SHEa(v)P / SAHEa(v)P 6/10 kV & 12/20 kV XLPE Insulated Copper & Aluminium Conductor Medium Voltage Power Cable – BDS 2581-86
SHEa(v)P and SAHEa(v)P are medium voltage XLPE-insulated power cables designed for reliable electrical power transmission and distribution in urban networks, transformer substations, and industrial installations. Manufactured according to BDS 2581-86 and Additional 4, these cables feature stranded and compacted copper or aluminium conductors, semiconductive XLPE layers, water-absorbing tapes, and an aluminium foil radial moisture barrier with a copolymer layer. Finished with a protective black PE Type MDPE outer sheath, they provide reliable protection against moisture penetration and are suitable for underground installations, cable ducts, conduits, shafts, and industrial power distribution systems.
Application
SHEa(v)P and SAHEa(v)P single-core cables with XLPE (Cross-Linked Polyethylene) insulation are designed for the transmission and distribution of electrical power at nominal voltages of 6/10 kV and 12/20 kV, with a frequency of 50 Hz.
They are mainly used in urban and district electrical networks, transformer substations, small and medium industrial plants, and electrical power distribution systems.
These cables are suitable for fixed installation in lines with unlimited differences in level, indoor installations, cable ducts, conduits, shafts, and underground installations in ditches, as well as outdoor installations under shelters.
Cable Construction
Manufactured according to BDS 2581-86 and Additional No. 4.
-
Conductor: Stranded and compacted copper or aluminium conductor according to BDS 904 (IEC 60228), Class 2.
-
Inner semiconductive layer: Semiconductive XLPE compound.
-
Insulation: XLPE (Cross-Linked Polyethylene) compound.
-
Outer semiconductive layer: Semiconductive XLPE compound.
-
Water-resistant element: Layer of semiconductive water-absorbing tapes.
-
Metal screen and radial moisture protection: Aluminium foil with copolymer layer.
-
Metal screen equivalency: Aluminium foil, 25 mm², equivalent to copper 16 mm².
-
Outer sheath: PE compound, Type MDPE.
-
Outer sheath colour: Black.
-
Compliance: RoHS compliant.
Cable Type Identification
| Cable designation | Conductor material |
|---|---|
| SHEa(v)P | Copper |
| SAHEa(v)P | Aluminium |
Technical Data
| Parameter | Specification |
|---|---|
| Applicable standard | BDS 2581-86 + Additional 4 |
| Conductor standard | BDS 904 (IEC 60228), Class 2 |
| Conductor material | Copper / Aluminium |
| Conductor resistance at 20°C | According to BDS 904 (IEC 60228), Class 2 |
| Continuous operating temperature | +90°C |
| Overload temperature | +130°C / 100 hours per year maximum |
| Maximum short-circuit temperature | +250°C / 5 seconds maximum |
| Nominal voltage (Uo/U) | 6/10 kV; 12/20 kV |
| Highest system voltage (U) | 12 kV; 24 kV |
| AC test voltage | 15 kV; 30 kV |
| AC test duration | 5 minutes |
| DC test voltage | 48 kV; 98 kV |
| DC test duration | 15 minutes |
| Partial discharge at 2 × Uo | Maximum 5 pC |
| Minimum bending radius | 15 × D (cable diameter) |
| Minimum laying temperature | Not less than -20°C |
| Operating temperature range | -30°C to +50°C |
| Water penetration test | IEC 60502-2 Annex D |
Cable Construction Identification
| Component | Description |
|---|---|
| Conductor | Stranded and compacted Cu / Al |
| Conductor class | Class 2 |
| Inner conductor screen | Semiconductive XLPE |
| Insulation | XLPE |
| Outer insulation screen | Semiconductive XLPE |
| Water-blocking layer | Semiconductive water-absorbing tapes |
| Metallic screen / moisture barrier | Aluminium foil with copolymer layer |
| Screen equivalency | Al foil 25 mm² / Cu 16 mm² |
| Outer sheath | PE Type MDPE |
| Outer sheath colour | Black |
Colour Coding
-
Outer sheath colour: Black.
-
Individual core insulation colour coding is not specified in the supplied catalogue.
3. Construction Data Tables
All dimensions are in mm and all material and cable weights are in kg/km.
Column identification:
-
Ins. = Insulation thickness
-
Sheath = Outer sheath thickness
-
Screen = Nominal cross-section of screen
-
Dia. = Approximate cable diameter
-
Al = Aluminium weight
-
Cu = Copper weight
-
Cable = Approximate total cable weight
Construction Data – 6/10 kV
| Nominal construction | Ins. | Sheath | Screen | Dia. | SAHEa Al | SAHEa Cable | SHEa Cu | SHEa Al | SHEa Cable |
|---|---|---|---|---|---|---|---|---|---|
| 1×185rm/25 | 3.4 | 2.5 | 25 (Cu16) | 33 | 584 | 1150 | 1664 | 74 | 2315 |
Construction Data – 12/20 kV
| Nominal construction | Ins. | Sheath | Screen | Dia. | SAHEa Al | SAHEa Cable | SHEa Cu | SHEa Al | SHEa Cable |
|---|---|---|---|---|---|---|---|---|---|
| 1×95rm/25 | 5.5 | 2.5 | 25 (Cu16) | 32 | 334 | 989 | 854 | 74 | 1584 |
| 1×120rm/25 | 5.5 | 2.5 | 25 (Cu16) | 33.5 | 404 | 1064 | 1079 | 74 | 1774 |
| 1×150rm/25 | 5.5 | 2.5 | 25 (Cu16) | 35 | 479 | 1224 | 1329 | 74 | 2164 |
| 1×185rm/25 | 5.5 | 2.5 | 25 (Cu16) | 37 | 586 | 1384 | 1664 | 76 | 2554 |
Note: Values are transcribed from the supplied catalogue. The catalogue provides separate aluminium and copper conductor weight columns, including an aluminium weight column under the SHEa(v)P heading.
Factory Overview
Packaging & Shipping
Frequently Asked Questions (FAQ)
Q:- What is the primary application of SHEa(v)P and SAHEa(v)P cables?
A:- These cables are designed for medium-voltage electrical power transmission and distribution in urban networks, transformer substations, industrial plants, and electrical power stations.
Q:- What is the difference between SHEa(v)P and SAHEa(v)P cables?
A:- SHEa(v)P uses copper conductors, while SAHEa(v)P uses aluminium conductors. Both feature XLPE insulation, semiconductive layers, water-absorbing tapes, aluminium foil moisture protection, and PE outer sheathing.
Q:- What standards do these cables follow?
A:- They are manufactured according to BDS 2581-86 and Additional 4.
Q:- What type of conductor is used?
A:- Both variants use stranded and compacted Class 2 copper or aluminium conductors according to IEC 60228.
Q:- What insulation material is used?
A:- They use XLPE (Cross-Linked Polyethylene) insulation with inner and outer semiconductive layers.
Q:- What makes these cables water-resistant?
A:- They incorporate semiconductive water-absorbing tapes and an aluminium foil radial moisture barrier with a copolymer layer.
Q:- What type of metallic screen is used?
A:- The cables use aluminium foil with a nominal cross-section of 25 mm², equivalent to a copper screen of 16 mm².
Q:- What is the maximum continuous operating temperature?
A:- The maximum continuous conductor operating temperature is +90°C.
Q:- What is the maximum short-circuit temperature?
A:- The maximum short-circuit temperature is +250°C for a maximum of 5 seconds.
Q:- What voltage ratings are available?
A:- The cables are available in 6/10 kV and 12/20 kV voltage ratings.
Q:- Are these cables tested for water penetration?
A:- Yes. The catalogue specifies a water penetration test in the region of the metallic screen according to IEC 60502-2 Annex D.




Reviews
There are no reviews yet.