2XYRaY-FR & A2XYRaY-FR 0.6/1 kV Flame Retardant Armoured Cable

The 2XYRaY-FR and A2XYRaY-FR 0.6/1 kV cables deliver dependable power distribution for industrial, domestic, and underground applications. Constructed with aluminum or copper conductors, XLPE insulation, aluminum wire armour, and a black flame retardant PVC outer sheath, they offer exceptional fire safety and mechanical protection. Because they meet IEC 60502-1 standards and are RoHS compliant, they provide a safe and reliable solution for power plants, switching installations, and secondary networks.

Application
2XYRaY-FR and A2XYRaY-FR cables provide reliable transfer and distribution of electrical power in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they require non-propagation of flames, installers use them widely in power plants, industrial and switching installations, and street lighting. Furthermore, they excel in domestic power supply connections and secondary distribution networks. Additionally, they are preferably used for underground application and as interior installation in rooms and cable ducts. Finally, they are suitable for outdoor applications where greater mechanical protection against accidental contact is required.

Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features solid or multi-strand aluminum or copper wires (class 1 or 2) that comply with IEC 60228. The insulation uses an XLPE compound. The inner sheath uses a PVC flame retardant compound of degree of flame retardancy. The armour consists of aluminum wires twisted concentrically. Finally, a black PVC flame retardant outer sheath of degree of flame retardancy category A protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 1 or 2. The maximum conductor temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of Uo/U 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage is AC – 5 min for 3.5 kV between cores and 3.5 kV between core and screen. Installers must respect a minimum bending radius of 15 times the cable diameter. The temperature of laying is no less than 0 °C. The temperature of explosion is -30 to 50 °C. Furthermore, it passes the flame retardancy test according to IEC 332-3, Category A.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XYRaY-FR, A2XYRaY-FR 0.6/1 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Cable diameter approx. 2XYRaY-FR Mass of Cu approx. 2XYRaY-FR Cable weight approx. A2XYRaY-FR Mass of Al approx. A2XYRaY-FR Cable weight approx.
N x mm² mm mm mm kg/km kg/km kg/km kg/km
1×25 m 0,9 1,8 12,4 243 532 68 370
1×35 m 0,9 1,8 13,3 337 657 90 425
1×50 m 1,0 1,8 14,4 480 853 127 498
1×70 m 1,1 1,8 15,7 656 1073 190 611
1×95 m 1,1 1,8 17,3 885 1417 260 785
1×120 m 1,2 1,8 18,8 1120 1707 305 866
1×150 m 1,3 1,8 20,9 1378 2028 405 1046
1×185 m 1,5 1,8 22,9 1700 2643 510 1371
1×240 m 1,7 2,0 26,2 2327 3355 665 1656
1×300 m 1,8 2,1 28,4 2857 4118 830 2010

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XYRaY-FR and A2XYRaY-FR cables?
A:- They are used for power transfer and distribution in power plants, industrial and switching installations, street lighting, domestic power supply connections, and secondary distribution networks.

Q:- What are the key features of this cable’s fire safety?
A:- It features a PVC flame retardant inner sheath and a black PVC outer sheath with a flame retardancy category A, passing the IEC 332-3 test.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-1 standards, and the conductor complies with IEC 60228 class 1 or 2.

Q:- What type of conductor and insulation does it use?
A:- It uses solid or multi-strand Al or Cu wires with XLPE insulation.

Q:- What kind of armour protects this cable?
A:- The cable features an armour made of aluminum wires twisted concentrically.

Q:- What is the rated voltage and maximum conductor temperature?
A:- The rated voltage is Uo/U 0.6/1 kV, and the maximum conductor temperature is 90°C continuous.

Q:- What are the short-circuit and overload temperature limits?
A:- It can withstand a short circuit temperature of 250°C for a maximum of 5 seconds and an overload temperature of 130°C for 100% per year max.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 5 min for 3.5 kV between cores and 3.5 kV between core and screen.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The temperature of laying is no less than 0°C, and the temperature of explosion is -30 to 50°C.

Reviews

There are no reviews yet.

Be the first to review “2XYRaY-FR & A2XYRaY-FR 0.6/1 kV Flame Retardant Armoured Cable”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS