SAVBVn/A 0.6/1 kV Aluminum Flame Retardant Armoured Power Cable – FN KI 02.001-96

The SAVBVn/A 0.6/1 kV cable delivers dependable power distribution for industrial and commercial installations. Constructed with aluminum conductors, PVC insulation, a flame retardant filling, steel tape armour, and a black flame retardant PVC outer sheath, it offers exceptional fire safety and mechanical protection. Because it meets FN KI 02.001-96 standards, passes the BDS IEC 332-3/C2 Category A flame test, and is RoHS compliant, it provides a safe and reliable solution for electrical networks requiring non-proliferation of flames.

Application
SAVBVn/A cables provide reliable power transfer and distribution in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they feature aluminum conductors, steel tape armour, and flame retardant materials, installers use them for the fixed installation of electrical power networks and installations. Furthermore, they ensure safety in surroundings that require non-proliferation of flames. Consequently, they deliver consistent performance and robust mechanical protection in demanding industrial environments.

Cable construction
This cable strictly adheres to FN KI 02.001-96 standards. It features aluminum solid or twisted wires (class 1 or 2) that comply with BDS 904-84. The insulation uses a PVC compound according to BDS 5790-84. A filling with flame retardant properties forms the inner sheath. The armour consists of steel tapes. Finally, a black PVC flame retardant outer sheath of flame retardancy category A protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to BDS 904-84. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 4 kV (alternating) and 12 kV (direct). The temperature range for laying and installing is -5 °C, while the exploitation and storage range is -30 °C to +50 °C. The operating temperature reaches +70 °C. The short circuit temperature is +160 °C for no more than 5 seconds. Installers must respect a minimum bending radius of 10 times the cable diameter. Furthermore, it passes the flame retardant test according to BDS IEC 332-3/C2, Category A.

Color coding
Clear color coding ensures safe and accurate wiring. Conductors without a yellow/green earth core feature random colors for 1 core, brown and blue for 2 cores, brown, black, and blue for 3 cores, and blue, brown, black, and grey for 4 cores. Conductors with a yellow/green earth core feature yellow/green, blue, and brown for 3 cores, and yellow/green, brown, black, and grey for 4 cores. For 6 cores and above, black with number marking is used. The neutral conductor is always blue.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SAVBVn/A 0.6/1 kV

Number of cond. and nominal cross section Form of conductor Cable diameter approx. Mass of Al Mass of cable approx.
N x mm² mm kg/km kg/km
2 x 2,5 re 16,4 14 433
2 x 4,0 re 17,3 23 490
2 x 6,0 re 17,5 34 499
2 x 10 re 19,1 56 593
2 x 16 rm 23,1 90 812
2 x 25 rm 25,1 137 995
2 x 35 rm 27,7 190 1174
3 x 1,5 re 16,4 21 430
3 x 2,5 re 16,5 24 420
3 x 4,0 re 17,2 36 481
3 x 6,0 re 19,1 51 635
3 x 10 re 20,1 85 651
3 x 16 rm 22,1 135 794
3 x 25 rm 27,7 210 1193
3 x 35 rm 29,1 290 1324
3 x 50 sm 33,1 385 1868
3 x 70 sm 34,6 540 1866
3 x 95 sm 33,0 685 2655
3 x 120 sm 38,0 1035 3128
3 x 150 sm 44,2 1255 3194
3 x 185 sm 47,9 1680 3780
3 x 240 sm 53,3 2035 4600
3 x 300 sm 58,7 2380 5530
3 x 4,0+2,5 re/re 18,9 42 490
3 x 6,0+4,0 re/re 19,9 80 699
3 x 10+6,0 re/re 21,0 101 694
3 x 16+10 rm/re 23,2 165 798
3 x 25+16 rm/re 27,6 255 1185
3 x 35+16 rm/rm 27,1 355 1300
3 x 50+25 sm/rm 34,1 480 1734
3 x 70+35 sm/rm 38,0 660 2034
3 x 95+50 sm/rm 38,2 880 2194
3 x 120+70 sm/rm 42,4 1210 2684
3 x 150+70 sm/rm 50,2 1400 3221

Construction data SAVBVn/A 0.6/1 kV

Number of cond. and nominal cross section Form of conductor Cable diameter approx. Mass of Al Mass of cable approx.
N x mm² mm kg/km kg/km
3 x 185+95 sm/rm 54,5 1780 4425
3 x 240+120 sm/rm 60,9 2385 5482
3 x 300+150 sm/rm 66,7 2685 6554
4 x 2,5 re 17,5 28 431
4 x 4,0 re 18,6 43 528
4 x 6,0 re 19,8 68 613
4 x 10 re 21,5 113 769
4 x 16 rm 25,1 168 807
4 x 25 rm 29,1 280 1274
4 x 35 rm 31,9 390 2049
4 x 50 sm 35,0 520 2310
4 x 70 sm 38,2 760 2630
4 x 95 sm 42,4 1060 2844
4 x 120 sm 45,6 1340 4046
4 x 150 sm 50,2 1650 4921
4 x 185 sm 54,5 2100 6104
4 x 240 sm 60,9 2050 6650
4 x 300 sm 66,7 3320 7088
5 x 1,5 re 15,9 25 415
5 x 2,5 re 17,5 42 460
5 x 4,0 re 19,6 75 607
5 x 6,0 re 21,0 85 690
5 x 10 re 23,7 140 890
5 x 16 rm 25,7 225 1062
5 x 25 rm 31,7 345 1519
5 x 35 rm 33,2 420 1650
5 x 50 sm 40,1 850 2571
7 x 1,5 re 16,9 33 450
7 x 2,5 re 18,5 55 526
10 x 1,5 re 20,4 61 625
12 x 1,5 re 21,2 71 706
14 x 1,5 re 22,1 76 767
16 x 1,5 re 23,0 95 807
19 x 1,5 re 23,0 101 870
21 x 1,5 re 24,0 101 870
24 x 1,5 re 26,1 120 1017

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SAVBVn/A cable?
A:- It is used for the fixed installation of electrical power networks and installations, designed for environments requiring non-proliferation of flames and mechanical protection.

Q:- What are the key mechanical protection features of this cable?
A:- It features an armour made of steel tapes, providing robust protection against mechanical damage.

Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.001-96 standards, and the conductor complies with BDS 904-84.

Q:- What type of conductor and insulation does it use?
A:- It uses aluminum solid or twisted wires (class 1 or 2) with a PVC compound insulation according to BDS 5790-84.

Q:- What is the temperature range for this cable?
A:- The temperature range for laying and installing is -5°C, while the exploitation and storage range is -30°C to +50°C.

Q:- What is the maximum operating and short-circuit temperature?
A:- The operating temperature is +70°C, and the short-circuit temperature is +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV (alternating) and 12 kV (direct).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- How are cables with 6 cores and above identified?
A:- For 6 cores and above, black with number marking is used for identification.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SAVBVn/A 0.6/1 kV Aluminum Flame Retardant Armoured Power Cable – FN KI 02.001-96”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS