LiYCY-fr Flexible Flame Retardant Paired Screened Cable – VDE 0812
The LiYCY-fr cable delivers dependable signal and data transmission for telecommunication systems and industrial electronics. Constructed with flexible plain copper conductors, PVC insulation, twisted pairs, a tinned copper wire braid screen, and a grey flame retardant PVC outer sheath, it offers exceptional flexibility and interference protection. Because it meets VDE 0812 standards, passes the BDS IEC 332-3 Category C test, and is CE/RoHS compliant, it provides a safe and reliable solution for installations in dry and moist rooms.
Application
LiYCY-fr cables provide reliable voice and data transmission for telecommunication systems, pulse applications, and signal transmission. Because the twisted pairs with optimum pair and layer pitch prevent mutual interaction between neighboring conductors, installers use them for precise signal integrity. Furthermore, the overall braided screen of tinned copper wire provides approximately 85% coverage protection against external pulses. Additionally, these cables are suitable for flexible and permanent installation in dry and moist rooms, particularly when non-propagation of flames is required.
Cable construction
This cable strictly adheres to VDE 0812 standards. It features flexible plain Cu wires with varied constructions (e.g., 0.25mm² = 14×0.15mm). The insulation uses a PVC compound type YI2 according to VDE 0207 part 4. Core identification uses colors according to DIN 47 100, with each wire twisted to a pair. The pairs are stranded into layers with plastic foil overlapping. A wrapping screen of tinned copper wire braid provides 85% coverage. Finally, a grey (RAL 7032) PVC compound flame retardant and reduced corrosive gas emission sheath protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C ranging from 80 Ω/km (0.25 mm²) to 13.3 Ω/km (1.5 mm²). The mutual capacitance at 800 Hz is max. 150 pF/m. The capacitance unbalance at 800 Hz (K1 max) is max. 300 pF/100m. The insulation resistance is min. 200 MΩ.km. The test voltage is 50 Hz, 1 min, 1200V. The operating voltage peak is 500V. The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +70 °C. The minimum bending radius is 15 x cable diameter. Furthermore, it passes the flame retardancy test according to BDS IEC 332-3, Category C.
Color coding
Clear color coding ensures safe and accurate wiring. The b-wire pair colors are: 1-brown, 2-yellow, 3-pink, 4-red, 5-violet. The a-wire pair colors are: 1-white, 2-green, 3-grey, 4-blue, 5-black.
Type codes
Li = stranded wire conductor, Y = insulation of PVC, C = screen of copper wire braid, Y-fr = sheath of PVC, flame retardant.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data LiYCY-fr…
| Number of pairs | External diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|
| 2×0,25 mm² | mm | kg/km | kg/km |
| 1 | 4,1 | 15 | 26 |
| 2 | 6,0 | 29 | 49 |
| 3 | 6,3 | 38 | 60 |
| 4 | 6,9 | 44 | 72 |
| 5 | 7,5 | 55 | 85 |
| 2×0,5 mm² | |||
| 1 | 4,7 | 20 | 40 |
| 2 | 7,1 | 40 | 80 |
| 3 | 7,5 | 48 | 100 |
| 4 | 9,3 | 80 | 133 |
| 5 | 10,2 | 93 | 155 |
| 2×0,75 mm² | |||
| 1 | 5,1 | 35 | 55 |
| 2 | 8,8 | 62 | 115 |
| 3 | 9,3 | 75 | 138 |
| 4 | 10,1 | 95 | 165 |
| 5 | 11,1 | 115 | 195 |
| 2×1,0 mm² | |||
| 1 | 5,4 | 38 | 58 |
| 2 | 9,4 | 72 | 130 |
| 3 | 9,8 | 85 | 160 |
| 4 | 10,8 | 117 | 198 |
| 5 | 11,9 | 140 | 230 |
| 2×1,5 mm² | |||
| 1 | 6,4 | 52 | 79 |
| 2 | 11,0 | 98 | 170 |
| 3 | 11,6 | 120 | 205 |
| 4 | 12,8 | 160 | 265 |
| 5 | 14,1 | 195 | 310 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the LiYCY-fr cable?
A:- It is used for voice communication, pulse, and signal data transmission in telecommunication systems and industrial electronics, especially where non-propagation of flames is required.
Q:- What are the key features of the screen and twisted pairs?
A:- The twisted pairs prevent mutual interaction between neighboring conductors, while the tinned copper wire braid screen provides approximately 85% protection against external pulses.
Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0812 standards, and the conductor complies with VDE 0295 / IEC 60228 class 5.
Q:- What type of conductor and insulation does it use?
A:- It uses flexible plain copper wires with a PVC compound type YI2 insulation.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +50°C.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 150 pF/m.
Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min, 1200V.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.
Q:- What is the operating voltage peak?
A:- The operating voltage peak is 500V.
Q:- What do the type codes Li, Y, C, and Y-fr stand for?
A:- Li indicates a stranded wire conductor, Y indicates PVC insulation, C indicates a copper wire braid screen, and Y-fr indicates a flame retardant PVC sheath.