NYCY 0.6/1 kV Power Cable with Concentric Conductor – DIN VDE 0276

The NYCY cable delivers dependable energy distribution for fixed installations with enhanced earthing. Constructed with copper conductors, PVC insulation, a concentric copper conductor, and a robust PVC outer sheath, it offers excellent protection against interference and mechanical stress. Because it meets DIN VDE 0276 standards, it provides a safe and reliable solution for direct laying in concrete, water, and below ground.

Application
NYCY cables provide reliable energy distribution for fixed installations in buildings. Because they feature a concentric copper conductor, installers use them for direct laying in concrete, water, and below ground. Furthermore, this concentric design provides an integrated earth path and enhances protection against electromagnetic interference. Consequently, they deliver consistent, safe, and robust power transmission for demanding infrastructure projects.

Cable construction
This cable strictly adheres to DIN VDE 0276 part 603 standards. It features copper conductors. The insulation uses a PVC compound. A unique feature is the concentric conductor made of copper wires and copper tapes laid over the insulated cores. Finally, a durable PVC outer sheath protects the entire assembly.

Technical Data
The cable delivers consistent performance under specific conditions. The temperature range is -5 °C to +50 °C for flexing applications and -30 °C to +70 °C for fixed installations. The nominal voltage is 0.6/1 kV.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
12003001 2X1,5 RE/1,5 13,0 52,00 230,00
12003011 2X2,5 RE/1,5 14,0 60,00 300,00
12003022 2X4 RE/4 16,0 123,00 380,00
12003026 2X6 RE/6 18,0 162,00 480,00
12003009 2X10 RE/10 22,0 312,00 520,00
12003009 2X16 RE/16 25,3 489,00 720,00
12003002 3X1,5 RE/1,5 14,0 66,00 300,00
12003012 3X2,5 RE/1,5 14,0 104,00 350,00
12003023 3X4 RE/4 16,0 161,00 470,00
12003027 3X6 RE/6 18,0 240,00 580,00
12003036 3X10 RE/10 20,5 408,00 680,00
12003006 3X16 RE/16 24,6 643,00 1.010,00
12003003 4X1,5 RE/1,5 14,0 81,00 330,00
12003013 4X2,5 RE/1,5 16,0 128,00 400,00
12003024 4X4 RE/4 16,0 200,00 550,00
12003028 4X6 RE/6 19,0 297,00 650,00
12003000 4X10 RE/10 23,5 504,00 790,00
12003004 4X16 RE/16 25,9 796,00 1.060,00
12003005 3X1,5 RE/1,5 15,0 95,00 330,00
12003014 3X2,5 RE/1,5 16,0 152,00 400,00
12003037 3X4 RE/4 19,0 236,00 550,00
12003038 3X6 RE/6 20,0 355,00 4.700,00
12003066 7X1,5 RE/1,5 16,0 133,00 430,00
12003015 7X2,5 RE/1,5 17,0 200,00 530,00
12003025 7X4 RE/4 21,0 315,00 730,00
12003033 7X6 RE/6 22,0 470,00 790,00
12003060 12X6 RE/10 27,0 810,00 1.350,00
12003029 1X10 RE/10 11,0 216,00 315,00
12003044 2X10 RE/10 20,0 312,00 650,00
12003036 3X10 RE/10 20,5 408,00 770,00
12003047 4X10 RE/10 21,0 504,00 820,00
12003000 1X16 RE/16 12,0 336,00 435,00
12003045 2X16 RE/16 22,0 489,00 900,00
12003046 3X16 RE/16 23,0 843,00 1.100,00
12003048 4X16 RE/16 23,0 796,00 1.250,00
12003043 10×2+1,5 RE/10 23,0 403,00 1.210,00
12003031 2x2x1,5 RE/10 33,1 696,00 968,00
12003034 2x2x2,5 RE/2,5 30,0 1.204,00 2.045,00
12003034 50x2x1,5 RE/0,5 54,0 1.933,00 4.010,00

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the NYCY cable?
A:- It is used for energy distribution in fixed installations in buildings, as well as for direct laying in concrete, water, and below ground.

Q:- What is the function of the concentric conductor?
A:- The concentric copper conductor serves as an integrated earth path and provides excellent protection against electromagnetic interference.

Q:- What standards does this cable comply with?
A:- It complies with DIN VDE 0276 part 603 standards.

Q:- What is the nominal voltage?
A:- The nominal voltage is 0.6/1 kV.

Q:- What is the temperature range for this cable?
A:- The temperature range is -5°C to +50°C for flexing and -30°C to +70°C for fixed installation.

Q:- What materials are used for insulation and sheathing?
A:- The insulation and sheathing use robust PVC compounds designed for durability and environmental protection.

Q:- Can this cable be laid directly in water?
A:- Yes, it is designed for direct laying in water, as well as concrete and underground.

Q:- What is the largest configuration available in the provided table?
A:- The largest configuration shown is 50x2x1,5 RE/0,5 mm².

Q:- Are other dimensions available besides those listed?
A:- Yes, further dimensions are available upon request.

Q:- What type of conductor is used?
A:- It uses copper conductors, with the main cores often being solid or stranded, and a concentric layer of copper wires.