SVBT & SAVBT 3.6/6 kV Armoured Medium Voltage Cable – BDS 16291-85
The SVBT and SAVBT 3.6/6 kV cables deliver dependable power distribution for industrial plants and power stations. Constructed with copper or aluminum conductors, PVC insulation, a steel tape armour-screen, and a grey PVC outer sheath, they offer excellent mechanical protection for fixed installations. Because they meet BDS 16291-85 standards and are RoHS compliant, they provide a safe and reliable solution for cable ducts, underground, and outdoor installations under shelters.
Application
SVBT and SAVBT medium voltage cables provide reliable distribution of electrical power for the electrical supply of consumers. They operate efficiently with a nominal voltage of Uo/U 3.6/6 kV and a frequency of 50 Hz, in industrial plants. Furthermore, installers use them in distribution installations, electric power stations, and industrial systems. Because of their robust design, they are suitable for fixed assembly in lines with unlimited difference levels, indoor installations, cable ducts, conduits, and shafts. Additionally, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters.
Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features copper and aluminum stranded compacted conductors according to BDS 904 (IEC 60228) class 2. The insulation uses a PVC compound. The cable assembly features three insulated phases twisted with fillings and a tape support. A polymer material forms the inner sheath. The armour-screen consists of two steel tapes. Finally, a grey PVC compound type P-1 sheath protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904 (IEC 60228) class 2. The operating temperature reaches 70 °C continuous. It operates at a nominal voltage of Uo/U 3.6/6 kV, while the highest system voltage is not more than 7.2 kV. Test voltage is AC (+) – 5 min for 11 kV and DC (-) – 15 min for 28 kV. The minimum bending radius is 15 times the cable diameter. The temperature of laying is no less than -5 °C. The temperature of explosion is -30 to 50 °C. The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of cores in mm.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data SVBT, SAVBT 3.6/6 kV
| Number of conductors and nominal cross-section | Thickness of insulation | Armour equivalent to copper | Cable diameter approx. | SVBT Mass of Cu approx. | SVBT Mass of cable approx. | SAVBT Mass of Al approx. | SAVBT Mass of cable approx. |
|---|---|---|---|---|---|---|---|
| N x mm² | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| Uo/U 3.6/6 kV | |||||||
| 3x25m/16 | 3,4 | 6 | 57,2 | 700 | 2585 | 210 | 2150 |
| 3x35m/16 | 3,4 | 6 | 60,0 | 680 | 3155 | 290 | 2535 |
| 3x50m/16 | 3,4 | 6 | 60,0 | 680 | 3155 | 290 | 2535 |
| 3x70m/25 | 3,4 | 6 | 60,6 | 682 | 3160 | 405 | 2700 |
| 3x95m/35 | 3,4 | 6 | 45,6 | 2650 | 4980 | 810 | 3380 |
| 3x120m/35 | 3,4 | 6 | 48,6 | 3350 | 5880 | 1020 | 3810 |
| 3x150m/50 | 3,4 | 6 | 51,4 | 4245 | 6810 | 1255 | 4380 |
| 3x185m/50 | 3,4 | 6 | 55,1 | 5160 | 8175 | 1575 | 4830 |
| 3x240m/70 | 3,4 | 6 | 60,0 | 6720 | 10110 | 2035 | 5660 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SVBT and SAVBT cables?
A:- They are designed for the distribution of electrical power for the electrical supply of consumers in industrial plants, distribution installations, electric power stations, and industrial systems.
Q:- What are the key mechanical protection features of this cable?
A:- It features an armour-screen consisting of two steel tapes, providing robust protection for direct underground or exposed installations.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904 (IEC 60228) class 2.
Q:- What type of conductor and insulation does it use?
A:- It uses Cu and Al stranded compacted conductors with a PVC compound insulation.
Q:- What is the rated voltage and highest system voltage?
A:- The nominal voltage Uo/U is 3.6/6 kV, and the highest system voltage is not more than 7.2 kV.
Q:- What is the maximum continuous operating temperature?
A:- The continuous operating temperature reaches 70°C.
Q:- What is the test voltage for this cable?
A:- Test voltage is AC (+) – 5 min for 11 kV and DC (-) – 15 min for 28 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).
Q:- What are the temperature limits for laying and explosion?
A:- The temperature of laying is no less than -5°C, and the temperature of explosion is -30 to 50°C.
Q:- What is the maximum force of strain during laying?
A:- The maximum force of strain is 30NS for Al cores and 50NS for Cu cores, where N is the number of cores and S is the cross-section of cores in mm.