H05V-U/-K PVC Single-Core Cable – VDE 0281-3 & HD 21.3 S3
The H05V-U/-K cable delivers dependable electrical connections for internal wiring and protected installations. Constructed with flexible copper conductors and PVC insulation, it offers excellent flexibility and durability for switchboards, distribution boards, and lighting fixtures. Because it meets VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards and is CE/RoHS compliant, it provides a safe and reliable solution for installation in conduits, tubes, and under plaster.
Application
H05V-U/-K cables provide reliable electrical connections for internal wiring and protected installations. Because they feature flexible PVC insulation, installers use them extensively in switchboards, distribution boards, and lighting fixtures. Furthermore, they perform reliably in tubes, conduits, and under plaster. Additionally, they are ideal for bell circuits and signal systems where specific safety and flexibility are required.
Cable construction
This cable strictly adheres to VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards. It features copper wires according to VDE 0295 class 1 or 5 (IEC 60228). The insulation uses a PVC compound type YI1 according to VDE 0207 part 4. Available colors include black, red, blue, pink, grey, yellow, green, brown, white, violet, orange, and specific two-color combinations that are not permitted except for green/yellow. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 and IEC 60228. The maximum core temperature is 70 °C in operation. It operates at a rated voltage of 300/500 V and undergoes a test voltage of AC 50 Hz at 2000 V. The temperature range is mobile -5 °C to +70 °C and fixed -30 °C to +70 °C. Installers must respect a minimum bending radius of 10 times the cable diameter for diameters up to 10mm, and 15 times the cable diameter for larger sizes. Furthermore, it passes the flame test, class 5 according to VDE 0472 part 804 and IEC 60 332-1.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data H05V-U/-K 300/500 V
| Nominal cross section | Approx. outer diameter | Copper weight | Approx. cable weight |
|---|---|---|---|
| mm² | mm | kg/km | kg/km |
| H05V-U | |||
| 0,50 | 2,1 | 4,6 | 8,9 |
| 0,75 | 2,3 | 6,7 | 11,6 |
| 1,00 | 2,5 | 9,2 | 14,4 |
| H05V-K | |||
| 0,50 | 2,3 | 4,8 | 9,0 |
| 0,75 | 2,5 | 7,1 | 12,4 |
| 1,00 | 2,7 | 9,5 | 16,3 |
Factory Overview

Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the H05V-U/-K cable?
A:- It is used for internal wiring in electrical equipment and protected installations, including switchboards, distribution boards, lighting fixtures, and bell circuits.
Q:- Where can this cable be installed?
A:- It is suitable for installation in tubes, conduits, and under plaster, provided it is in a protected environment.
Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards, and the conductor complies with VDE 0295 and IEC 60228.
Q:- What type of conductor and insulation does it use?
A:- It uses copper wires (class 1 or 5) with a PVC compound type YI1 insulation.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +70°C.
Q:- What is the rated voltage and test voltage?
A:- The rated voltage is 300/500 V, and the test voltage is AC 50 Hz at 2000 V.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter for diameters up to 10mm, and 15 times for larger sizes.
Q:- What is the maximum core temperature?
A:- The maximum core temperature in operation is 70°C.
Q:- What are the color coding options available?
A:- Available colors include black, red, blue, pink, grey, yellow, green, brown, white, violet, and orange, with green/yellow permitted for two-color combinations.
Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test class 5 according to VDE 0472 part 804 and IEC 60 332-1.



Reviews
There are no reviews yet.