RE-2X(St)Y-fr PIMF XLPE Individually Screened Control Cable – EN 50288

The RE-2X(St)Y-fr PIMF cable delivers dependable data transmission for measuring and control appliances. Constructed with bare copper conductors, XLPE insulation, individually screened pairs (PIMF), an overall static screen, and a flame retardant PVC outer sheath, it offers exceptional signal integrity and fire safety. Because it meets standards similar to EN 50288 and is RoHS compliant, it provides a safe and reliable solution for fixed installations in dry, wet, and outdoor wall environments.

Application
RE-2X(St)Y-fr PIMF cables provide reliable data transfer for measuring and control appliances. Because of their individual and overall static screens, installers use them to protect circuits from external interfering signals. Furthermore, these cables are suitable for fixed installation in dry and wet premises, as well as for outdoor installation on the walls of buildings. Additionally, they are specifically designed for environments where the non-proliferation of flames is required.

Cable construction
This cable adheres to standards similar to EN 50288. It features bare copper conductors according to IEC 60228 with nominal areas of 0.5mm² (7×0.3mm), 0.75mm² (7×0.43mm), and 1.3mm² (7×0.48mm), class 2. The insulation uses an XLPE compound according to IEC 60502-1. Core identification includes numbered black/white cores (1/1, 2/2, etc.). Each wire is twisted to a pair with PIMF construction: a drain wire (0.6 mm, tinned Cu), an Al-PET foil, and a metal tape as the individual screen, with a wrapping of plastic foil. The PIMF pairs are stranded into layers with 1 orange communication wire. A wrapping screen of aluminum tape (coated with polyester and a tinned copper wire) provides overall static shielding. Finally, a PVC compound flame retardant outer sheath (black or other color) protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 Ω/km (0.5 mm²) and 14.2 Ω/km (1.3 mm²). The mutual capacitance at 800 Hz is max. 55 nF/km. The insulation resistance is min. 5 GΩ.km. The maximum conductor temperature is 70 °C. The test voltage is 50 Hz, 1 min for 1500V (wire-wire) and 500V (wire-screen). The rated cable voltage is Uo/U 300/500V. The temperature range is mobile -5 °C to +50 °C and fixed -40 °C to +70 °C. The minimum bending radius is 7.5 x cable diameter. Furthermore, it passes the flame retardance test according to IEC 60332-3, class C.

Type codes
RE = control cable, 2X = XLPE insulation, (St) = static screen, Y-fr = sheath of special PVC, flame retardant, PIMF = screened pairs.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data RE – 2X(St)Y-fr

Number of pairs External diameter approx. Copper weight Cable weight approx.
1x2x0,5mm² PIMF mm kg/km kg/km
1 9,6 31 105
2 11,7 38 138
4 12,5 61 171
8 14,7 122 248
12 17,7 165 355
1x2x1,3mm² PIMF
1 7,6 35 65
2 13,5 65 185
4 15,5 122 275
8 20,2 232 460
12 21,5 352 589

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the RE-2X(St)Y-fr PIMF cable?
A:- It is used for data transfer in measuring and control appliances, protecting circuits from external interfering signals in dry, wet, and outdoor wall installations.

Q:- What are the key features of the PIMF construction?
A:- PIMF (screened pairs) features individual pair screens made of a drain wire, Al-PET foil, and metal tape, combined with an overall static screen for superior protection against interference.

Q:- What standards does the cable construction follow?
A:- The construction adheres to standards similar to EN 50288, and the conductor complies with IEC 60228 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses bare copper conductors with an XLPE compound insulation according to IEC 60502-1.

Q:- What is the maximum conductor temperature for this cable?
A:- The maximum conductor temperature is 70°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 55 nF/km.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 1500V (wire-wire) and 500V (wire-screen).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 7.5 times the cable diameter.

Q:- What do the type codes RE, 2X, (St), Y-fr, and PIMF stand for?
A:- RE indicates a control cable, 2X indicates XLPE insulation, (St) indicates a static screen, Y-fr indicates a special PVC flame retardant sheath, and PIMF indicates screened pairs.

Q:- What is the rated cable voltage?
A:- The rated cable voltage is Uo/U 300/500V.

Reviews

There are no reviews yet.

Be the first to review “RE-2X(St)Y-fr PIMF XLPE Individually Screened Control Cable – EN 50288”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS