PTPV 2×0.5 Telephone Wire for Indoor and Outdoor Use

This telephone wire is engineered for connecting telephones and loudspeakers to city and local telephone lines. It features a bare copper conductor with solid PE insulation and a durable PVC sheath in white. Designed for both indoor and outdoor laying, the two parallel laid cores with different colors ensure easy identification. With a rated operating voltage of 100V and an insulation resistance of 200 MΩ.km, it provides reliable signal transmission for telecommunications infrastructure.

The PTPV telephone cable is specifically used for connecting telephones and loudspeakers to terminal equipments of city and local telephone and radio relay system lines. Because it is designed for both indoor and outdoor laying, it is exceptionally versatile for various telecommunications infrastructure projects. Furthermore, the cable features two parallel laid cores with different colors that are unified with a PVC sheath, ensuring durability and easy identification during installation.

The wire structure features a bare copper conductor with a diameter of 0.5mm, which is insulated with solid PE insulation according to BDS 1006-82. The cable is protected by a PVC sheath in a white color, according to BDS 5792-84, ensuring resistance to environmental factors.

Technical Data & Construction Overview:

  • Conductor diameter: 0.5mm

  • Conductor resistance at 20°C – max: 95 Ω/km

  • Insulation resistance: 200 MΩ.km (measured at temperature 20 +/- 5°C, after 2 hours in water)

  • Rated operating voltage with frequencies 50Hz, V: 100V

  • Tested voltage: 500V (applied for a period of 2 min between each core and between both wires)

  • Temperature range during exploitation and storage: -30°C up to +50°C

Color coding

Two different colored cores

Type codes

  • P – wire

  • T – telephone

  • P – PE insulation

  • V – PVC sheath

Construction data

No. x mm Outer diameter approx. max. mm x mm Copper weight kg/km Cable weight approx. kg/km
2×0.5 4.4 3.6 22

Factory Overview


Packaging & Shipping


Frequently asked questions and answer (Q:- A:-)

Q:- What is the primary application of the PTPV 2×0.5 cable?
A:- It is used for connecting telephones and loudspeakers to terminal equipment of city and local telephone lines.
Q:- Is this cable suitable for outdoor use?
A:- Yes, it is designed for both indoor and outdoor laying.
Q:- What is the conductor diameter of this telephone wire?
A:- The bare copper conductor has a diameter of 0.5mm.
Q:- What is the maximum conductor resistance at 20°C?
A:- The maximum conductor resistance is 95 Ω/km.
Q:- What is the insulation resistance of this cable?
A:- The insulation resistance is 200 MΩ.km.
Q:- What is the rated operating voltage?
A:- The rated operating voltage with frequencies 50Hz is 100V.
Q:- What is the test voltage for this wire?
A:- The tested voltage is 500V applied for 2 minutes.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PVC in a white color.
Q:- What is the temperature range during exploitation and storage?
A:- The temperature range is -30°C up to +50°C.
Q:- How are the cores identified?
A:- The two parallel laid cores have different colors for easy identification.