TPPBP Local Network Communication Cable with Armour (x2x0.4 to x2x0.7)
This armoured local network communication cable is engineered for PABX systems and signal transmission in all types of grounds. It features a bare copper conductor with PE insulation and a laminated aluminium tape screen with a tinned copper wire for excellent interference protection. Two steel tapes provide robust mechanical protection, while the PE low-density outer sheath ensures durability against environmental factors. Available in various configurations, it is strictly designed for signal transmission and not for power installations.
These communication cables are specifically used as connecting cables in local networks and PABX systems for telephone purposes and for the transmission of signals. Because they are suitable for laying in all types of grounds, they are exceptionally durable for outdoor and underground infrastructure projects. However, it should be noted that the use of these cables for power installations is explicitly not permitted, ensuring they remain dedicated to signal transmission applications.
The cable structure features a bare copper conductor with diameters of 0.4 mm, 0.5 mm, 0.6 mm, or 0.7 mm, which is insulated with PE low density. Four wires are twisted into a quad, and 5 quads are twisted to a basic unit. The units are stranded into a cable with a laminated aluminium tape screen, which has a thickness of no less than 0.06mm, one side coated with copolymer, and a tinned copper wire with a diameter of 0.5mm under the aluminium foil. For mechanical protection, two steel tapes with a thickness of 0.3mm are applied. Finally, the assembly is protected by a PE low density protective sheath containing 2.5% carbon black.
Technical Data & Construction Overview:
-
Conductor diameter: 0.4 mm / 0.5 mm / 0.6 mm / 0.7 mm
-
Conductor resistance at 20°C-max: 150 Ω/km / 95 Ω/km / 65 Ω/km / 48 Ω/km
-
Insulation resistance – min: 10 GΩ x km
-
Mutual capacitance at 800Hz-nom: 48 nF/km
-
Capacitance unbalances at 800Hz-max: K1: 980 pF/500m; Ke: 1,500 pF/500m; K9-K12: 50% of all values; K9-K12: 300 pF/500m; 20% of all values; 200 pF/500m
-
Test voltage 50Hz, 2 min: Wire-wire 500V / Wire-screen 2000V
-
Operating voltage peak value: Cables with cores 0.4 and 0.5mm: 150V; Cables with cores 0.6 and 0.7mm: 220V
-
Temperature range: Laying and installing -10°C up to +60°C; Exploitation and storage -40°C up to +60°C
-
Bending radius, min. approx.: 10 x cable diameter
Cable core construction
| Number of pairs | Number of quads | Number of units in the layers | |||||
|---|---|---|---|---|---|---|---|
| 1-st layer | 5×4 | 2-nd layer | 25×4 | 1-st layer | 50×4 | ||
| 3 | 3-quads | ||||||
| 6 | 3 | 3-quads | |||||
| 10 | 5 | 5 | |||||
| 20 | 10 | 5 | 5 | ||||
| 30 | 15 | 5 | 10 | ||||
| 50 | 25 | 5 | 7 | ||||
| 75 | 1 | 6 | 3 | ||||
| 100 | 50 | 3 | 4 | ||||
| 125 | 5 | ||||||
| 150 | 75 | 1 | 5 | ||||
| 200 | 4 | ||||||
| 250 | 5 | ||||||
| 300 | 1 | 5 | |||||
| 400 | 1 | 6 | |||||
| 500 | 2 | 7 | |||||
| 600 | 4 | 8 |
Construction data TPPBP…x2x0.4
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 6 | 11.2 | 17 | 176 |
| 10 | 13.0 | 27 | 229 |
| 20 | 15.5 | 50 | 292 |
| 30 | 16.5 | 74 | 329 |
| 50 | 21.8 | 124 | 604 |
| 100 | 26.6 | 250 | 1047 |
| 150 | 31.1 | 374 | 1361 |
| 200 | 33.1 | 494 | 1633 |
| 250 | 35.5 | 633 | 1937 |
| 300 | 38.1 | 752 | 2108 |
| 400 | 42.7 | 983 | 2482 |
| 500 | 48.0 | 1275 | 3017 |
| 600 | 50.4 | 1475 | 3444 |
| 700 | 57.0 | 1722 | 4019 |
| 800 | 63.0 | 1969 | 4808 |
| 1000 | 63.2 | 2454 | 4735 |
| 1200 | 68.3 | 2941 | 5563 |
Construction data TPPBP…x2x0.5
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 6 | 12.6 | 26 | 221 |
| 10 | 15.8 | 42 | 287 |
| 20 | 15.6 | 78 | 345 |
| 30 | 20.8 | 118 | 429 |
| 50 | 22.6 | 195 | 535 |
| 70 | 29.9 | 269 | 784 |
| 100 | 30.1 | 384 | 1094 |
| 150 | 35.1 | 630 | 1394 |
| 200 | 35.5 | 786 | 1584 |
| 250 | 42.0 | 1176 | 2222 |
| 300 | 45.5 | 1500 | 2450 |
| 400 | 46.4 | 1755 | 2829 |
| 500 | 51.4 | 1918 | 3317 |
| 600 | 53.0 | 2756 | 4010 |
| 700 | 58.0 | 3070 | 4533 |
| 800 | 62.0 | 3676 | 5202 |
| 1000 | 67.2 | 4010 | 5989 |
| 1200 | 75.3 | 5210 | 7358 |
Construction data TPPBP…x2x0.6
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 6 | 14.1 | 36 | 241 |
| 10 | 15.0 | 57 | 277 |
| 20 | 17.5 | 101 | 369 |
| 30 | 19.3 | 164 | 545 |
| 50 | 23.5 | 263 | 784 |
| 70 | 27.2 | 387 | 985 |
| 100 | 30.7 | 536 | 1288 |
| 150 | 36.7 | 851 | 1830 |
| 200 | 41.5 | 1102 | 2238 |
| 250 | 44.0 | 1517 | 2732 |
| 300 | 46.4 | 1950 | 3209 |
| 400 | 56.4 | 2366 | 4099 |
| 500 | 54.6 | 3079 | 5247 |
| 600 | 66.1 | 3650 | 6408 |
| 700 | 67.5 | 4469 | 7586 |
| 800 | 71.8 | 4861 | 7569 |
Construction data TPPBP…x2x0.7
| Number of pairs | Outer diameter approx. mm | Copper weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|
| 4 | 14.1 | 46 | 277 |
| 6 | 16.0 | 60 | 322 |
| 10 | 16.0 | 75 | 464 |
| 20 | 20.4 | 146 | 645 |
| 30 | 27.4 | 201 | 981 |
| 50 | 28.0 | 331 | 1190 |
| 100 | 36.3 | 703 | 1865 |
| 150 | 43.7 | 1043 | 2593 |
| 200 | 43.2 | 1482 | 3289 |
| 250 | 44.3 | 1969 | 4179 |
| 300 | 50.3 | 2300 | 4561 |
| 400 | 54.2 | 2803 | 5587 |
| 500 | 59.6 | 3521 | 7164 |
| 600 | 65.0 | 4232 | 8032 |
| 700 | 73.2 | 4999 | 9351 |
| 800 | 76.5 | 5658 | 11488 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of the TPPBP cable?
A:- It is used as connecting cables in local networks and PABX systems for telephone and signal transmission.
Q:- Where is this cable suitable for installation?
A:- It is suitable for laying in all types of grounds, including outdoor and underground environments.
Q:- Can this cable be used for power installations?
A:- No, the use of these cables for power installations is explicitly not permitted.
Q:- What conductor diameters are available for this cable?
A:- The cable is available with conductor diameters of 0.4 mm, 0.5 mm, 0.6 mm, and 0.7 mm.
Q:- How is the cable protected against mechanical damage?
A:- It is protected by two steel tapes with a thickness of 0.3mm.
Q:- How is the cable protected against electromagnetic interference?
A:- It features a laminated aluminium tape screen with a tinned copper wire.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is approximately 10 times the cable diameter.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PE low density with 2.5% carbon black.
Q:- What is the temperature range for laying and installing?
A:- The laying and installing temperature range is -10°C up to +60°C.
Q:- What is the nominal mutual capacitance at 800 Hz?
A:- The nominal mutual capacitance is 48 nF/km.