E-AY2Y-O & E-AY2Y-J 0.6/1 kV Aluminum Power Cable – PE Sheathed

The E-AY2Y-O and E-AY2Y-J 0.6/1 kV cables deliver dependable power distribution for industrial and secondary network applications. Constructed with solid or multi-strand aluminum conductors, PVC insulation, and a robust black PE outer sheath, they offer excellent protection against environmental factors. Because they are RoHS and CE compliant, they provide a safe and reliable solution for outdoor, underground, and in-water installations.

Application
E-AY2Y cables provide reliable power distribution in power plants, industrial settings, and switching installations. They also excel in secondary distribution networks. Because of their robust design, installers prefer them for outdoor applications, indoor installations, open air, underground, and even in water. However, you should not use them where mechanical damage is anticipated.

Cable construction
This cable strictly adheres to VDE 0276 part 603 and HD 603 S1 standards. It features solid or multi-strand aluminum wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses PVC type DIV1 according to HD 603 S1, while core identification follows VDE 0293. Finally, a black PE type DMP 2 sheath (acc. VDE 0276) protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for single-core cables, or 12 times for multi-core cables. Furthermore, it passes the flame test according to VDE 0472 part 804 class B (IEC 332 part 1).

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, or yellow/green. Double core cables feature blue and brown, or yellow-green and black.

Multi-Core Color Configurations

  • 3-core: brown, black, grey or yellow/green, blue, brown

  • 4-core: blue, brown, black, grey or yellow/green, brown, black, grey

  • 5-core: blue, brown, black, grey, black or yellow/green, blue, brown, black, grey

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data E-AY2Y o/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter of cable approx. Al weight Cable weight approx.
N x mm² mm kg/km kg/km
1 x 25,0 re 11,5 70 159
1 x 35,0 re 12,5 97 195
1 x 50,0 re 13,5 135 239
1 x 70,0 rm 15,1 195 339
1 x 95,0 rm 16,1 255 339
1 x 120,0 rm 18,2 270 447
1 x 150,0 rm 20,0 341 525
1 x 185,0 rm 22,1 526 722
1 x 240,0 rm 24,8 690 931
1 x 300,0 rm 27,1 863 1233
1 x 400,0 rm 30,1 1109 1397
1 x 500,0 rm 37,1 1461 2019
2 x 1,5 re 20,4 14 276
2 x 2,5 re 23,3 23 355
2 x 4,0 re 23,3 199 358
2 x 6,0 rm 26,9 269 507
2 x 10,0 rm 26,9 269 507
2 x 16,0 rm 30,0 398 753
2 x 25,0 rm 34,0 539 1045

Construction data E-AY2Y o/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter of cable approx. Al weight Cable weight approx.
N x mm² mm kg/km kg/km
3 x 25,0 re 21,7 210 475
3 x 35,0 re 23,6 281 585
3 x 50,0 sm 29,1 404 833
3 x 70,0 sm 29,2 584 1086
3 x 95,0 sm 32,0 809 1611
3 x 120,0 sm 36,0 1023 1716
3 x 150,0 sm 36,6 1235 2035
3 x 185,0 sm 38,8 1579 2571
3 x 240,0 sm 48,2 2071 3297
3 x 50,0+25 sm 28,0 462 950
3 x 70,0+35 sm 36,0 684 1337
3 x 95,0+50 sm 40,2 944 1738
3 x 120,0+70 sm 43,2 1218 2056
3 x 150,0+70 sm 48,2 1452 2487
3 x 185,0+95 sm 52,3 1848 3096
3 x 240,0+120 sm 58,7 2412 3839
3 x 300,0+150 sm 64,3 3008 4801

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.

Factory Overview


Packaging & Shipping


Q:- What is the application of E-AY2Y cables?
A:- E-AY2Y is used in power plants industrial and switching installations, in secondary distribution networks and other. These cables are preferably used in outdoor applications, for indoor installations, in the open air, underground and in water where mechanical damage is not anticipated.

Q:- What is the cable construction of the E-AY2Y cable?
A:-

  • Construction: According to VDE 0276 part 603

  • Conductor: Solid or multi-strand Al wires class 1 or 2 acc. VDE 0295 (IEC 60228)

  • Insulation: PVC type DIV1 acc. HD 603 S1

  • Core identification: According to VDE 0293

  • Sheath: PE type DMP 2 acc. VDE 0276

  • Color: Black

Q:- What are the technical data specifications for the E-AY2Y cable?
A:-

  • Conductor resistance at 20 °C: According to VDE 0295 class 1 or 2 (IEC 60228)

  • Max. conductor temperature: +70°C

  • Max. short circuit temperature: +160°C, not more than 5 sec

  • Rated voltage Uo/U: 0.6/1 kV

  • Test voltage: AC – 4 kV 50 Hz

  • Bending radius -single core: 15 cable diameter

  • Bending radius -multi core: 12 cable diameter

  • Flame test: VDE 0472 part 804 class B (IEC 332 part 1)

Q:- What is the color coding for the E-AY2Y cable?
A:-

  • Single core: Black, or yellow/green

  • Double core: Blue and brown or yellow-green and black

Reviews

There are no reviews yet.

Be the first to review “E-AY2Y-O & E-AY2Y-J 0.6/1 kV Aluminum Power Cable – PE Sheathed”

Your email address will not be published. Required fields are marked *