TPP Local Network Communication Cable (x2x0.4 to x2x0.7)

This local network communication cable is engineered for PABX systems and signal transmission in both underground and interior installations. It features a bare copper conductor with PE insulation and a laminated aluminium tape screen with a copper wire for excellent interference protection. The PE low-density outer sheath ensures durability for demanding network infrastructure. Available in various configurations, it is suitable for fire and explosion hazard locations with proper safety precautions.

These communication cables are primarily used as connecting cables in local networks and PABX systems for telephone purposes and for the transmission of signals. Because they are suitable for underground installations, cable ducts, and conduits, they are highly versatile for both exterior and interior applications. Furthermore, they are suitable for interior installations, provided that the cables are only used in locations with fire and explosion hazards in accordance with the appropriate safety precautions. Consequently, this makes them reliable for structured cabling and network infrastructure projects.

The cable structure features a bare copper conductor with diameters of 0.4 mm, 0.5 mm, 0.6 mm, or 0.7 mm, which is insulated with PE low density. Four wires are twisted into a quad, and 5 quads are twisted in a basic unit. The cable core wrapping consists of several layers of plastic tapes. For screening, an aluminum tape with a thickness of no less than 0.06mm is applied, one side coated with copolymer, followed by a laminated copper wire with a diameter of 0.5mm. Finally, the outer sheath is made of PE low density with 2.5% carbon black.

Technical Data & Construction Overview:

  • Conductor diameter: 0.4 mm / 0.5 mm / 0.6 mm / 0.7 mm

  • Conductor resistance at 20°C-max: 150 Ω/km / 95 Ω/km / 65 Ω/km / 48 Ω/km

  • Insulation resistance – min: 10 GΩ x km

  • Mutual capacitance at 800Hz-nom: 48 nF/km

  • Capacitance unbalances at 800Hz-max: K1: 980 pF/500m; Ke: 1,500 pF/500m; K9-K12: 50% of all values; K9-K12: 300 pF/500m; 20% of all values; 200 pF/500m

  • Test voltage 50Hz, 2 min: 500V / 2000V

  • Operating voltage peak value: 150V / 220V

  • Temperature range: Laying and installing -10°C up to +60°C; Exploitation and storage -40°C up to +60°C

  • Bending radius, min. approx.: 10 x cable diameter

Cable core construction

Number of pairs Number of quads Number of units in the layers
1-st layer 5×4 2-nd layer 25×4 1-st layer 50×4
6 3 3-quads
10 5 5
20 10 5 5
30 15 5 10
50 25 5 7 5
100 50 3 6
150 75 3
200 100 4 4
250 125 5 5
300 150 6
400 200 8
500 250 5 5
600 300 6 6
700 350 7 7
800 400 8 8
1000 500 10

Construction data TPP…x2x0.4

Number of pairs Outer diameter approx. mm Copper weight approx. kg/km Cable weight approx. kg/km
2 7.4 17 51
4 8.1 17 57
6 9.9 17 91
10 10.7 25 117
20 15.3 51 249
30 17.5 76 324
50 20.2 127 484
100 24.7 254 810
150 30.4 376 1186
200 33.7 381 1402
300 38.7 635 1936
400 46.6 851 2733
500 47.8 1276 2322
600 50.4 1276 2813
700 56.0 1966 3527
800 58.0 1966 3924
1000 65.0 2548 4936
1200 65.0 3056 5447

Construction data TPP…x2x0.5

Number of pairs Outer diameter approx. mm Copper weight approx. kg/km Cable weight approx. kg/km
2 8.1 13 44
4 9.0 21 58
6 9.8 25 74
10 11.3 39 114
20 15.2 76 197
30 18.1 111 281
50 22.5 203 463
100 32.9 387 833
150 37.9 634 1197
200 40.5 831 1600
300 49.0 1276 1980
400 51.7 1503 2500
500 60.5 2000 3400
600 64.2 2400 3967
700 68.2 2800 4593
800 76.3 3200 5240
1000 76.3 3240 7387

Construction data TPP…x2x0.6

Number of pairs Outer diameter approx. mm Copper weight approx. kg/km Cable weight approx. kg/km
2 8.3 15 46
4 9.6 25 71
6 10.0 38 90
10 12.1 58 127
20 17.2 113 247
30 19.9 170 332
50 25.6 269 518
100 35.7 531 880
150 38.1 833 1312
200 48.8 1133 1810
300 54.1 1685 2785
400 59.3 2086 3231
500 67.7 2500 4000
600 72.1 3200 4807
700 76.3 3796 5596

Construction data TPP…x2x0.7

Number of pairs Outer diameter approx. mm Copper weight approx. kg/km Cable weight approx. kg/km
2 10.1 19 107
4 11.9 34 152
6 12.7 48 182
10 15.0 74 227
20 22.0 113 461
30 25.6 165 616
50 31.1 263 1023
100 44.1 525 1835
150 51.7 786 2460
200 57.1 1119 3048
300 68.0 1731 4640
400 69.3 2530 5440
500 76.3 3240 7387

Factory Overview



Packaging & Shipping


Frequently asked questions and answer (Q:- A:-)

Q:- What is the primary application of the TPP cable?
A:- It is used as connecting cables in local networks and PABX systems for telephone and signal transmission.
Q:- Can this cable be installed underground?
A:- Yes, it is suitable for underground installations, cable ducts, and conduits.
Q:- What conductor diameters are available for this cable?
A:- The cable is available with conductor diameters of 0.4 mm, 0.5 mm, 0.6 mm, and 0.7 mm.
Q:- What is the maximum conductor resistance for the 0.4 mm version?
A:- The maximum conductor resistance is 150 Ω/km.
Q:- How is the cable protected against electromagnetic interference?
A:- It features an aluminium tape screen with a laminated copper wire.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is approximately 10 times the cable diameter.
Q:- What is the temperature range for laying and installing?
A:- The laying and installing temperature range is -10°C up to +60°C.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PE low density with 2.5% carbon black.
Q:- How is the color coding structured?
A:- Each unit has a red supporting spiral for counting start and a yellow supporting spiral for counting direction.
Q:- What is the nominal mutual capacitance at 800 Hz?
A:- The nominal mutual capacitance is 48 nF/km.

Reviews

There are no reviews yet.

Be the first to review “TPP Local Network Communication Cable (x2x0.4 to x2x0.7)”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS