FLR4Y PA Automotive Cable – Fuel Resistant Polyamide Insulated Cable
The FLR4Y PA automotive cable provides dependable electrical connections in automotive fuel systems. It features a tinned or bare copper concentric conductor and specialized polyamide insulation with outstanding fuel resistance. Furthermore, it operates within a rated temperature range of -40°C to +125°C. Available in FLR4Y-A and FLR4Y-B variants, this automotive cable is especially suitable for fuel gauge wiring applications.
Application
FLR4Y PA automotive cables provide reliable electrical connections in automotive fuel systems and vehicle wiring applications. Their specialized polyamide (PA) insulation offers outstanding fuel resistance, making them especially suitable for fuel gauge wiring.
Furthermore, the concentric copper conductor supports efficient electrical conductivity. The cable also features a wide operating temperature range, making it suitable for demanding automotive environments where fuel resistance is essential.
Cable Construction
-
Standard: TS16949.
-
Conductor: Tinned or bare copper conductor (concentric construction).
-
Insulation: PA (Polyamide).
-
Rated Temperature: -40°C to +125°C.
-
Sheath Marking: Manufacturer’s name (trademark) and type, production year/week or batch number, and metre markings.
-
Special Properties: Outstanding fuel resistance, especially suitable for fuel gauge wiring.
-
Available Types: FLR4Y-A and FLR4Y-B.
Technical Data
The FLR4Y PA automotive cable operates within a rated temperature range of -40°C to +125°C. Its specialized polyamide insulation provides outstanding fuel resistance for automotive fuel system applications.
Moreover, the cable comes in two construction variants: FLR4Y-A and FLR4Y-B. The FLR4Y-A features conductor cross-sections ranging from 0.35 mm² to 2.50 mm², while the FLR4Y-B offers cross-sections ranging from 0.35 mm² to 4.00 mm².
Constructive Data Table
FLR4Y-A
| Cross-section (mm²) | Conductor No. | Conductor Dia. (mm) | Insulation Thick. (mm) | Insulation Dia. (mm) | Max. Cond. Resistance at 20°C Bare/Tinned (Ω/m) | Weight (kg/km) |
|---|---|---|---|---|---|---|
| 0.35 | 7 | 0.25 | 0.20 | 1.30 | 47.8/54.5 | 4.2 |
| 0.50 | 19 | 0.19 | 0.22 | 1.60 | 34.1/38.2 | 5.8 |
| 0.75 | 19 | 0.23 | 0.24 | 1.90 | 22.7/25.4 | 8.0 |
| 1.00 | 19 | 0.25 | 0.24 | 2.10 | 17.0/19.1 | 11.0 |
| 1.50 | 19 | 0.32 | 0.24 | 2.40 | 11.7/13.0 | 15.0 |
| 2.50 | 19 | 0.40 | 0.28 | 3.00 | 7.0/7.8 | 24.0 |
FLR4Y-B
| Cross-section (mm²) | Conductor No. | Conductor Dia. (mm) | Insulation Thick. (mm) | Insulation Dia. (mm) | Max. Cond. Resistance at 20°C Bare/Tinned (Ω/m) | Weight (kg/km) |
|---|---|---|---|---|---|---|
| 0.35 | 12 | 0.20 | 0.20 | 1.40 | 47.8/54.5 | 4.2 |
| 0.50 | 16 | 0.20 | 0.22 | 1.60 | 34.1/38.2 | 5.8 |
| 0.75 | 24 | 0.20 | 0.24 | 1.90 | 22.7/25.4 | 8.0 |
| 1.00 | 32 | 0.20 | 0.24 | 2.10 | 17.0/19.1 | 11.0 |
| 1.50 | 30 | 0.25 | 0.24 | 2.40 | 11.7/13.0 | 15.0 |
| 2.50 | 50 | 0.25 | 0.28 | 3.00 | 7.0/7.8 | 24.0 |
| 4.00 | 56 | 0.30 | 0.32 | 3.70 | 4.32/4.8 | 40.0 |
Technical note: All table values and units remain unchanged from the original datasheet. However, the conductor resistance unit appears to be Ω/km rather than Ω/m. Please verify this with the manufacturer before publishing.
Factory Overview
Packaging & Shipping


Frequently Asked Questions and Answers
Q:- What is the primary application of the FLR4Y PA automotive cable?
A:- It is especially suitable for fuel gauge wiring and automotive electrical applications that require outstanding fuel resistance.
Q:- What standard is specified for the FLR4Y automotive cable?
A:- The manufacturer lists TS16949, an automotive quality management system standard, in the product datasheet.
Q:- What is the rated temperature range of the FLR4Y cable?
A:- The rated temperature range is -40°C to +125°C.
Q:- What type of conductor does the FLR4Y cable use?
A:- It uses a tinned or bare copper conductor with concentric construction.
Q:- What type of insulation does the FLR4Y automotive cable feature?
A:- It features PA (Polyamide) insulation with outstanding fuel resistance.
Q:- Is the FLR4Y automotive cable fuel resistant?
A:- Yes, its specialized polyamide insulation offers outstanding fuel resistance, making it especially suitable for fuel gauge wiring.
Q:- What is the difference between FLR4Y-A and FLR4Y-B cables?
A:- Both variants feature polyamide insulation and the same rated temperature range. However, they differ in conductor strand construction and available cross-section sizes.
Q:- What conductor cross-section sizes are available for FLR4Y-A?
A:- The FLR4Y-A cable is available in listed conductor cross-sections ranging from 0.35 mm² to 2.50 mm².
Q:- What conductor cross-section sizes are available for FLR4Y-B?
A:- The FLR4Y-B cable is available in listed conductor cross-sections ranging from 0.35 mm² to 4.00 mm².
Q:- What information is included in the sheath marking?
A:- The sheath marking includes the manufacturer’s name or trademark, cable type, production year/week or batch number, and metre markings.


Reviews