PE/SWA/PE Armoured Loop Feeder Cable – BS 6346/87 Standard

The PE/SWA/PE loop feeder cable delivers dependable electrical connections for fixed installations. Constructed with a solid copper conductor, PE insulation, steel wire armour, and an orange PE outer sheath, it offers exceptional mechanical protection. Because it meets BS 6346/87 standards and is RoHS compliant, it provides a safe and reliable solution for outdoor, indoor, open air, and underground installations where mechanical damage is anticipated.

Application
PE/SWA/PE loop feeder cables provide reliable electrical connections for fixed installations. Because they feature galvanized steel wire armour, installers use them in outdoor applications, indoor installations, in the open air, and underground where mechanical damage is anticipated. Consequently, they deliver consistent performance and robust protection in demanding physical environments.

Cable construction
This cable adheres to BS 6346/87 standards. It features a solid copper conductor according to BS 6360 with sizes of 1.5mm² (1/1.37mm) and 2.5mm² (1/1.76mm). The insulation uses a PE type 03 compound according to BS 6234. The cable core is wrapped with a minimum of 1 layer of plastic tape. A PE type 03 compound forms the inner sheath. A single layer of galvanized steel wires (according to BS 1442) provides the armour. Finally, a PE compound type 03 outer sheath (according to BS 6234) protects the entire assembly. The sheath color is orange. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 12.1 Ω/km for 1.5 mm² and 7.41 Ω/km for 2.5 mm². The insulation resistance is min. 5 GΩ.km. The mutual capacitance at 800 Hz varies by configuration (e.g., 52.5 nF/km for 2×1.5 mm²). The inductance is 585-685 μH/km, and 490-570 μH/km for 2.5 mm². The test voltage is 50 Hz, 1 min for 3500V (wire-wire and wire-armour). The voltage rating is 600/1000V. The temperature range is mobile -20 °C to +50 °C and fixed -10 °C to +70 °C. The minimum bending radius is 7.5 x cable diameter.

Color coding
Clear color coding ensures safe and accurate wiring. For 1 pair (2 wires), the colors are blue and brown. For 2 pairs (4 wires), the colors are blue, brown, black, and grey.

Type codes
2Y = insulation or sheath of PE, SWA = armour.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Mechanical data PE/SWA/PE

Number of wires Diameter of armour wire External diameter approx. Copper weight Cable weight approx.
mm mm kg/km kg/km
2×1.5mm² 0,9 11,4 27 230
4×1.5mm² 0,9 12,5 53 280
2×2.5mm² 0,9 12,5 43 290
4×2.5mm² 0,9 14,0 88 370

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the PE/SWA/PE loop feeder cable?
A:- It is used in outdoor applications, indoor installations, in open air, and underground where mechanical damage is anticipated.

Q:- What are the key mechanical protection features of this cable?
A:- It features a single layer of galvanized steel wires (SWA) that provides robust mechanical protection against damage.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 6346/87 standards, and the conductor complies with BS 6360.

Q:- What type of conductor and insulation does it use?
A:- It uses a solid copper conductor with a PE type 03 compound insulation.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -10°C to +70°C, and the mobile temperature range is -20°C to +50°C.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 3500V (wire-wire and wire-armour).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 7.5 times the cable diameter.

Q:- What is the voltage rating?
A:- The voltage rating is 600/1000V.

Q:- What is the conductor resistance at 20°C?
A:- The conductor resistance is 12.1 Ω/km for 1.5 mm² and 7.41 Ω/km for 2.5 mm².

Q:- What do the type codes 2Y and SWA stand for?
A:- 2Y indicates insulation or sheath of PE, and SWA indicates galvanized steel wire armour.