PVC/PVC/SWA/HDPE Armoured Paired Control Cable – ESI 09-6

The PVC/PVC/SWA/HDPE cable delivers dependable communication and control connections for industrial and infrastructure applications. Constructed with solid tinned copper conductors, PVC insulation, twisted pairs, steel wire armour, and a black HDPE outer sheath, it offers exceptional mechanical protection and signal integrity. Because it meets standards similar to ESI 09-6 and is RoHS compliant, it provides a safe and reliable solution for outdoor and underground installations.

Application
PVC/PVC/SWA/HDPE cables provide reliable communication and control connections for industrial and infrastructure applications. Because of their steel wire armour and durable HDPE outer sheath, installers use them in outdoor applications and underground where mechanical damage is not anticipated. Consequently, they deliver consistent performance in physically demanding environments.

Cable construction
This cable adheres to standards similar to ESI 09-6, issue 5. It features a solid tinned copper conductor with a diameter of 0.6 mm. The insulation uses a PVC type TI1 compound (according to BS 6746) with a nominal radial thickness of 0.2 mm. Each pair is twisted, with pairs stranded into layers with a minimum of 1 layer of plastic tape. A PVC compound type TM1 forms the inner sheath. A single layer of galvanized steel wires (according to BS 1442) provides the armour. The outer sheath uses a PE compound type HDPE in black color. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 39 MΩ/km. The insulation resistance is min. 50 MΩ.km. The mutual capacitance at 800 Hz is max. 120 nF/km. The capacitance unbalance at 800 Hz is max. 270 pF/500m. The test voltage is 50 Hz, 1 min for 3000V (wire-wire) and 5000V (all wire – earth). The operating voltage peak value is 150V. The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +70 °C. The minimum bending radius is 15 x cable diameter.

Cable core construction
The pairs are arranged in layers: 2 pairs (2(quad)), 5 pairs (5 in 1st layer), 10 pairs (2 in 1st layer, 6 in 2nd layer), etc., up to 100 pairs.

Color coding
Clear color coding ensures safe and accurate wiring. The a-wire colors include black, blue, orange, green, brown, grey, white, red, violet, yellow, and turquoise. The b-wire colors follow a similar pattern, with specific pairing for identification.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data PVC/PVC/SWA/HDPE x2x1/0.6

Number of pairs Diameter of armour wire External diameter approx. Copper weight Cable weight approx.
mm mm kg/km kg/km
2x2x1/0.6 0,9 8,4 11 158
5x2x1/0.6 0,9 10,9 27 229
10x2x1/0.6 0,9 12,7 55 303
20x2x1/0.6 0,9 15,4 105 466
30x2x1/0.6 1,25 18,1 160 672
50x2x1/0.6 1,25 21,8 265 924
100x2x1/0.6 1,6 29,8 530 1731

Factory Overview



Packaging & Shipping



Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the PVC/PVC/SWA/HDPE cable?
A:- It is used in outdoor applications and underground where mechanical damage is not anticipated, providing reliable communication and control connections.

Q:- What are the key mechanical protection features of this cable?
A:- It features a single layer of galvanized steel wires (SWA) for mechanical protection and a durable HDPE outer sheath for environmental resistance.

Q:- What standards does the cable construction follow?
A:- The construction adheres to standards similar to ESI 09-6, issue 5.

Q:- What type of conductor and insulation does it use?
A:- It uses a solid tinned copper conductor with a PVC type TI1 insulation according to BS 6746.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +50°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 120 nF/km.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 3000V (wire-wire) and 5000V (all wire – earth).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.

Q:- What is the conductor resistance at 20°C?
A:- The conductor resistance at 20°C is max. 39 MΩ/km.

Q:- How are the pairs arranged in the cable core?
A:- The pairs are stranded into layers, starting with a 2-pair quad and expanding up to 100 pairs across multiple layers.