MKBP … x4x1.2 High-Frequency Trunk Cable – BDS 5052-90

The MKBP … x4x1.2 cable delivers dependable signal transmission for trunk cable communication networks and telephone exchanges. Constructed with bare copper conductors, paper string insulation, a lead-containing sheath, steel tape armours, and a protective PE sheath, it offers high protection against interference and mechanical damage for signals up to 552 kHz. Because it meets BDS 5052-90 standards, it provides a reliable solution for long-distance connections in ditches and inclined terrains.

Application
MKBP cables provide reliable signal transmission for the construction of trunk cable communication networks and connection lines between automatic telephone exchanges. Because they feature paper band insulation and robust protective sheaths, installers use them for multi-channel systems with a frequency range up to 552 kHz. Furthermore, they are suitable for laying in ditches where there is less force of strain and inclined terrain less than 45°. However, using these cables for high voltage power installations is not permitted.

Cable construction
This cable strictly adheres to BDS 5052-90 standards. It features a bare copper conductor with a diameter of 1.2 mm. The insulation uses paper string insulation, with four wires twisted into a quad. The quads are twisted concentrically into layers, wrapped with several layers of paper tapes. A lead-containing sheath (with an antimony of 0.4 to 0.6%) forms the pad, followed by bitumen and impregnated cable paper. The armour consists of two steel tape amours, and a protective PE sheath with low density with 2.5% carbon black completes the assembly. This product is designed for high-frequency communication networks.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a resistance of side circuit at 31.7 Ω/km and a conductor diameter of 1.2 mm. The ohmic asymmetry is max. 0.1 Ω/425m, and the insulation resistance is min. 12,000 MΩ.km. The mutual capacitance at 800 Hz is 26.5 nF/km. Attenuation near the end between all side-circuits at 552 kHz is 6.26 dB/425 (90% of all combinations) and 5.67 dB/425 (100% of all combinations). Protection of far end between all side-circuits at 552 kHz is 70.0 dB/425 (90% of all combinations) and 65.0 dB/425 (100% of all combinations). Test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath). The operating voltage peak value is 300 V. The temperature range is -5 °C to +50 °C (laying and installing) and -40 °C to +70 °C (exploitation and storage). The minimum bending radius is 20 times the cable diameter.

Color coding & Core Construction
The color coding features side circuit 1 (a-wire: blue, b-wire: white) and side circuit 2 (a-wire: red, b-wire: green). In each layer, there is a quad with a supporting spiral and an inscription of the counting direction “yellow” in the supporting spiral. The quads are arranged in layers: 3 quads (all in first layer), 4 quads (1 in centre, 3 in first layer), 7 quads (1 in centre, 6 in first layer).

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data MKBP …x4x1.2

Number of quads Outer diameter approx. Copper weight Cable weight approx.
mm kg/km kg/km
3 27,7 154 1624
4 28,3 205 1858
7 34,0 313 2584

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the MKBP cable?
A:- It is used for the construction of trunk cable communication networks and connection lines between automatic telephone exchanges, transmitting signals up to 552 kHz.

Q:- What are the key mechanical protection features of this cable?
A:- It features two steel tape armours and a protective PE sheath with low density and 2.5% carbon black, providing robust protection for installation in ditches.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 5052-90 standards.

Q:- What type of conductor and insulation does it use?
A:- It uses a bare copper conductor with a diameter of 1.2 mm and paper string insulation.

Q:- What is the temperature range for this cable?
A:- The temperature range is -5°C to +50°C for laying and installing, and -40°C to +70°C for exploitation and storage.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is 26.5 nF/km.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 20 times the cable diameter (20 x D cable).

Q:- What is the operating voltage peak value?
A:- The operating voltage peak value is 300 V.

Q:- Is this cable permitted for high voltage power installations?
A:- No, the use of these cables for high voltage power installations is not permitted.