AGKABEL UL AWM Style 2464 Multi-Conductor Cable is a flexible, PVC-insulated and PVC-jacketed control and signal cable recognized under UL 758 (AWM) and commonly certified to CSA standards. Rated at 300V and 80°C, it is available with 2 to 12+ color-coded conductors in sizes from 28 AWG to 16 AWG. Standard constructions feature stranded copper conductors and a flexible PVC jacket, with UL VW-1 / CSA FT1 flame ratings. Shielded variants (foil or braid) are available for EMI protection. Ideal for internal wiring of electronic equipment, control panels, PLC systems, and RS-232/422/485 serial communication, it is the perfect solution for protected, low-voltage signal and control circuits. Not intended for continuous flexing or outdoor exposure.
AGKABEL UF-B Underground Feeder and Branch Circuit Cable – 600V
Heavy-duty, direct-burial rated cable designed for underground feeders to outside post lamps, pumps, and other loads. May also be used for interior branch circuit wiring in residential or agricultural buildings (limited to 60°C ampacity). Features annealed (soft) copper conductors, PVC insulation, and a sunlight-resistant PVC jacket. Compliant with ASTM B-3, B-8, UL83, and UL493. Voltage rating: 600V. Available in 2-conductor and 3-conductor configurations with or without ground wire, from AWG 6 to 14.
AGKABEL GRUPPE LIMITED presents the UF-B (Underground Feeder and Branch Circuit Cable), engineered for reliable power distribution in outdoor and underground applications. This cable is specifically designed for direct burial and is generally used as a feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building, as specified in the National Electrical Code. Multiple conductor UF-B cable may also be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors). It can be used in applications permitted for NMC in Section 334.10(B) of the NEC.
Technical Data
-
Standard: ASTM – B3 and B-8, UL83, UL493
-
Voltage: 600V
-
Conductor: Annealed (soft) copper, solid or compressed stranded
-
Insulation: Phase conductors are PVC insulated, nylon jacket
-
Jacket: PVC jacketed (sunlight-resistant)
-
Application: Generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
Technical Specifications Table
Two Conductor
| Conductor Size (AWG) | No. of strands | Insulation Thickness (mils) | Ground Wire Size (AWG) | Sheath Diameter (mils) | Max. DC Resistance at 20°C (Ohm/km) | Approx. weight (1000′ lbs) |
|---|---|---|---|---|---|---|
| 2C*14 | 1 | 19 | 14 | 423 X 168 | 8.79 | 70 |
| 2C*12 | 1 | 19 | 12 | 463 X 183 | 5.41 | 95 |
| 2C*12 | 1 | 19 | Without Ground | 386 X 183 | 5.41 | 70 |
| 2C*10 | 1 | 24 | 10 | 518 X 215 | 3.64 | 138 |
| 2C*8 | 7 | 35 | 10 | 678 X 302 | 2.36 | 222 |
| 2C*6 | 7 | 35 | 10 | 770 X 338 | 1.44 | 305 |
Three Conductor
| Conductor Size (AWG) | No. of strands | Insulation Thickness (mils) | Ground Wire Size (AWG) | Sheath Diameter (mils) | Max. DC Resistance at 20°C (Ohm/km) | Approx. weight (1000′ lbs) |
|---|---|---|---|---|---|---|
| 3C*14 | 1 | 19 | 14 | 581 X 168 | 8.79 | 95 |
| 3C*12 | 1 | 19 | 12 | 626 X 183 | 5.41 | 129 |
| 3C*12 | 1 | 19 | Without Ground | 581 X 183 | 5.41 | 107 |
| 3C*10 | 1 | 24 | 10 | 727 X 215 | 3.64 | 191 |
| 3C*8 | 7 | 35 | 10 | 1059 X 319 | 2.36 | 344 |
| 3C*6 | 7 | 35 | 10 | 1223 X 361 | 1.44 | 478 |
Factory Overview
Packaging & Shipping
❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for this cable?
It is generally used as a feeder to outside post lamps, pumps, and other loads from a distribution point. It is also suitable for direct burial underground and for interior branch circuit wiring in residential or agricultural buildings.
2. Can this cable be buried directly in the ground?
Yes, UF-B cable is specifically designed for direct burial without the need for conduit.
3. What is the voltage and temperature rating?
The voltage rating is 600V. For interior branch circuit wiring, the conductor temperature must not exceed 90°C, but the ampacity is limited to that of 60°C conductors.
4. What materials are used for insulation and the jacket?
The phase conductors are PVC insulated with a nylon jacket, and the overall cable has a sunlight-resistant PVC jacket.
5. What sizes and configurations are available?
Available in 2-conductor and 3-conductor configurations, with or without a ground wire, ranging from AWG 6 to AWG 14.
6. What standards does this cable comply with?
It complies with ASTM B-3 and B-8, UL83, and UL493.