LSZH/LSZH Halogen-Free Paired Communication and Control Cable – ESI 09-6
The LSZH/LSZH cable delivers dependable communication and control connections for industrial and infrastructure applications. Constructed with solid tinned copper conductors, halogen-free polymer insulation, twisted pairs, and a halogen-free outer sheath, it offers exceptional fire safety with low smoke and zero halogen emissions. Because it meets ESI 09-6 standards and is RoHS compliant, it provides a safe and reliable solution for outdoor, indoor, and underground installations where human and equipment safety is critical.
Application
LSZH/LSZH cables provide reliable communication and control connections for industrial and infrastructure applications. Because they feature low smoke zero halogen (LSZH) materials, installers use them in outdoor applications, indoor installations, in open air, and underground. Furthermore, they are specifically designed for environments where particular protection against fire and life damage for human life and equipment is necessary.
Cable construction
This cable adheres to ESI 09-6, issue 6 standards. It features a solid tinned copper conductor with a diameter of 0.8 mm. The insulation uses a halogen-free polymer compound. Each pair is twisted, with pairs stranded into layers with a minimum of 1 layer of plastic tape. A halogen-free polymer compound forms the inner sheath (complying to BS 7655, part 6.1). The outer sheath also uses a halogen-free polymer compound (complying to BS 7655, part 6.1). Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 MΩ/km. The insulation resistance is min. 100 MΩ.km. The mutual capacitance at 800 Hz is max. 150 nF/km. The capacitance unbalance at 800 Hz is max. 270 pF/500m. The test voltage is 50 Hz, 1 min for 2000V (wire-wire). The operating voltage peak value is 150V. The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +70 °C. The minimum bending radius is 15 x cable diameter.
Cable core construction
The pairs are arranged in layers or units for larger counts. For instance, a 30-pair cable consists of one unit of 3×10-pair, one unit of 5×10-pair, and one unit of 2×20-pair. Units are identified by color tape: Unit 1 (Blue), Unit 2 (Orange), Unit 3 (Green), Unit 4 (Brown), and Unit 5 (Grey).
Color coding
Clear color coding ensures safe and accurate wiring. The 2-pair (quad cables) use white, red, blue, and orange. For multi-pair cables, the a-wire colors include white, black, red, etc., and the b-wire colors include blue, orange, green, etc.
Type codes
LSZH = halogen-free polymer compound.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Mechanical data LSZH/LSZH …x2x0.8
| Number of pairs | External diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|
| mm | kg/km | kg/km | |
| 1x2x0.8 | 7,1 | 10 | 65 |
| 2x2x0.8 | 7,9 | 19 | 83 |
| 5x2x0.8 | 11,3 | 47 | 165 |
| 10x2x0.8 | 14,3 | 93 | 269 |
| 15x2x0.8 | 15,9 | 140 | 350 |
| 20x2x0.8 | 18,1 | 186 | 451 |
| 30x2x0.8 | 21,5 | 280 | 622 |
| 40x2x0.8 | 24,1 | 375 | 788 |
| 50x2x0.8 | 28,0 | 470 | 966 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the LSZH/LSZH cable?
A:- It is used in outdoor applications, indoor installations, open air, and underground, particularly where protection against fire damage to human life and equipment is necessary.
Q:- What are the key fire safety features of this cable?
A:- It features halogen-free polymer compounds for both insulation and sheathing, providing low smoke and zero halogen properties to ensure safety during a fire.
Q:- What standards does the cable construction follow?
A:- The construction adheres to ESI 09-6, issue 6 standards, and the sheath compounds comply with BS 7655, part 6.1.
Q:- What type of conductor and insulation does it use?
A:- It uses a solid tinned copper conductor with a halogen-free polymer compound insulation.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +50°C.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 150 nF/km.
Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 2000V (wire-wire).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.
Q:- What is the conductor resistance at 20°C?
A:- The conductor resistance at 20°C is max. 36.8 MΩ/km.
Q:- How are the units identified in larger multi-pair cables?
A:- Each unit is lapped with colored tape for identification: Unit 1 (Blue), Unit 2 (Orange), Unit 3 (Green), Unit 4 (Brown), and Unit 5 (Grey).