel Wire Armour. Fully compliant with IEC 60331 and BS 6387, these cables are the reliable choice for fire alarms, emergency lighting, and critical control circuits.
AGKABEL Fire Resistant Instrumentation Cables – FR-XlOL (Unarmoured) & FR-XlOSL (Armoured) – Individually & Overall Screened
AGKABEL Fire Resistant Instrumentation Cables (FR-XlOL & FR-XlOSL) are advanced, double-screened multi-pair cables designed for mission-critical environments where signal integrity and fire survival are paramount. Featuring both individual pair screening and an overall screen, they provide unmatched protection against electromagnetic interference (EMI) and crosstalk. Built with a Mica Tape fire barrier, XLPE or XLEVA insulation, and a Low Smoke Zero Halogen (LSZH) sheath, these cables ensure continuous operation during a fire. Available in an unarmoured (FR-XlOL) or Galvanized Steel Wire Armoured (FR-XlOSL) design, they are fully compliant with IEC 60331, BS 5308, and BS 7629 standards.
AGKABEL GRUPPE LIMITED presents the FR-XlOL and FR-XlOSL series of Fire Resistant Instrumentation Cables, the ultimate solution for critical control systems that demand both fire survival and uncompromised signal integrity. Designed for complex industrial environments, these multi-pair cables feature a sophisticated double-screening design: each individual pair is wrapped in an Aluminium/Polyester tape, followed by an overall Aluminium/Polyester tape screen. Both screens include a 0.5mm² Tinned Drain Wire. This dual-layer protection completely eliminates crosstalk between pairs and shields against external electromagnetic interference (EMI).
At the heart of the cable is a Mica Tape fire barrier wrapped around Plain Annealed Copper (Class 2) conductors. When exposed to intense heat, the mica forms a ceramic-like crust, preventing short circuits and ensuring emergency systems remain operational. Insulation options include XLPE (90°C) or XLEVA (110°C), and the cable is sheathed in LSZH (Low Smoke Zero Halogen) compounds for maximum safety during a fire. The FR-XlOL variant is unarmoured, while the FR-XlOSL features a robust Galvanized Steel Wire Armour for severe mechanical protection.
Technical Data
-
Conductor: Plain Annealed Copper (Class 2 Stranding)
-
Fire Barrier: Mica Tape
-
Insulation: (a) XLPE Compound or (b) XLEVA Compound
-
Individual Screen: Aluminium/Polyester Tape with 0.5mm² (7/0.3mm) Tinned Drain Wire
-
Overall Screen: Aluminium/Polyester Tape with 0.5mm² (7/0.3mm) Tinned Drain Wire
-
Bedding: LSZH Compound
-
Armouring: Galvanized Steel Wire (FR-XlOSL only)
-
Sheath: LSZH Compound (Orange)
-
Colour: Insulation – White and Black with numberings.
-
Reference Standard: IEC 60502 / BS 5308 / BS 7629
-
Test Standards: IEC 60331 (Cat A, B, C), BS 6387 (C, W, Z), SS299 (C, W, Z), IEC 60332-3, BS 4066, IEC 60754, BS 6425, IEC 61034, BS 7622-Part 2.
-
Voltage Uo/U: 300/500V
-
Operating Temperature: (a) Max 90°C for XLPE, (b) Max 110°C for XLEVA.
-
Minimum Bending Radius: 8D for unarmoured, 10D for armoured.
Technical Specifications Table
| Nominal Conductor Area (mm²) | No. & Diameter of Wires (no./mm) | Radial Thick. of Insulation (mm) | FR-XlOL Cable Overall Dia. (mm) | FR-XlOL Approx. Weight (kg/km) | FR-XlOSL Dia. Under Armour (mm) | FR-XlOSL Armour Wire Dia. (mm) | FR-XlOSL Cable Overall Dia. (mm) | FR-XlOSL Approx. Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| 2 Pairs | ||||||||
| 2P x 1.0 | 7 / 0.43 | 0.6 | 15.2 | 166 | 15.2 | 0.90 | 20.0 | 555 |
| 2P x 1.5 | 7 / 0.53 | 0.7 | 17.0 | 205 | 17.0 | 1.25 | 22.7 | 769 |
| 2P x 2.5 | 7 / 0.67 | 0.8 | 19.2 | 350 | 19.2 | 1.25 | 24.9 | 938 |
| 5 Pairs | ||||||||
| 5P x 1.0 | 7 / 0.43 | 0.6 | 17.5 | 335 | 17.5 | 1.25 | 23.2 | 1000 |
| 5P x 1.5 | 7 / 0.53 | 0.7 | 21.5 | 433 | 21.5 | 1.60 | 28.1 | 1352 |
| 5P x 2.5 | 7 / 0.67 | 0.8 | 24.0 | 592 | 24.0 | 1.60 | 30.8 | 1665 |
| 10 Pairs | ||||||||
| 10P x 1.0 | 7 / 0.43 | 0.6 | 22.5 | 626 | 22.5 | 1.60 | 29.3 | 1800 |
| 10P x 1.5 | 7 / 0.53 | 0.7 | 28.0 | 811 | 28.0 | 1.60 | 35.0 | 2165 |
| 10P x 2.5 | 7 / 0.67 | 0.8 | 31.5 | 1132 | 31.5 | 2.00 | 39.5 | 3007 |
| 20 Pairs | ||||||||
| 20P x 1.0 | 7 / 0.43 | 0.6 | 30.5 | 1143 | 30.5 | 2.00 | 38.5 | 3019 |
| 20P x 1.5 | 7 / 0.53 | 0.7 | 38.0 | 1509 | 38.0 | 2.00 | 46.2 | 3684 |
| 20P x 2.5 | 7 / 0.67 | 0.8 | 42.5 | 2112 | 42.5 | 2.50 | 51.9 | 5107 |
(Note: Other conductor sizes & core configurations are available upon request.)
Factory Overview
Packaging & Shipping


Frequently Asked Questions (FAQ)
Q1: What does the “I” in FR-XlOL stand for, and how does it differ from standard FR-XOL?
A: The “I” stands for Individual screen. Unlike the FR-XOL (which only has an overall screen), the FR-XlOL features an aluminium/polyester screen over each individual pair, plus an overall screen. This dual screening provides maximum protection against both internal crosstalk and external electromagnetic interference (EMI).
Q2: What is the primary application for double-screened instrumentation cables?
A: They are ideal for highly sensitive control and measurement systems, such as those found in petrochemical plants, power stations, and complex fire alarm networks, where transmitting accurate signals without interference is absolutely critical.
Q3: What is the difference between FR-XlOL and FR-XlOSL?
A:
-
FR-XlOL: The unarmoured version, offering flexibility for standard routing.
-
FR-XlOSL: Includes a Galvanized Steel Wire Armour. The ‘S’ in the designation indicates this extra layer of mechanical protection against impact, crushing, and rodent damage, suitable for harsh environments or direct burial.
Q4: How does the Mica Tape ensure the cable works during a fire?
A: The Mica Tape is wrapped directly over the copper conductors. Under intense heat, the mica compound turns into a hard, ceramic-like insulating crust. This prevents the conductors from short-circuiting, allowing emergency power and signals to continue flowing.
Q5: What do the reference standards BS 5308 and BS 7629 guarantee?
A:
-
BS 5308: Ensures the cable meets the strict electrical and physical requirements for instrumentation cables.
-
BS 7629: Certifies that the cable can maintain circuit integrity and continue to function during a fire, making it suitable for life safety systems.
Q6: Why is the outer sheath colored Orange?
A: The Orange sheath is a universally recognized safety color used to quickly identify Fire Resistant cables, ensuring they are easily distinguished from standard power or data cables during installation and maintenance.


Reviews