AGKABEL 1.9/3.3kV Aluminum XLPE 3C Heavy Duty Cable
High-voltage three-core cable designed for primary supply to urban networks. Features Compacted Annealed Aluminium conductors, TR-XLPE numbered cores, Annealed Copper Wire Heavy Duty screen, and a PVC 5V-90 or HDPE sheath. Compliant with AS/NZS 1429.1:2000. Max operating temperature: 90°C. Suitable for glanding and systems with high fault values (screen fault current rating of 13.1kA for 1 second). Available from 16mm² to 300mm².
AGKABEL GRUPPE LIMITED presents the 1.9/3.3kV Aluminum XLPE 3C Heavy Duty Cable, engineered for reliable primary power distribution in urban networks. Designed for unenclosed installation where not subject to mechanical damage, buried direct, or in underground ducts, this cable is ideal for systems having high fault values. The heavy-duty annealed copper wire screen provides excellent fault current capacity while the TR-XLPE insulation ensures superior thermal and electrical performance.
Construction & Standards
-
Standard: AS/NZS 1429.1:2000
-
Voltage: 1900/3300V (1.9/3.3kV)
-
Conductor: Compacted Annealed Aluminium
-
Insulation: TR-XLPE Numbered Cores
-
Screen: Annealed Copper Wire Heavy Duty
-
Sheath: PVC, 5V-90 or PVC, 5V-90 / HDPE
-
Max. Operating Temperature: 90°C
-
Sheath Marking: Manufacture name (trademark) and type, Production year/week or batch number, Metre-marked
Application
Primary supply to urban networks. Suitable unenclosed where not subject to mechanical damage, buried direct or in underground ducts. Suitable for glanding. Heavy duty screen – A minimum screen fault current rating of 13.1kA for 1 second but not exceeding the conductor rating.
Technical Specifications Table
| Conductor (mm²) | No. of strands | Dia. (mm) | Overall Diameter Min. (mm) | Overall Diameter Max. (mm) | Max. DC Resistance at 20°C (ohm/km) | Approximate Mass (kg/km) |
|---|---|---|---|---|---|---|
| 16 | 7 | 4.9 | 32.2 | 36.7 | 1.910 | 810 |
| 25 | 7 | 6.1 | 35.1 | 39.6 | 1.200 | 960 |
| 35 | 7 | 7.0 | 37.2 | 41.7 | 0.868 | 1160 |
| 50 | 19 | 8.1 | 39.7 | 44.3 | 0.641 | 1420 |
| 70 | 19 | 9.8 | 43.6 | 48.1 | 0.443 | 1820 |
| 95 | 19 | 11.6 | 47.9 | 52.5 | 0.320 | 2320 |
| 120 | 19 | 12.9 | 51.0 | 55.6 | 0.253 | 2760 |
| 150 | 19 | 14.3 | 54.2 | 58.9 | 0.206 | 3190 |
| 185 | 36 | 16.0 | 58.0 | 62.6 | 0.164 | 3610 |
| 240 | 36 | 18.4 | 63.6 | 68.3 | 0.125 | 4270 |
| 300 | 36 | 20.8 | 69.0 | 73.7 | 0.100 | 4940 |
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for this cable?
It is designed for primary supply to urban networks. It is suitable for unenclosed installation where not subject to mechanical damage, buried direct, or in underground ducts. It is also suitable for glanding and for systems having high fault values.
2. What is the maximum operating temperature?
The maximum operating temperature is 90°C.
3. What materials are used for the conductor and insulation?
The conductor is Compacted Annealed Aluminium. The insulation is TR-XLPE Numbered Cores.
4. What type of screen does this cable have?
It features an Annealed Copper Wire Heavy Duty screen with a minimum screen fault current rating of 13.1kA for 1 second (but not exceeding the conductor rating).
5. What is the voltage rating of this cable?
The voltage rating is 1.9/3.3kV (1900/3300V).
6. What standard does this cable comply with?
It complies with AS/NZS 1429.1:2000.
7. What sizes are available?
Available sizes range from 16mm² to 300mm².






Reviews
There are no reviews yet.