SVBVn/A 0.6/1 kV Flame Retardant Armoured Power Cable – FN KI 02.001-96
The SVBVn/A 0.6/1 kV cable delivers dependable power distribution for industrial and commercial installations. Constructed with copper conductors, PVC insulation, a flame retardant filling, steel tape armour, and a black flame retardant PVC outer sheath, it offers exceptional fire safety and mechanical protection. Because it meets FN KI 02.001-96 standards, passes the BDS IEC 332-3/C2 Category A flame test, and is RoHS compliant, it provides a safe and reliable solution for electrical networks requiring non-proliferation of flames.
Application
SVBVn/A cables provide reliable power transfer and distribution in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they feature steel tape armour and flame retardant materials, installers use them for the fixed installation and construction of electrical networks and installations. Furthermore, they ensure safety in environments requiring non-proliferation of flames. Additionally, the robust armour protects the cable from mechanical damage, making it suitable for harsh conditions. Consequently, they deliver consistent performance and safety in demanding industrial environments.
Cable construction
This cable strictly adheres to FN KI 02.001-96 standards. It features copper solid or twisted wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound according to BDS 5792-84. A filling with flame retardant properties forms the inner sheath. The armour consists of steel tapes. Finally, a black PVC flame retardant outer sheath of flame retardancy category A protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to BDS 904-84. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 4 kV (alternating) and 12 kV (direct). The temperature range for laying and installing is -5 °C, while the exploitation and storage range is -30 °C to +50 °C. The operating temperature reaches +70 °C. The short circuit temperature is +160 °C for no more than 5 seconds. Installers must respect a minimum bending radius of 10 times the cable diameter. Furthermore, it passes the flame retardant test according to BDS IEC 332-3/C2, Category A.
Color coding
Clear color coding ensures safe and accurate wiring. Conductors without a yellow/green earth core feature random colors for 1 core, brown and blue for 2 cores, brown, black, and blue for 3 cores, and blue, brown, black, and grey for 4 cores. Conductors with a yellow/green earth core feature yellow/green, blue, and brown for 3 cores, and yellow/green, brown, black, and grey for 4 cores. The neutral conductor is always blue.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data SVBVn/A 0.6/1 kV
| Number of cond. and nominal cross section | Form of conductor | Cable diameter approx. | Mass of Cu | Mass of cable approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 2 x 1,5 | re | 12,8 | 28 | 315 |
| 2 x 2,5 | re | 13,0 | 46 | 360 |
| 2 x 4,0 | re | 15,2 | 73 | 478 |
| 2 x 6,0 | re | 17,2 | 110 | 584 |
| 2 x 10 | re | 18,8 | 182 | 680 |
| 2 x 16 | re | 20,6 | 303 | 862 |
| 2 x 25 | rm | 25,1 | 470 | 1298 |
| 2 x 35 | rm | 27,4 | 652 | 1518 |
| 2 x 50 | rm | 31,0 | 928 | 2016 |
| 3 x 1,5 | re | 13,7 | 42 | 350 |
| 3 x 2,5 | re | 14,5 | 69 | 410 |
| 3 x 4,0 | re | 16,7 | 110 | 529 |
| 3 x 6,0 | re | 18,0 | 165 | 631 |
| 3 x 10 | re | 20,0 | 275 | 800 |
| 3 x 16 | re | 22,0 | 450 | 1022 |
| 3 x 25 | rm | 26,5 | 700 | 1555 |
| 3 x 35 | rm | 28,2 | 980 | 2023 |
| 3 x 50 | rm | 32,8 | 1390 | 2948 |
| 3 x 70 | sm | 33,0 | 1950 | 2940 |
| 3 x 95 | sm | 38,0 | 2650 | 3386 |
| 3 x 120 | sm | 40,0 | 3350 | 4016 |
| 3 x 150 | sm | 44,2 | 4185 | 5841 |
| 3 x 185 | sm | 47,9 | 5160 | 7125 |
| 3 x 240 | sm | 53,3 | 6720 | 8200 |
| 3 x 300 | sm | 58,7 | 8205 | 11198 |
| 3 x 2,5+1,5 | re/re | 16,2 | 82 | 461 |
| 3 x 4,0+2,5 | re/re | 17,8 | 132 | 546 |
| 3 x 6,0+4,0 | re/re | 18,8 | 202 | 639 |
| 3 x 10+6,0 | re/re | 21,1 | 330 | 922 |
| 3 x 16+10 | rm/re | 23,2 | 549 | 1223 |
| 3 x 25+16 | rm/re | 27,6 | 850 | 1616 |
| 3 x 35+16 | rm/rm | 30,1 | 1131 | 1812 |
| 3 x 50+25 | sm/rm | 34,1 | 1680 | 2698 |
| 3 x 70+35 | sm/rm | 34,2 | 2280 | 2978 |
| 3 x 95+50 | sm/rm | 38,2 | 3120 | 3548 |
| 3 x 120+70 | sm/rm | 42,4 | 4010 | 4980 |
| 3 x 150+70 | sm/rm | 45,6 | 4850 | 5596 |
| 3 x 185+95 | sm/rm | 50,2 | 6070 | 6933 |
| 3 x 240+120 | sm/rm | 54,4 | 7840 | 8356 |
| 3 x 300+150 | sm/rm | 60,9 | 9928 | 10800 |
| 4 x 1,5 | re | 14,5 | 55 | 390 |
| 4 x 2,5 | re | 14,7 | 92 | 444 |
| 4 x 4,0 | re | 18,3 | 146 | 621 |
| 4 x 6,0 | re | 19,5 | 218 | 734 |
| 4 x 10 | re | 21,5 | 363 | 975 |
| 4 x 16 | re | 23,7 | 595 | 1275 |
| 4 x 25 | rm | 29,0 | 925 | 1938 |
| 4 x 35 | rm | 31,8 | 1303 | 2400 |
| 4 x 50 | sm | 33,7 | 1857 | 3335 |
| 4 x 70 | sm | 38,2 | 2601 | 3848 |
| 4 x 95 | sm | 42,4 | 4460 | 5256 |
| 4 x 120 | sm | 45,6 | 5575 | 6250 |
| 4 x 150 | sm | 50,2 | 5855 | 7740 |
| 4 x 185 | sm | 54,5 | 6790 | 9100 |
| 4 x 240 | sm | 61,0 | 8928 | 11928 |
| 4 x 300 | sm | 66,7 | 11050 | 14655 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SVBVn/A cable?
A:- It is used for fixed installation and construction of electrical networks and installations, intended for power transfer and distribution in areas requiring non-proliferation of flames and mechanical protection.
Q:- What are the key mechanical protection features of this cable?
A:- It features an armour made of steel tapes, providing robust protection against mechanical damage.
Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.001-96 standards, and the conductor complies with BDS 904-84 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses copper solid or twisted wires (class 1 or 2) with a PVC compound insulation according to BDS 5792-84.
Q:- What is the temperature range for this cable?
A:- The temperature range for laying and installing is -5°C, while the exploitation and storage range is -30°C to +50°C.
Q:- What is the maximum operating and short-circuit temperature?
A:- The operating temperature is +70°C, and the short-circuit temperature is +160°C for no more than 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV (alternating) and 12 kV (direct).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).
Q:- What is the neutral conductor color?
A:- The neutral conductor is always blue.
Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.