NYFGY Medium Voltage Power Cable 6/10 kV, 12/20 kV, 18/30 kV

The NYFGY medium voltage power cable is engineered for energy distribution and fixed installation in buildings, concrete, water, and below ground. It features a robust copper conductor with XLPE insulation and a PVC outer sheath for reliable performance. Designed to withstand a permissible conductor temperature of +70°C and a minimum laying temperature of -5°C, it ensures safety and durability in demanding environments. Available in multiple voltage ratings and conductor sizes, it is ideal for urban and industrial power networks.

The NYFGY medium voltage power cables are specifically designed as energy distribution cables for fixed installation in buildings, including direct laying in concrete, water, and below ground. Because they are constructed with a permissible conductor temperature of +70°C and a minimum laying temperature of -5°C, they are exceptionally reliable for demanding power distribution infrastructure. Furthermore, the robust construction ensures long-term durability and safety in various environmental conditions, making them highly suitable for urban and industrial energy networks.

The cable structure features a copper conductor with a cross-section ranging from 3X25 RM to 3X300 SM, insulated with XLPE and protected by a PVC outer sheath. The medium voltage design ensures efficient and safe transmission of electrical energy across various distribution points.

Technical Data & Construction Overview:

  • Permissible conductor temperature: +70°C

  • Minimum laying temperature: -5°C

  • Min. permissible bending radius: 15 x diameter

Construction Data (Part Numbers & Specifications)

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
12101001 3,6/6kV 3X25 RM 37,0 720,00 2.500,00
12101002 3,6/6kV 3X35 RM 37,0 1.008,00 2.600,00
12101003 3,6/6kV 3X50 SM 39,0 1.440,00 3.100,00
12101004 3,6/6kV 3X70 SM 43,0 2.016,00 3.800,00
12101005 3,6/6kV 3X95 SM 46,0 2.736,00 4.700,00
12101006 3,6/6kV 3X120 SM 49,0 3.456,00 5.600,00
12101007 3,6/6kV 3X150 SM 52,0 4.320,00 6.500,00
12101008 3,6/6kV 3X185 SM 55,0 5.328,00 7.800,00
12101009 3,6/6kV 3X240 SM 59,0 6.912,00 9.900,00
12101010 3,6/6kV 3X300 SM 63,0 8.640,00 11.800,00

Further dimensions available on request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer (Q:- A:-)

Q:- What is the primary application of the NYFGY cable?
A:- It is used as an energy distribution cable for fixed installation in buildings, concrete, water, and below ground.
Q:- What is the permissible conductor temperature?
A:- The permissible conductor temperature is +70°C.
Q:- What is the minimum laying temperature?
A:- The minimum laying temperature is -5°C.
Q:- What is the minimum permissible bending radius?
A:- The minimum permissible bending radius is 15 times the cable diameter.
Q:- What is the voltage rating range for this cable family?
A:- The cable family is available in 6/10 kV, 12/20 kV, and 18/30 kV ratings.
Q:- What type of conductor is used in the NYFGY cable?
A:- It uses a copper conductor, available in round multi-wire (RM) or sectional multi-wire (SM) constructions.
Q:- Can this cable be laid directly in water?
A:- Yes, it is designed for direct laying in concrete, water, and below ground.
Q:- What is the copper weight for the 3X300 SM cable?
A:- The copper weight is 8,640.00 kg/km for the 3X300 SM cable.
Q:- What is the outer diameter of the 3X25 RM cable?
A:- The outer diameter is 37.0 mm for the 3X25 RM cable.
Q:- Are other dimensions available?
A:- Yes, further dimensions are available on request.

Reviews

There are no reviews yet.

Be the first to review “NYFGY Medium Voltage Power Cable 6/10 kV, 12/20 kV, 18/30 kV”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS