AYY-O & AYY-J 0.6/1 kV Aluminum Power Cable – IEC 60502-1
The AYY-O and AYY-J 0.6/1 kV cables deliver dependable power distribution for industrial and secondary network applications. Constructed with solid or multi-strand aluminum conductors, PVC insulation, and a black PVC outer sheath, they offer exceptional durability. Because they are RoHS and CE compliant, they provide a safe and reliable solution for outdoor, underground, and in-water installations.
Application
AYY cables provide reliable power distribution in power plants, industrial settings, and switching installations. They also excel in secondary distribution networks. Because of their robust design, installers prefer them for outdoor applications, indoor installations, open air, underground, and even in water. However, you should not use them where mechanical damage is anticipated.
Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features solid or multi-strand aluminum wires (class 1 or 2) that comply with IEC 60228. The insulation uses PVC type PVC/A according to IEC 60502, while core identification follows VDE 0293 (single core-black, multiple core). Finally, a black PVC type ST1 sheath (acc. IEC 60502) protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 1 or 2. The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 3.5 kV. Installers must respect a minimum bending radius of 18 times the cable diameter for single-core cables, or 12 times for multi-core cables. Furthermore, it passes the flame test according to IEC 332 part 1.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data AYY o/j 0.6/1 kV
| Number of wires and nominal cross section | Shape | Outer diameter approx. | Al weight | Cable weight approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 4 x 16,0 | rm | 20,3 | 180 | 460 |
| 4 x 25,0 | rm | 24,9 | 270 | 670 |
| 4 x 50,0 | sm | 28,9 | 520 | 1180 |
| 4 x 70,0 | sm | 31,7 | 730 | 1490 |
| 4 x 95,0 | sm | 36,0 | 1035 | 1810 |
Construction data AYY o/j 0.6/1 kV
| Number of wires and nominal cross section | Shape | Outer diameter approx. | Al weight | Cable weight approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 4 x 120,0 | sm | 40,6 | 1340 | 2210 |
| 4 x 150,0 | sm | 45,4 | 1650 | 2710 |
| 4 x 185,0 | sm | 49,8 | 2100 | 3320 |
| 4 x 240,0 | sm | 55,9 | 2770 | 4180 |
Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.
Factory Overview
Packaging & Shipping


Frequently asked questions and answer
Q:- What is the application of AYY cables?
A:- AYY is used in power plants industrial and switching installations, in secondary distribution networks and other. These cables are preferably used in outdoor applications, for indoor installations, in the open air, underground and in water where mechanical damage is not anticipated.
Q:- What is the cable construction of the AYY cable?
A:- Construction is according to IEC 60502-1. The conductor features solid or multi-strand Al wires class 1 or 2 acc. IEC 60228. It uses PVC type PVC/A acc. to IEC 60502 for insulation and core identification is single core-black, multiple core according to VDE 0293. The sheath is PVC type ST1 acc. IEC 60502 and the color is black.
Q:- What are the technical data specifications for the AYY cable?
A:- Conductor resistance at 20°C is according to IEC 60228 class 1 or 2. The max. conductor temperature is +70°C and the max. short circuit temperature is +160°C for not more than 5 sec. Rated voltage Uo/U is 0.6/1 kV with a test voltage of 3.5 kV. The bending radius is 18 cable diameter for single core and 12 cable diameter for multi core. The flame test is IEC 332 part 1.


Reviews