AGKABEL Fire Resistant Instrumentation Cables – FR-XlOL (Unarmoured) & FR-XlOSL (Armoured) – Individually & Overall Screened

AGKABEL Fire Resistant Instrumentation Cables (FR-XlOL & FR-XlOSL) are advanced, double-screened multi-pair cables designed for mission-critical environments where signal integrity and fire survival are paramount. Featuring both individual pair screening and an overall screen, they provide unmatched protection against electromagnetic interference (EMI) and crosstalk. Built with a Mica Tape fire barrier, XLPE or XLEVA insulation, and a Low Smoke Zero Halogen (LSZH) sheath, these cables ensure continuous operation during a fire. Available in an unarmoured (FR-XlOL) or Galvanized Steel Wire Armoured (FR-XlOSL) design, they are fully compliant with IEC 60331, BS 5308, and BS 7629 standards.

AGKABEL GRUPPE LIMITED presents the FR-XlOL and FR-XlOSL series of Fire Resistant Instrumentation Cables, the ultimate solution for critical control systems that demand both fire survival and uncompromised signal integrity. Designed for complex industrial environments, these multi-pair cables feature a sophisticated double-screening design: each individual pair is wrapped in an Aluminium/Polyester tape, followed by an overall Aluminium/Polyester tape screen. Both screens include a 0.5mm² Tinned Drain Wire. This dual-layer protection completely eliminates crosstalk between pairs and shields against external electromagnetic interference (EMI).

At the heart of the cable is a Mica Tape fire barrier wrapped around Plain Annealed Copper (Class 2) conductors. When exposed to intense heat, the mica forms a ceramic-like crust, preventing short circuits and ensuring emergency systems remain operational. Insulation options include XLPE (90°C) or XLEVA (110°C), and the cable is sheathed in LSZH (Low Smoke Zero Halogen) compounds for maximum safety during a fire. The FR-XlOL variant is unarmoured, while the FR-XlOSL features a robust Galvanized Steel Wire Armour for severe mechanical protection.

Technical Data

  • Conductor: Plain Annealed Copper (Class 2 Stranding)

  • Fire Barrier: Mica Tape

  • Insulation: (a) XLPE Compound or (b) XLEVA Compound

  • Individual Screen: Aluminium/Polyester Tape with 0.5mm² (7/0.3mm) Tinned Drain Wire

  • Overall Screen: Aluminium/Polyester Tape with 0.5mm² (7/0.3mm) Tinned Drain Wire

  • Bedding: LSZH Compound

  • Armouring: Galvanized Steel Wire (FR-XlOSL only)

  • Sheath: LSZH Compound (Orange)

  • Colour: Insulation – White and Black with numberings.

  • Reference Standard: IEC 60502 / BS 5308 / BS 7629

  • Test Standards: IEC 60331 (Cat A, B, C), BS 6387 (C, W, Z), SS299 (C, W, Z), IEC 60332-3, BS 4066, IEC 60754, BS 6425, IEC 61034, BS 7622-Part 2.

  • Voltage Uo/U: 300/500V

  • Operating Temperature: (a) Max 90°C for XLPE, (b) Max 110°C for XLEVA.

  • Minimum Bending Radius: 8D for unarmoured, 10D for armoured.

Technical Specifications Table

Nominal Conductor Area (mm²) No. & Diameter of Wires (no./mm) Radial Thick. of Insulation (mm) FR-XlOL Cable Overall Dia. (mm) FR-XlOL Approx. Weight (kg/km) FR-XlOSL Dia. Under Armour (mm) FR-XlOSL Armour Wire Dia. (mm) FR-XlOSL Cable Overall Dia. (mm) FR-XlOSL Approx. Weight (kg/km)
2 Pairs
2P x 1.0 7 / 0.43 0.6 15.2 166 15.2 0.90 20.0 555
2P x 1.5 7 / 0.53 0.7 17.0 205 17.0 1.25 22.7 769
2P x 2.5 7 / 0.67 0.8 19.2 350 19.2 1.25 24.9 938
5 Pairs
5P x 1.0 7 / 0.43 0.6 17.5 335 17.5 1.25 23.2 1000
5P x 1.5 7 / 0.53 0.7 21.5 433 21.5 1.60 28.1 1352
5P x 2.5 7 / 0.67 0.8 24.0 592 24.0 1.60 30.8 1665
10 Pairs
10P x 1.0 7 / 0.43 0.6 22.5 626 22.5 1.60 29.3 1800
10P x 1.5 7 / 0.53 0.7 28.0 811 28.0 1.60 35.0 2165
10P x 2.5 7 / 0.67 0.8 31.5 1132 31.5 2.00 39.5 3007
20 Pairs
20P x 1.0 7 / 0.43 0.6 30.5 1143 30.5 2.00 38.5 3019
20P x 1.5 7 / 0.53 0.7 38.0 1509 38.0 2.00 46.2 3684
20P x 2.5 7 / 0.67 0.8 42.5 2112 42.5 2.50 51.9 5107

(Note: Other conductor sizes & core configurations are available upon request.)

Factory Overview


Packaging & Shipping


Fly

Frequently Asked Questions (FAQ)

Q1: What does the “I” in FR-XlOL stand for, and how does it differ from standard FR-XOL?
A: The “I” stands for Individual screen. Unlike the FR-XOL (which only has an overall screen), the FR-XlOL features an aluminium/polyester screen over each individual pair, plus an overall screen. This dual screening provides maximum protection against both internal crosstalk and external electromagnetic interference (EMI).

Q2: What is the primary application for double-screened instrumentation cables?
A: They are ideal for highly sensitive control and measurement systems, such as those found in petrochemical plants, power stations, and complex fire alarm networks, where transmitting accurate signals without interference is absolutely critical.

Q3: What is the difference between FR-XlOL and FR-XlOSL?
A:

  • FR-XlOL: The unarmoured version, offering flexibility for standard routing.

  • FR-XlOSL: Includes a Galvanized Steel Wire Armour. The ‘S’ in the designation indicates this extra layer of mechanical protection against impact, crushing, and rodent damage, suitable for harsh environments or direct burial.

Q4: How does the Mica Tape ensure the cable works during a fire?
A: The Mica Tape is wrapped directly over the copper conductors. Under intense heat, the mica compound turns into a hard, ceramic-like insulating crust. This prevents the conductors from short-circuiting, allowing emergency power and signals to continue flowing.

Q5: What do the reference standards BS 5308 and BS 7629 guarantee?
A:

  • BS 5308: Ensures the cable meets the strict electrical and physical requirements for instrumentation cables.

  • BS 7629: Certifies that the cable can maintain circuit integrity and continue to function during a fire, making it suitable for life safety systems.

Q6: Why is the outer sheath colored Orange?
A: The Orange sheath is a universally recognized safety color used to quickly identify Fire Resistant cables, ensuring they are easily distinguished from standard power or data cables during installation and maintenance.

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Fire Resistant Instrumentation Cables – FR-XlOL (Unarmoured) & FR-XlOSL (Armoured) – Individually & Overall Screened”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS