NYY 0.6/1 kV Low voltage Control Cable – Solid & Stranded Copper for Industrial Use

The NYY 0.6/1 kV cable is a heavy-duty solution for industrial power distribution. It features solid or multi-strand copper conductors, PVC insulation, and a robust black PVC outer sheath. Designed to perform in demanding environments, it is ideal for power plants, underground networks, and outdoor installations where mechanical damage is not expected.

Application
NYY cables provide reliable power distribution in power plants, industrial settings, and switching installations. They also excel in secondary distribution networks. Because of their robust design, they are preferred for outdoor applications, indoor installations, open air, underground, and even in water. However, you should not use them where mechanical damage is anticipated.

Cable Construction
This cable strictly adheres to VDE 0276 part 627 standards. It features solid or multi-strand copper wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses PVC type DIV4 according to VDE0207, while core identification follows VDE 0293. Additionally, a filling compound or tapes form the inner sheath. Finally, a black PVC type DMV5 sheath (acc. VDE 0207) protects the entire assembly.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for multi-core cables, or 12 times for single-core cables. Furthermore, it passes the flame test according to VDE 0472 part 804 class B (IEC 332 part 1).

Color Coding
Clear color coding ensures safe and accurate wiring. The cable features black cores with number marks. Alternatively, it uses black cores with number marks and a yellow/green core in the outer cover.

Constructive data NYY O/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter of cable approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
7 x 1,5 re 14,7 100 323
8 x 1,5 re 16,0 114 385
10 x 1,5 re 17,7 142 472
12 x 1,5 re 18,2 171 509
14 x 1,5 re 19,0 199 559
16 x 1,5 re 19,9 227 607
19 x 1,5 re 20,8 270 689
20 x 1,5 re 21,8 284 729
21 x 1,5 re 21,8 299 751
24 x 1,5 re 23,9 341 904
25 x 1,5 re 24,5 355 968
27 x 1,5 re 24,4 384 954
30 x 1,5 re 25,3 426 1030
37 x 1,5 re 27,0 526 1195
7 x 2,5 re 15,8 163 413
8 x 2,5 re 17,4 186 493
10 x 2,5 re 19,3 232 609

Constructive data NYY O/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter of cable approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
12 x 2,5 re 19,8 279 662
14 x 2,5 re 20,7 325 733
16 x 2,5 re 21,7 372 807
19 x 2,5 re 22,8 441 916
20 x 2,5 re 23,9 464 968
21 x 2,5 re 23,9 488 1001
24 x 2,5 re 26,2 557 1203
27 x 2,5 re 26,8 627 1278
30 x 2,5 re 27,8 697 1386
37 x 2,5 re 29,9 859 1641
7 x 4,0 re 19,3 261 639
8 x 4,0 re 21,3 299 766
10 x 4,0 re 23,8 373 950
12 x 4,0 re 24,5 448 1035
14 x 4,0 re 25,6 522 1147
16 x 4,0 re 26,9 597 1265
19 x 4,0 re 28,2 709 1440

Note: We manufacture other core configurations and special constructions upon request. Furthermore, we may produce cables with the same construction according to IEC 60502.

 

Factory Overview


Packaging & Shipping


Q1: What does the “NYY” designation mean, and where can this cable be installed?
A: The NYY 0.6/1 kV cable is a robust power cable designed for industrial and switching installations. It is suitable for secondary distribution networks, outdoor applications, indoor installations, open air, underground, and in water. However, you must avoid using it in areas where mechanical damage is anticipated.

Q2: What are the maximum temperature and voltage ratings for this cable?
A: This cable is rated for a maximum continuous conductor temperature of +70 °C. During a short circuit, it can withstand temperatures up to +160 °C for no more than 5 seconds. The rated voltage is 0.6/1 kV, and it has a test voltage of AC – 4 kV at 50 Hz.

Q3: How is the NYY cable constructed, and what materials are used?
A: The cable features solid or multi-strand copper conductors (Class 1 or 2 according to VDE 0295/IEC 60228). These are insulated with PVC type DIV4. A filling compound or tapes form the inner sheath, and the entire cable is protected by a durable black PVC outer sheath (type DMV5). The construction strictly follows VDE 0276 part 627 standards.

Q4: How can I identify the different cores inside the cable?
A: Core identification follows VDE 0293 standards. The cable features black cores with number marks. Alternatively, it uses black cores with number marks and a yellow/green earth core in the outer cover.

Q5: What is the minimum bending radius required during installation?
A: To ensure the cable’s integrity, the minimum bending radius during installation is 15 times the cable diameter for multi-core cables, or 12 times the cable diameter for single-core cables.

Q6: Is this cable flame retardant?
A: Yes. The NYY cable is tested for flame propagation and meets the VDE 0472 part 804 class B and IEC 332 part 1 standards, ensuring safety in demanding environments.

Q7: Are custom core configurations available?
A: Yes. While standard configurations are listed in the constructive data tables, we manufacture other core configurations and special constructions upon request. Additionally, cables with the same construction may be produced according to IEC 60502 standards.

Reviews

There are no reviews yet.

Be the first to review “NYY 0.6/1 kV Low voltage Control Cable – Solid & Stranded Copper for Industrial Use”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS