RE-2X(St)Y-fr XLPE Insulated Flame Retardant Control Cable – EN 50288

The RE-2X(St)Y-fr cable delivers dependable data transmission for measuring and control appliances. Constructed with bare copper conductors, XLPE insulation, a static aluminum tape screen with a tinned copper wire, and a black flame retardant PVC outer sheath, it offers exceptional signal integrity and fire safety. Because it meets standards similar to EN 50288 and is RoHS compliant, it provides a safe and reliable solution for fixed installations in dry, wet, and outdoor wall environments.

Application
RE-2X(St)Y-fr cables provide reliable data transfer for measuring and control appliances. Because of their static screen, installers use them to protect circuits from external interfering signals. Furthermore, these cables are suitable for fixed installation in dry and wet premises, as well as for outdoor installation on the walls of buildings. Additionally, they are specifically designed for environments where the non-proliferation of flames is required.

Cable construction
This cable adheres to standards similar to EN 50288. It features bare copper conductors according to IEC 60228 with nominal areas of 0.5mm² (7×0.3mm), 0.75mm² (7×0.43mm), and 1.3mm² (7×0.48mm), class 2. The insulation uses an XLPE compound according to IEC 60502-1. Core identification includes numbered black/white cores (1/1, 2/2, etc.). Each pair is twisted, with pairs stranded into layers of polyester tapes. A wrapping screen of aluminum tape (coated with polyester and one tinned copper wire 0.5mm²) forms the static screen. Finally, a black PVC compound flame retardant outer sheath protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 Ω/km for 0.5 mm², 24.6 Ω/km for 0.75 mm², and 14.2 Ω/km for 1.3 mm². The mutual capacitance at 800 Hz is max. 55 nF/km (0.5 mm²), 60 nF/km (0.75 mm²), and 70 nF/km (1.3 mm²). The insulation resistance is min. 5 GΩ.km. The maximum conductor temperature is 70 °C. The test voltage is 50 Hz, 1 min for 1500V (wire-wire) and 500V (wire-screen). The temperature range is fixed -5 °C to +50 °C and mobile -40 °C to +70 °C. The minimum bending radius is 7.5 x cable diameter. Furthermore, it passes the flame retardance test according to IEC 60332-1, IEC 60332-3, class C.

Type codes
RE = control cable, 2X = XLPE insulation, (St) = static screen, Y-fr = sheath of special PVC, flame retardant.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data RE – 2X(St)Y-fr

Number of pairs External diameter approx. Copper weight Cable weight approx.
1x2x0,5mm² mm kg/km kg/km
1 7,5 14 78
2 8,2 23 97
4 11,0 42 151
8 13,4 80 226
12 15,6 117 297
16 17,3 155 364
20 18,9 192 429
24 20,3 230 493
36 24,0 342 679
48 27,0 455 857
1x2x0,75mm²
1 8,0 20 90
2 8,7 33 115
4 12,0 60 191
8 14,7 115 280
12 17,2 165 366
16 19,2 216 463
20 21,0 265 513
24 22,6 325 620
36 26,8 475 745
48 30,3 625 889
1x2x1,3mm²
1 6,7 35 65
2 8,9 59 113
4 11,9 118 196
8 15,3 225 350
12 18,2 335 486
16 20,6 445 648
20 22,7 558 779
24 24,7 669 918

Factory Overview



Packaging & Shipping



Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the RE-2X(St)Y-fr cable?
A:- It is used for data transfer in measuring and control appliances, protecting circuits from external interfering signals in dry, wet, and outdoor wall installations.

Q:- What are the key fire safety features of this cable?
A:- It features a PVC flame retardant outer sheath and passes the IEC 60332-1 and IEC 60332-3 class C flame retardance tests.

Q:- What standards does the cable construction follow?
A:- The construction adheres to standards similar to EN 50288, and the conductor complies with IEC 60228 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses bare copper conductors with an XLPE compound insulation according to IEC 60502-1.

Q:- What is the maximum conductor temperature for this cable?
A:- The maximum conductor temperature is 70°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz ranges from 55 nF/km (0.5 mm²) to 70 nF/km (1.3 mm²).

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 1500V (wire-wire) and 500V (wire-screen).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 7.5 times the cable diameter.

Q:- What do the type codes RE, 2X, (St), and Y-fr stand for?
A:- RE indicates a control cable, 2X indicates XLPE insulation, (St) indicates a static screen, and Y-fr indicates a special PVC flame retardant sheath.

Q:- How is the static screen constructed?
A:- The static screen consists of a wrapping of aluminum tape coated with polyester and one tinned copper wire.