PMVSUR & PMVS Installation Cables for Information Processing Systems
These installation cables are engineered for electrical communication groups and information processing systems. They feature tinned copper conductors with PVC insulation, available in single, stranded, pair, triple, and quad configurations. Designed for internal electrical installation, they ensure reliable signal transmission with a maximum conductor temperature of 70°C. The cables are strictly not intended for high-power installation systems.
These installation cables are specifically designed with copper tinned conductors and PVC insulation for use in electrical installation and equipment. Because they are intended for internal electrical installation and installation systems of electrical communication groups and equipment, they are highly versatile for modern infrastructure. Furthermore, they serve as processing information systems, providing reliable signal transmission. However, it should be noted that these cables are not to be used for high-power installation systems, and the maximum allowed long-time conductor temperature is 70°C.
The cable structure features a tinned copper conductor with diameters of 0.4 mm, 0.5 mm, 0.6 mm, or 0.8 mm, which is insulated with PVC insulation class 1 according to BDS 5750-84. The wires are configured based on the specific type: PMVS cables feature 2 wires twisted into a pair, 3 wires twisted into a triple, or 4 wires twisted into a quad. Meanwhile, PMVSUR cables feature single or stranded configurations. The color coding is designed for easy identification, with PMVSUR utilizing white, brown, green, yellow, grey, pink, and red wires, while PMVS utilizes white, brown, green, yellow, and red.
Technical Data & Construction Overview:
-
Conductor diameter: 0.4 mm / 0.5 mm / 0.6 mm / 0.8 mm
-
Conductor resistance at 20°C – max: 144 Ω/km / 92 Ω/km / 64 Ω/km / 36 Ω/km
-
Insulation resistance – min: 300 MΩ.km (for 0.4, 0.5, 0.6 mm); 300 MΩ.km (for 0.8 mm)
-
Nominal voltage, V: 380 / 380 / 380 / 600
-
Test alternating voltage 50Hz, 2 min, V: 1500 / 1500 / 1500 / 2500
Type codes
-
P – wire
-
M – PVC insulation
-
V – PVC insulation
-
S – for communication systems
-
U – single wire
-
R – for coupling
Construction data
| N x mm | Outer diameter approx. mm | Copper weight kg/km | Wire weight approx. kg/km |
|---|---|---|---|
| PMVSUR | |||
| 1×0.4 | 1.8 | 1.20 | 3.80 |
| 1×0.5 | 1.6 | 2.20 | 5.00 |
| 1×0.6 | 1.7 | 2.80 | 6.20 |
| 1×0.8 | 2.1 | 4.70 | 7.90 |
| PMVS | |||
| 2×0.4 | 3.0 | 1.20 | 7.40 |
| 2×0.5 | 3.0 | 2.20 | 10.10 |
| 2×0.6 | 3.4 | 2.80 | 12.10 |
| 2×0.8 | 4.2 | 4.70 | 18.20 |
| 3×0.4 | 3.0 | 1.80 | 8.60 |
| 3×0.5 | 3.0 | 3.20 | 12.00 |
| 3×0.6 | 3.5 | 3.70 | 13.70 |
| 3×0.8 | 4.8 | 7.10 | 21.10 |
| 4×0.4 | 3.3 | 2.40 | 16.50 |
| 4×0.5 | 3.7 | 3.30 | 17.00 |
| 4×0.6 | 4.0 | 5.60 | 25.50 |
| 4×0.8 | 5.0 | 8.40 | 32.50 |
| PMVS | |||
| 1×0.4 | 1.6 | 1.20 | 1.65 |
| 1×0.5 | 1.7 | 2.20 | 2.60 |
| 1×0.6 | 1.8 | 2.80 | 3.00 |
| 1×0.8 | 2.0 | 4.60 | 5.00 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of the PMVSUR and PMVS cables?
A:- They are used for electrical installation and equipment, specifically for electrical communication groups and processing information systems.
Q:- Can these cables be used for high-power installation systems?
A:- No, these cables are explicitly not to be used for high-power installation systems.
Q:- What is the maximum allowed long-time conductor temperature?
A:- The maximum allowed long-time conductor temperature is 70°C.
Q:- What type of conductor is used in these cables?
A:- They feature tinned copper conductors.
Q:- What is the conductor resistance for the 0.4 mm version?
A:- The maximum conductor resistance is 144 Ω/km.
Q:- What is the nominal voltage for the 0.8 mm version?
A:- The nominal voltage for the 0.8 mm version is 600V.
Q:- What is the test voltage for the 0.4 mm version?
A:- The test voltage is 1500V at 50Hz for 2 minutes.
Q:- How are the PMVS cables constructed?
A:- PMVS cables are constructed with 2 wires twisted into a pair, 3 wires twisted into a triple, or 4 wires twisted into a quad.
Q:- What is the insulation resistance for these cables?
A:- The minimum insulation resistance is 300 MΩ.km.
Q:- What is the wire weight for a PMVS 4×0.8 cable?
A:- The wire weight is approximately 32.50 kg/km.




Reviews