2XYRY-O/J & A2XYRY-O/J 0.6/1 kV XLPE Armoured Power Cable – IEC 60502-1

The 2XYRY-O/J and A2XYRY-O/J 0.6/1 kV cables deliver dependable power distribution for industrial installations and urban networks. Constructed with solid or stranded Cu/Al conductors, XLPE insulation, and steel wire armour, they offer excellent thermal and mechanical protection. Because they meet IEC 60502-1 standards and are RoHS compliant, they provide a safe and reliable solution for cable ducts, tunnels, and outdoor installations under shelters.

Application
2XYRY-O/J and A2XYRY-O/J cables provide reliable power and control distribution for industrial installations and urban networks. These cables operate with a nominal voltage Uo/U of 0.6/1 kV. Because of their robust design, installers use them for fixed assembly in lines with unlimited difference levels. Furthermore, they function well in cable ducts, tunnels, and conduits. Additionally, they perform reliably on shelves and grilles outdoors under shelters. Consequently, they deliver consistent performance in demanding infrastructure environments.

Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features solid or multi-strand aluminum or copper wires (class 1 or 2) that comply with IEC 60228. The insulation uses an XLPE compound for superior thermal resistance. Additionally, a PVC compound forms the inner sheath, and the armour consists of steel wires twisted concentrically. Finally, a PVC compound type ST2 sheath protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 1 or 2. The maximum conductor temperature reaches 90 °C for continuous operation. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage AC is applied for 5 minutes at 3.5 kV between cores and between core and screen. Installers must respect a minimum bending radius of 15 times the cable diameter. The laying temperature should not fall below 0 °C, and the explosion temperature ranges from -30 to 50 °C.

Color coding
Clear color coding ensures safe and accurate wiring. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences for easy identification.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

 

Construction data 2XYRY-O/J, A2XYRY-O/J 0.6/1 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Cable diameter approx. 2XYRY-O/J Mass of Cu approx. 2XYRY-O/J Cable weight approx. A2XYRY-O/J Mass of Al approx. A2XYRY-O/J Cable weight approx.
N x mm² mm mm mm kg/km kg/km kg/km kg/km
2 x 2,5 m 0,7 1,8 14,1 46 421 14 388
2 x 4 m 0,7 1,8 15,2 75 500 23 448
2 x 6 m 0,7 1,8 16,1 88 563 29 512
2 x 10 m 0,7 1,8 18,8 188 868 56 723
2 x 16 m 0,7 1,8 21,9 266 1150 89 931
2 x 25 m 0,9 1,8 24,9 485 1584 140 1235
2 x 35 m 0,9 1,9 26,2 645 2076 188 1730
2 x 50 m 1,0 2,1 29,2 908 2376 240 1727
3 x 1,5 m 0,7 1,8 16,5 78 468 17 417
3 x 2,5 m 0,7 1,8 16,5 70 619 21 570
3 x 4 m 0,7 1,8 17,5 70 719 38 658
3 x 6 m 0,7 1,8 18,8 168 769 51 676
3 x 10 m 0,7 1,8 19,8 282 987 85 785
3 x 16 m 0,7 1,8 21,3 447 1254 135 915
3 x 25 m 0,9 1,8 27,8 478 1830 210 1236
3 x 35 m 0,9 1,8 27,8 1010 2300 290 1593
3 x 70 m 1,0 1,9 33,8 1353 2801 385 1914
3 x 95 m 1,1 2,1 35,3 1968 3330 517 2237
4 x 2,5 m 0,7 1,8 16,6 93 509 26 467
4 x 4 m 0,7 1,8 17,5 149 690 42 606
4 x 6 m 0,7 1,8 18,8 230 820 58 754
4 x 10 m 0,7 1,8 21,2 176 1578 112 1309
4 x 16 m 0,7 1,8 23,5 595 2076 180 1832
4 x 25 m 0,9 1,9 27,5 570 2620 290 2030
4 x 33 m 1,0 2,1 30,3 846 3701 390 2737
4×50 m 1,0 2,1 34,0 1817 3301 520 2225
4×70 m 1,1 2,1 38,6 2672 4015 720 2940
4×95 m 1,6 2,1 43,0 3843 5075 1050 3430
4×120 sm 1,6 2,2 47,5 4367 7626 1340 4346
4×150 sm 1,8 2,4 51,8 5810 9141 1690 5094
4×185 sm 2,0 2,5 56,2 6960 10028 2050 5496
4×240 sm 2,2 2,6 62,3 9371 12861 2720 7207
7 x 1,5 m 0,7 1,8 17,0 9308 980 2720 789
7 x 2,5 m 0,7 1,8 19,1 109 1167 49 762
10 x 1,5 m 0,7 1,8 20,4 165 1193 51 717
12 x 1,5 m 0,7 1,8 20,4 165 2277 51 1179
19 x 2,5 m 0,7 1,8 25,6 435 2277 133 1972

Factory Overview



Packaging & Shipping


Reviews

There are no reviews yet.

Be the first to review “2XYRY-O/J & A2XYRY-O/J 0.6/1 kV XLPE Armoured Power Cable – IEC 60502-1”

Your email address will not be published. Required fields are marked *