Security / Audio Cable (Figure 8) – 30V Flexible Twin-Core PVC Cable (AS/NZS Standards)

The Figure 8 security and audio cable provides dependable electrical connections for sound transmission, broadcasting and low-voltage audio applications. It features plain annealed copper conductors stranded according to IEC 60228 Class 5 and a V-90HT PVC sheath.

Furthermore, its parallel twin-core Figure 8 construction supports flexibility, easy conductor separation and convenient installation. With a rated voltage of 30V and a manufacturer-specified maximum operating temperature of 105°C, this flexible audio cable is available in conductor cross-sections ranging from 0.5 mm² to 2.6 mm². It provides a practical solution for sound systems, broadcasting equipment and compatible low-voltage audio installations.

Application

Security and audio cables with Figure 8 construction provide reliable electrical connections for sound transmission, broadcasting and audio signal applications. Their parallel twin-core design makes them suitable for speaker connections, sound systems and low-voltage audio equipment.

Furthermore, the IEC 60228 Class 5 stranded plain annealed copper conductors provide excellent flexibility and efficient electrical conductivity. The V-90HT PVC sheath provides insulation and protection for low-voltage signal transmission applications.

In addition, the Figure 8 construction allows the two conductors to be separated easily during termination, simplifying installation and electrical connections.

Cable Construction

  • Standards: AS/NZS 5000, AS/NZS 1125, IEC 60228, IEC 60332-1, AS/NZS 3808.

  • Rated Voltage: 30V.

  • Conductor: Plain annealed copper stranded according to IEC 60228 Class 5.

  • Sheath: V-90HT PVC (Polyvinyl Chloride).

  • Maximum Operating Temperature: 105°C, as specified in the datasheet.

  • Sheath Marking: Manufacturer’s name (trademark) and type, production year/week or batch number, and metre markings.

  • Special Properties: Flexible conductor construction and parallel Figure 8 design.

  • Cable Type: Twin-core security and audio cable.

  • Available Cross-Sections: 0.5 mm², 0.75 mm², 1.0 mm², 2.0 mm² and 2.6 mm².

Technical Data

The security / audio cable (Figure 8) features a rated voltage of 30V and a manufacturer-specified maximum operating temperature of 105°C. Its V-90HT PVC sheath provides insulation and protection for low-voltage audio and signal transmission applications.

Moreover, the IEC 60228 Class 5 stranded copper conductors support flexibility and ease of installation. The listed conductor cross-sections range from 0.5 mm² to 2.6 mm².

The sheath thickness ranges from 0.5 mm to 1.0 mm, while the overall cable dimensions range from 4.3 × 1.8 mm to 9.0 × 4.5 mm. The approximate cable weight ranges from 20 kg/km to 81 kg/km.

Furthermore, the maximum DC conductor resistance at 20°C ranges from 7.4 Ω/km to 44.5 Ω/km, while the maximum voltage drop ranges from 16.3 mV/A/m to 97.8 mV/A/m.

Constructive Data Table

Cross-section (mm²) Conductor No. of Strands Sheath Thickness (mm) Overall Dimensions (mm) Max. DC Resistance at 20°C (Ω/km) Max. Voltage Drop (mV/A/m) Approx. Weight (kg/km)
0.5 14/0.20 0.5 4.3 × 1.8 44.5 97.8 20
0.75 24/0.20 0.80 5.9 × 2.9 26.00 57.10 30.00
1.0 91/0.12 0.5 5.7 × 2.6 17.2 37.8 34
2.0 64/0.20 0.8 7.0 × 3.4 10.9 23.9 52
2.6 84/0.20 1.0 9.0 × 4.5 7.4 16.3 81

Technical note: All numerical table values and measurement units remain unchanged from the original datasheet. However, the specified maximum operating temperature of 105°C should be verified against the V-90HT PVC material designation and applicable operating conditions. The manufacturer also lists AS/NZS 5000 without specifying the applicable part or edition. Please confirm these details before publishing.

Factory Overview


Packaging & Shipping


Frequently Asked Questions and Answers

Q:- What is the primary application of the security / audio cable (Figure 8)?

A:- It is designed for sound transmission, broadcasting, audio signal transmission and suitable low-voltage audio equipment connections.

Q:- What standards does the Figure 8 security and audio cable follow?

A:- The manufacturer lists AS/NZS 5000, AS/NZS 1125, IEC 60228, IEC 60332-1 and AS/NZS 3808 in the product datasheet.

Q:- What is the rated voltage of the Figure 8 audio cable?

A:- The rated voltage is 30V, making it suitable for low-voltage applications within its specified electrical rating.

Q:- What is the maximum operating temperature of the security / audio cable?

A:- The manufacturer specifies a maximum operating temperature of 105°C. However, the applicable operating conditions should be confirmed with the manufacturer.

Q:- What type of conductor does the Figure 8 audio cable use?

A:- It uses plain annealed copper conductors stranded according to IEC 60228 Class 5, providing flexibility and efficient electrical conductivity.

Q:- What type of sheath does the security / audio cable feature?

A:- It features V-90HT PVC (Polyvinyl Chloride) sheathing.

Q:- What is the advantage of Figure 8 cable construction?

A:- The Figure 8 design features two parallel conductors joined together, allowing easy separation during termination and simplifying cable routing and installation.

Q:- What conductor cross-section sizes are available?

A:- The listed conductor cross-section sizes are 0.5 mm², 0.75 mm², 1.0 mm², 2.0 mm² and 2.6 mm².

Q:- Is the Figure 8 security and audio cable flame-retardant?

A:- The manufacturer lists IEC 60332-1, which relates to vertical flame propagation testing of a single insulated wire or cable. Specific test compliance should be confirmed with the manufacturer.

Q:- Can the Figure 8 audio cable be used for mains power connections?

A:- No, this cable has a rated voltage of 30V and is intended for low-voltage applications. It must not be used for standard mains power connections.

Reviews

There are no reviews yet.

Be the first to review “Security / Audio Cable (Figure 8) – 30V Flexible Twin-Core PVC Cable (AS/NZS Standards)”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS