AGKABEL Flame Retardant Single Core Cables – FRT-H, FRT-XH, FRT-XAH (XLPE/XLEVA, LSZH, 600/1000V)

AGKABEL Flame Retardant Single Core Cables (FRT-H, FRT-XH, FRT-XAH) are 600/1000V power cables designed to restrict flame propagation and enhance safety in critical environments. Featuring plain annealed copper conductors and a choice of XLPE (90°C) or XLEVA (110°C) insulation, they are built with LSZH (Low Smoke Zero Halogen) bedding and sheathing to minimize toxic smoke. Available in non-sheathed (FRT-H), unarmoured (FRT-XH), and Aluminium Wire Armoured (FRT-XAH) options, these cables meet stringent standards including IEC 60332-3 for flame retardance and IEC 61034 for low smoke emission. They are ideal for power distribution in public buildings, tunnels, and industrial plants where fire safety is paramount.

AGKABEL GRUPPE LIMITED presents its Flame Retardant Single Core Cables, available in three distinct configurations to meet diverse installation requirements: FRT-H (Insulated, Non-Sheathed), FRT-XH (Unarmoured), and FRT-XAH (Armoured). Engineered for power distribution in environments where fire safety is critical, these cables are designed to restrict flame propagation and minimize toxic smoke emissions.

The cables feature Plain Annealed Copper conductors (Class 2 stranding) and are insulated with either XLPE (rated up to 90°C) or XLEVA (rated up to 110°C). For maximum safety, the FRT-XH and FRT-XAH variants utilize a LSZH (Low Smoke Zero Halogen) bedding and outer sheath, which significantly reduces toxic gas and dense black smoke during a fire. The FRT-XAH variant includes an Aluminium Wire Armour, offering additional mechanical protection against impact and rodent damage for demanding installations.

Technical Data

  • Conductor: Plain Annealed Copper (Class 2)

  • Insulation: (a) XLPE Compound or (b) XLEVA Compound

  • Bedding: LSZH Compound (FRT-XH & FRT-XAH)

  • Armouring: Aluminium Wire (FRT-XAH only)

  • Sheath: LSZH Compound (Black)

  • Colour: Insulation – Natural

  • Reference Standard: IEC 60502 / BS 6724 / BS 7211

  • Test Standards:

    • Flame Retardance: IEC 60332-3, BS 4066

    • Halogen & Smoke: IEC 60754, IEC 61034, BS 7622-Part 2, BS 6425

  • Voltage Uo/U: 600/1000V

  • Operating Temperature: (a) Max 90°C for XLPE, (b) Max 110°C for XLEVA

  • Minimum Bending Radius: 8D for unarmoured cable, 10D for armoured cable.

Technical Specifications Table

Nominal Conductor Area (mm²) No. & Dia. of Wires (no./mm) FRT-H Radial Thick. of Insulation (mm) FRT-H Cable Overall Dia. (mm) FRT-XH Radial Thick. of Insulation (mm) FRT-XH Cable Overall Dia. (mm) FRT-XAH Dia. Under Armour (mm) FRT-XAH Armour Wire Dia. (mm) FRT-XAH Cable Overall Dia. (mm)
1 x 1.5 7/0.53 0.7 3.1 0.7 6 – – –
1 x 2.5 7/0.67 0.8 3.7 0.7 6.4 – – –
1 x 4 7/0.85 0.8 4.3 0.7 7.0 – – –
1 x 6 7/1.04 0.8 4.8 0.7 7.5 – – –
1 x 10 7/1.35 1.0 6.2 0.7 8.5 – – –
1 x 16 7/1.70 1.0 7.2 0.7 9.5 – – –
1 x 25 7/2.14 1.2 9.0 0.9 11.2 – – –
1 x 35 7/2.52 1.2 10.0 0.9 12.4 – – –
1 x 50 19/1.78 1.4 11.9 1.0 14 – – –
1 x 70 19/2.14 1.4 13.7 1.1 16 15.4 1.25 21.5
1 x 95 19/2.52 1.6 16.0 1.1 18 17.3 1.25 23.4
1 x 120 37/2.03 1.6 17.6 1.2 20 19.1 1.6 25.9
1 x 150 37/2.25 1.8 19.6 1.4 22 21.1 1.6 27.9
1 x 185 37/2.52 2.0 21.8 1.6 24.4 23.2 1.6 30.1
1 x 240 61/2.25 2.2 24.4 1.7 27.5 26.2 1.6 33.2
1 x 300 61/2.52 2.4 27.7 1.8 30.3 28.8 1.6 35.8
1 x 400 61/2.85 2.6 31.1 2.0 33.9 32.7 2.0 40.9
1 x 500 61/3.20 2.8 34.6 2.2 37.6 36.2 2.0 44.6
1 x 630 127/2.52 2.8 38.6 2.4 42.4 40.6 2.0 49.2
1 x 800 127/2.85 – – 2.6 47.3 45.7 2.5 55.7
1 x 1000 127/3.20 – – 2.8 52.4 50.6 2.5 61.0

(Note: The table provides an extract of the dimensions. Weight columns have been omitted for visual clarity but are available in the full datasheet upon request.)

Factory Overview


Packaging & Shipping


Fly

Frequently Asked Questions (FAQ)

Q1: What is the difference between FRT-H, FRT-XH, and FRT-XAH?
A:

  • FRT-H: Insulated, non-sheathed. Best for internal wiring where an outer sheath is not required.

  • FRT-XH: Unarmoured. Includes a LSZH bedding and outer sheath for environmental and mechanical protection.

  • FRT-XAH: Armoured. Features a robust Aluminium Wire Armour for maximum mechanical protection against impact, crushing, and rodent damage.

Q2: Are these cables “Fire Resistant” or “Flame Retardant”?
A: These are Flame Retardant cables. They are designed to prevent the spread of fire (meeting IEC 60332-3) and emit minimal smoke and no halogens. They do not contain a Mica tape barrier, so they are not rated to maintain circuit integrity during a direct fire (unlike our Fire Resistant FR series).

Q3: Why are LSZH materials used?
A: LSZH (Low Smoke Zero Halogen) bedding and sheathing are crucial for safety. In a fire, they emit less toxic, corrosive gas and significantly less smoke compared to standard PVC. This protects people and sensitive electronic equipment.

Q4: What is the operating temperature range?
A: It depends on the insulation selected:

  • XLPE Insulation: Max continuous operating temperature of 90°C.

  • XLEVA Insulation: Max continuous operating temperature of 110°C.

Q5: What is the voltage rating of this series?
A: These cables are rated for 600/1000V.

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Flame Retardant Single Core Cables – FRT-H, FRT-XH, FRT-XAH (XLPE/XLEVA, LSZH, 600/1000V)”

Your email address will not be published. Required fields are marked *