AGKABEL Instrumentation Cables – 300V PLTC & 600V CPE Sheath
High-performance data and control cables designed for data transmission, operating data acquisition, entry control, and time recording systems. Available in 300V PLTC (PVC sheath, 105°C) and 600V Type TC (CPE sheath, 90°C) versions. Features stranded bare copper conductors and Aluminium/Polyester foil shields with a tinned copper drain wire. Options include Individual & Overall Shield (for superior crosstalk protection) and Overall Shield configurations. Suitable for indoor/outdoor installation in ducts or rack cable trays.
AGKABEL GRUPPE LIMITED presents a comprehensive range of Instrumentation Cables, engineered for reliable signal transmission in critical data acquisition and control systems. These cables are designed to meet strict industry standards (UL Subject 13 NEC Article 725 for PLTC, UL 1277 Type TC for 600V) and offer excellent protection against electromagnetic interference (EMI). The Individual & Overall Shield versions provide maximum protection by isolating each pair/triad, while the Overall Shield versions offer a compact solution for general EMI protection. Available with PVC sheaths (300V, 105°C) or rugged CPE sheaths (600V, 90°C) for harsh environments.
Technical Data (Summary)
-
Conductor: Stranded bare copper.
-
Insulation: PVC or FRPE (Flame Retardant Polyethylene), White/Black with number mark.
-
Shielding: Aluminium/Polyester foil (Individual and/or Overall) with 7/0.25mm Tinned Copper Drain Wire.
-
Communication Wire: 7/0.25mm TC with orange PVC (on 4-pair/triad or higher, PLTC versions).
-
Sheath: Flame Retardant PVC (PLTC, 105°C) or Flame-retardant CPE (600V TC, 90°C). Intrinsically Safe blue options available.
-
Application: Suitable for data transmission, operating data acquisition, entry control, and time recording systems. Indoor and outdoor installation in duct or rack cable tray.
Technical Specifications Tables
1. 300V PLTC – Individual & Overall Shield (PVC, 105°C)
| Number of Triad/AWG | No. of strands | Insulation Thick. (mm) | Drain Wire | Screen | Sheath Thick. (in) | Sheath OD (in) | Approx. Weight (lbs/Mft) |
|---|---|---|---|---|---|---|---|
| 2/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.050 | 0.490 | 105 |
| 4/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.050 | 0.540 | 165 |
| 8/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.740 | 285 |
| 12/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.930 | 435 |
| 16/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 1.020 | 560 |
| 24/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 1.230 | 680 |
| 36/18 | 7/0.34mm | 0.38 | 7/0.25mmTC | Al/foil | 0.080 | 1.390 | 1170 |
2. 300V PLTC – Overall Screened (PVC, 105°C)
| Number of Pairs/AWG | No. of strands | Insulation Thick. (mm) | Drain Wire | Screen | Sheath Thick. (in) | Sheath OD (in) | Approx. Weight (lbs/Mft) |
|---|---|---|---|---|---|---|---|
| 1/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.035 | 0.260 | 38 |
| 2/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.050 | 0.440 | 86 |
| 4/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.050 | 0.500 | 141 |
| 6/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.050 | 0.580 | 190 |
| 8/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.670 | 242 |
| 10/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.740 | 290 |
| 12/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.770 | 358 |
| 16/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.060 | 0.840 | 455 |
| 20/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 0.950 | 555 |
| 24/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 1.050 | 665 |
| 36/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 1.230 | 942 |
| 50/16 | 7/0.43mm | 0.38 | 7/0.25mmTC | Al/foil | 0.070 | 1.440 | 1294 |
3. 600V Type TC – Individual & Overall Shield (CPE Sheath, 90°C)
| Number of Pairs/AWG | No. of strands | Insulation Thick. (mm) | Drain Wire | Screen (IS+OS) | Sheath Thick. (in) | Sheath OD (in) | Approx. Weight (lbs/Mft) |
|---|---|---|---|---|---|---|---|
| 1/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.060 | 0.360 | 63 |
| 2/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.060 | 0.600 | 127 |
| 4/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.060 | 0.620 | 169 |
| 6/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.060 | 0.670 | 202 |
| 8/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.060 | 0.790 | 264 |
| 10/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.080 | 0.900 | 380 |
| 12/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.080 | 0.970 | 460 |
| 16/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.080 | 1.070 | 551 |
| 20/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.080 | 1.200 | 698 |
| 24/16 | 7/0.34mm | 0.64 | 7/0.25mm | Al/foil | 0.080 | 1.480 | 993 |
(Note: All TC drain wires are tinned copper. Weight based on copper strength of 70N/mm². Further dimensions available on request.)
Factory Overview
Packaging & Shipping

❓ Frequently Asked Questions (FAQ)
1. What is the difference between “Individual & Overall Shield” and “Overall Shield”?
-
Individual & Overall Shield: Each pair/triad has its own foil shield, plus an overall shield. This provides the highest level of protection against crosstalk and external EMI.
-
Overall Shield: A single foil shield surrounds all pairs. This is more compact and cost-effective for general EMI protection.
2. What is PLTC?
PLTC stands for Power Limited Tray Cable. It is a UL rating for cables installed in cable trays, raceways, or open wiring where the power is limited by a power source (e.g., Class 2 or Class 3 circuits).
3. What is the difference between the 300V PLTC and 600V TC versions?
-
300V PLTC: Rated 300V, PVC sheath, 105°C, UL Subject 13 NEC Article 725.
-
600V TC: Rated 600V, CPE sheath, 90°C, UL 1277 Type TC. The CPE sheath offers superior resistance to oil, chemicals, and harsh environments.
4. What is the purpose of the Communication Wire?
On the 300V PLTC versions (4-pair or higher), a 7/0.25mm TC communication wire with orange PVC insulation is included for additional signal or control requirements.
5. What standards do these cables comply with?
-
300V PLTC: UL listed Subject 13 NEC Article 725.
-
600V TC: UL 1277 Type Tray cable (TC).
6. What sizes and configurations are available?
Available in triad (300V) and pair (300V & 600V) configurations, with AWG sizes 16 and 18.



Reviews