The MKEmPBP … x4x1.2 cable delivers dependable signal transmission for trunk cable communication networks and telephone exchanges. Constructed with bare copper conductors, paper string insulation, a copper tape screen, steel tape armour, and a protective PE sheath, it offers high protection against interference and mechanical damage for signals up to 252 kHz. Because it meets BDS 5052-90 standards and features a low reduction factor, it provides a reliable solution for areas with high electromagnetic fields.

Application
MKEmPBP cables provide reliable signal transmission for the construction of trunk cable communication networks and connection lines between automatic telephone exchanges. Because they feature an advanced screen and robust armour, installers use them for multi-channel systems with a frequency range up to 252 kHz, especially in areas with high electromagnetic fields. Furthermore, they are specifically designed for use in areas with a high reduction factor. However, using these cables for high voltage power installations is not permitted.

Cable construction
This cable strictly adheres to BDS 5052-90 standards and the TU “EKLABEL” specification. It features a bare copper conductor with a diameter of 1.2 mm. The insulation uses paper string insulation, covered by a paper tape. Four wires are twisted into a quad, and the quads are twisted concentrically into layers. The layers are wrapped with several layers of paper tapes, followed by a lead-containing sheath (with an antimony of 0.4 to 0.6%). A screen of copper tapes is applied over the sheath. A polythene inner sheath forms the pad, followed by bitumen and impregnated cable paper. The armour consists of two steel tapes, and a protective PE sheath with 2.5% carbon black completes the assembly.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a resistance of side circuit at 31.7 Ω/km and a conductor diameter of 1.2 mm. The ohmic asymmetry is max. 0.1 Ω/425m, and the insulation resistance is min. 12,000 MΩ.km. The mutual capacitance at 800 Hz is 26.5 nF/km. Attenuation near the end between all side-circuits at 252 kHz is 62 dB/425 (90% of all combinations) and 57.6 dB/425 (100% of all combinations). Protection of far end between all side-circuits at 252 kHz is 70 dB/425 (90% of all combinations) and 66 dB/425 (100% of all combinations). Test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath). The reduction factor, inductive voltage 50-400 V and frequency 50 Hz, is no more than 0.3. The operating voltage peak value is 300 V. The temperature range is -5 °C to +50 °C (laying and installing) and -40 °C to +70 °C (exploitation and storage). The minimum bending radius is 20 times the cable diameter.

Color coding
The color coding features side circuit 1 (a-wire: blue, b-wire: white) and side circuit 2 (a-wire: red, b-wire: green). In each layer, there is a quad with a supporting spiral and an inscription of the counting direction “yellow” in the supporting spiral.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data MKEmPBP …x4x1.2

Number of quads Outer diameter approx. Copper weight Cable weight approx.
mm kg/km kg/km
4 36 765 3006

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the MKEmPBP cable?
A:- It is used for trunk cable communication networks and connection lines between automatic telephone exchanges, specifically in areas with high electromagnetic fields.

Q:- What are the key shielding and protection features of this cable?
A:- It features a copper tape screen over the lead sheath, steel tape armour, and a protective PE sheath, providing a high reduction factor and robust mechanical protection.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 5052-90 standards and the TU “EKLABEL” specification.

Q:- What type of conductor and insulation does it use?
A:- It uses a bare copper conductor with a diameter of 1.2 mm and paper string insulation with an outer paper tape.

Q:- What is the temperature range for this cable?
A:- The temperature range is -5°C to +50°C for laying and installing, and -40°C to +70°C for exploitation and storage.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is 26.5 nF/km.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 20 times the cable diameter (20 x D cable).

Q:- What is the maximum reduction factor for this cable?
A:- The reduction factor is no more than 0.3 at an inductive voltage of 50-400 V and a frequency of 50 Hz.

Q:- Is this cable permitted for high voltage power installations?
A:- No, the use of these cables for high voltage power installations is not permitted.