TZEmPBP … x4x0.9 & x4x1.2 Shielded Armoured Trunk Cable – BDS 5052-90
The TZEmPBP … x4x0.9 and x4x1.2 cables deliver dependable signal transmission for inter-city communication networks and telephone exchanges. Constructed with bare copper conductors, paper string insulation, a lead-containing sheath, a double-layer copper tape screen, steel tape armour, and a protective PE sheath, they offer high protection against interference and mechanical damage. Because they meet BDS 5052-90 standards and feature a low reduction factor, they provide a reliable solution for areas with high electromagnetic fields.
Application
TZEmPBP cables provide reliable signal transmission for inter-city cable communication networks and connection lines between automatic telephone exchanges. Because they feature copper tape screens and steel tape armour, installers use them where the transfer of low-frequency signals is required. Furthermore, these cables are specifically designed for laying in ditches where there is less force of strain and inclined terrain less than 45°. Additionally, they perform exceptionally well in areas with high electromagnetic fields due to their low reduction factor. However, using them for high voltage power installations is not permitted.
Cable construction
This cable strictly adheres to BDS 5052-90 standards and the TU “EKLABEL” specification. It features a bare copper conductor with a diameter of 0.9 mm or 1.2 mm. The insulation uses paper string insulation, over which a paper tape is applied. Four wires are twisted into a quad, and the quads are twisted into layers. A lead-containing sheath (with an antimony of 0.4 to 0.6%) forms the pad. A screen of two layers of copper tapes is applied. A polythene inner sheath forms the pad, followed by bitumen and impregnated cable paper. The armour consists of two steel tapes, and a protective PE sheath with low density and 2.5% carbon black completes the assembly.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 28.3 Ω/km (0.9 mm) and 15.854 Ω/km (1.2 mm). The insulation resistance is min. 12,000 MΩ.km. The mutual capacitance at 800 Hz is 34 nF/km (0.9 mm) and 35 nF/km (1.2 mm). Capacitance unbalances at 800 Hz for 0.9 mm are: K1 – max. 280 pF/425m, K2-3 – max. 700 pF/425m, K9-12 – max. 210 pF/425m, E1-2 – max. 700 pF/425m. Test voltage is 50 Hz, 2 min for 700 V (wire-wire) and 1000 V (wire-sheath) for 0.9 mm, and 1000 V (wire-wire) and 2000 V (wire-sheath) for 1.2 mm. The operating voltage peak value is 225 V. The reduction factor (inductive voltage 50 to 390 V and frequency 50 Hz) is no more than 0.3. The temperature range is 0 °C to +45 °C (laying and installing) and -30 °C to +50 °C (exploitation and storage). The minimum bending radius is 20 times the cable diameter.
Color coding
The color coding features side circuit 1 (a-wire: white, b-wire: red) and side circuit 2 (a-wire: green, b-wire: blue). In each layer, there is a quad with a supporting spiral and an inscription of the counting direction “yellow” in the supporting spiral.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data TZEmPBP…x4x0.9
| Number of quads | Number and thickness of copper tapes | Number and thickness of steel tapes | Outer diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|---|
| N x mm | N x mm | mm | kg/km | kg/km | |
| 7 | 2×0,2 | 2×0,5 | 28,1 | 392 | 1824 |
| 14 | 2×0,3 | 2×0,5 | 34,9 | 778 | 3027 |
| 24 | 2×0,3 | 2×0,8 | 40,2 | 1150 | 3923 |
| 30 | 2×0,3 | 2×0,8 | 43,4 | 1438 | 4453 |
| 37 | 2×0,3 | 2×0,8 | 47,0 | 1592 | 5040 |
Construction data TZEmPBP…x4x1.2
| Number of quads | Number and thickness of copper tapes | Number and thickness of steel tapes | Outer diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|---|
| N x mm | N x mm | mm | kg/km | kg/km | |
| 3 | 2×0,2 | 2×0,5 | 25,3 | 327 | 1530 |
| 4 | 2×0,2 | 2×0,5 | 26,6 | 446 | 1688 |
| 7 | 2×0,3 | 2×0,5 | 33,5 | 708 | 2722 |
| 12 | 2×0,3 | 2×0,8 | 39,1 | 1041 | 3694 |
| 14 | 2×0,3 | 2×0,8 | 40,4 | 1157 | 3844 |
| 19 | 2×0,3 | 2×0,8 | 43,3 | 1439 | 4446 |
| 24 | 2×0,3 | 2×0,8 | 48,0 | 1755 | 5297 |
| 27 | 2×0,3 | 2×0,8 | 50,5 | 1939 | 5696 |
| 30 | 2×0,3 | 2×0,8 | 50,9 | 2042 | 5976 |
| 37 | 2×0,3 | 2×0,8 | 54,5 | 2467 | 6815 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the TZEmPBP cable?
A:- It is used for inter-city cable communication networks and connection lines between automatic telephone exchanges, specifically in areas with high electromagnetic fields.
Q:- What are the key shielding and mechanical protection features of this cable?
A:- It features a double-layer copper tape screen, steel tape armour, and a protective PE sheath, providing a low reduction factor and robust mechanical protection.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 5052-90 standards and the TU “EKLABEL” specification.
Q:- What type of conductor and insulation does it use?
A:- It uses a bare copper conductor (0.9 mm or 1.2 mm diameter) with paper string insulation and an outer paper tape.
Q:- What is the temperature range for this cable?
A:- The temperature range is 0°C to +45°C for laying and installing, and -30°C to +50°C for exploitation and storage.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is 34 nF/km for the 0.9 mm variant and 35 nF/km for the 1.2 mm variant.
Q:- What is the test voltage for this cable?
A:- For 0.9 mm: 700 V (wire-wire) and 1000 V (wire-sheath). For 1.2 mm: 1000 V (wire-wire) and 2000 V (wire-sheath).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 20 times the cable diameter (20 x D cable).
Q:- What is the maximum reduction factor for this cable?
A:- The reduction factor is no more than 0.3 at an inductive voltage of 50-390 V and a frequency of 50 Hz.
Q:- Is this cable permitted for high voltage power installations?
A:- No, the use of these cables for high voltage power installations is not permitted.