SVBT 0.6/1 kV Copper Conductor Steel Tape Armoured PVC Power Cable – BDS 16291-85

The SVBT 0.6/1 kV copper conductor armoured power cable is designed for reliable electrical power transmission and distribution in industrial, commercial, and infrastructure applications. Manufactured according to BDS 16291-85, it features solid or stranded copper conductors, PVC insulation, a PVC inner sheath, steel tape armour, and a protective PVC outer sheath. Suitable for indoor and outdoor installations, including ducts, tunnels, canals, and shafts, this cable provides additional mechanical protection and dependable performance.

Application

SVBT cables are designed for transferring and distributing electrical power in switching installations and static installations. They are suitable for indoor installations, open-air installations, ducts, tunnels, canals, and shafts. Operating at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz, these cables provide reliable power distribution for various electrical infrastructure and industrial applications.

Cable Construction

The SVBT cable is manufactured according to BDS 16291-85 standards.

  • Conductor: Solid or stranded copper wires, Class 1 or Class 2, according to BDS 904-84 (IEC 60228).

  • Insulation: PVC compound.

  • Inner sheath: PVC compound.

  • Armour: Steel tapes (STA).

  • Outer sheath: PVC compound.

  • Outer sheath colour: Grey or black.

  • Conductor shape: Circular solid, circular stranded, or sector stranded conductor.

  • Compliance: RoHS compliant.

Technical Data

Parameter Specification
Applicable standard BDS 16291-85
Conductor standard BDS 904-84 (IEC 60228)
Conductor resistance at 20°C According to BDS 904-84
Maximum conductor temperature +70°C
Maximum short-circuit temperature +160°C, not more than 5 seconds
Rated voltage 0.6/1 kV
Test voltage AC 4 kV, 50 Hz / DC 12 kV
Minimum bending radius 15 × D (cable diameter)
Temperature of laying -5°C
Temperature range -30°C to +50°C
Flame test BDS IEC 332-1
Frequency 50 Hz
RoHS Compliant, as indicated in the product specification

Conductor Shape Identification

Code Conductor construction
re Circular, solid conductor
rm Circular, stranded conductor
sm Sector, stranded conductor

Color Coding

  • Single-core: Black, brown, blue, yellow/green, or other colours upon request.

  • Double-core: Blue and brown, or yellow/green and black.

  • 3-core: Brown, black, grey; yellow/green and blue; or other combinations according to the construction table.

  • 4-core: Brown, black, grey, blue, or yellow/green combinations.

  • 5-core: Blue, brown, black, grey, and yellow/green combinations.

  • Multiple-core: Black cores with number markings, or black cores with number markings and a yellow/green core in the outer cover.

Other constructions are available according to the product specification.

3. Construction Data Tables

The following tables reproduce the supplied SVBT 0.6/1 kV product specification. Copper weight and approximate cable weight are expressed in kg/km.

Construction Data – SVBT 0.6/1 kV (Table 1)

Nominal cross-section (N × mm²) Shape Outer diameter (mm) Cu weight (kg/km) Cable weight (kg/km)
1 × 10 rm 12.5 93 302
1 × 16 rm 13.5 148 381
1 × 25 rm 15.3 229 515
1 × 35 rm 16.4 325 624
1 × 50 rm 17.6 458 771
1 × 70 rm 19.9 648 1025
1 × 95 rm 21.6 885 1305
1 × 120 rm 23.3 1120 1575
1 × 150 rm 25.1 1378 1890
1 × 185 rm 27.7 1703 2307
1 × 240 rm 30.6 2208 2935
2 × 2.5 re 12.7 46 281
2 × 4 re 14.6 75 346
2 × 6 re 15.7 110 415
2 × 10 re 17.3 182 538
2 × 16 re 19.3 303 711
2 × 25 rm 23.7 470 1038
2 × 35 rm 25.9 652 1315
2 × 50 rm 29.4 928 1706
3 × 1.5 re 12.4 42 252
3 × 2.5 re 13.2 69 297
3 × 4 re 15.4 110 410
3 × 6 re 16.4 165 490
3 × 10 re 18.3 275 660
3 × 16 re 20.3 450 880
3 × 25 rm 25.0 700 1326
3 × 35 rm 27.5 980 1685
3 × 50 rm 31.3 1390 2210
3 × 70 sm 32.2 1950 2754
3 × 95 sm 36.7 2650 3670
3 × 120 sm 39.5 3350 4452
3 × 150 sm 43.1 4185 5388
3 × 185 sm 47.6 5160 6835
3 × 240 sm 53.4 6720 8501
3 × 2.5 + 1.5 re/re 13.7 82 295
3 × 4 + 2.5 re/re 16.0 132 450
3 × 6 + 4 re/re 17.1 202 545
3 × 10 + 6 re/re 19.1 330 736
3 × 16 + 10 re/re 21.2 540 996
3 × 25 + 16 rm/re 26.3 850 1514
3 × 35 + 16 rm/re 29.1 1130 1890
3 × 50 + 25 rm+rm 33.0 1630 2499
3 × 70 + 35 sm/rm 35.4 2280 3212
3 × 95 + 50 sm/rm 40.2 3120 4180
3 × 120 + 70 sm/rm 43.7 4010 5260
3 × 150 + 70 sm/rm 48.1 4850 6220
3 × 185 + 95 sm/rm 53.3 6070 7786

Construction Data – SVBT 0.6/1 kV (Table 2)

Nominal cross-section (N × mm²) Shape Outer diameter (mm) Cu weight (kg/km) Cable weight (kg/km)
3 × 240 + 120 sm/rm 59.6 7840 9910
4 × 1.5 re 13.2 55 286
4 × 2.5 re 14.1 92 350
4 × 4 re 16.5 146 480
4 × 6 re 17.6 218 580
4 × 10 re 19.8 363 800
4 × 16 re 22.0 582 1080
4 × 25 rm 27.4 925 1642
4 × 35 rm 30.4 1303 2175
4 × 50 rm 34.4 1857 2762
4 × 70 sm 36.6 2601 3478
4 × 95 sm 42.0 3540 4791
4 × 120 sm 45.4 4460 5800
4 × 150 sm 50.0 5575 7975
4 × 185 sm 55.2 6880 8117
4 × 240 sm 62.2 8928 10080
5 × 1.5 re 14.0 69 331
5 × 2.5 re 15.2 114 413
5 × 4 re 17.7 182 567
5 × 6 re 19.2 275 708
5 × 10 re 21.4 455 970
5 × 16 re 24.0 745 1324
5 × 25 rm 30.7 1165 2048
5 × 35 rm 33.4 1640 2758
5 × 50 rm 38.7 2330 3840
5 × 70 rm 43.7 3260 5128
7 × 1.5 re 15.2 96 421
8 × 1.5 re 16.2 110 465
10 × 1.5 re 18.3 140 571
12 × 1.5 re 18.8 165 610
14 × 1.5 re 19.5 195 675
16 × 1.5 re 20.5 220 740
19 × 1.5 re 21.3 260 814
24 × 1.5 re 24.5 330 1042
30 × 1.5 re 25.7 410 1180
37 × 1.5 re 27.7 506 1370
7 × 2.5 re 16.3 160 508
8 × 2.5 re 17.3 182 570
10 × 2.5 re 19.9 228 719
12 × 2.5 re 20.4 275 778
14 × 2.5 re 21.4 320 838
16 × 2.5 re 22.6 365 941
19 × 2.5 re 23.5 435 1050
24 × 2.5 re 27.0 546 1354
30 × 2.5 re 28.4 685 1551
37 × 2.5 re 30.8 845 1820

Note: The supplied specification permits simultaneous laying of the inner and outer sheath during extrusion.

Factory Overview


Packaging & Shipping


Frequently Asked Questions (FAQ)

Q:- What is the primary application of SVBT cable?

A:- SVBT cables are used for electrical power transmission and distribution in switching and static installations, including indoor, outdoor, open-air, duct, tunnel, canal, and shaft installations.

Q:- What standards does SVBT cable follow?

A:- The cable construction follows BDS 16291-85, while the copper conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor is used in SVBT cable?

A:- It uses solid or stranded copper conductors, available in circular solid, circular stranded, and sector stranded configurations.

Q:- What materials are used in SVBT cable construction?

A:- The cable consists of copper conductors, PVC insulation, a PVC inner sheath, steel tape armour, and a PVC outer sheath.

Q:- What is the purpose of steel tape armour?

A:- Steel tape armour provides additional mechanical protection against external damage, making the cable suitable for installations where mechanical protection is required.

Q:- What is the rated voltage of SVBT cable?

A:- The rated voltage is 0.6/1 kV.

Q:- What is the maximum operating temperature?

A:- The maximum conductor operating temperature is +70°C, while the maximum short-circuit temperature is +160°C for no more than 5 seconds.

Q:- What is the operating temperature range of SVBT cable?

A:- The specified temperature range is -30°C to +50°C, with a minimum laying temperature of -5°C.

Q:- What is the minimum bending radius?

A:- The minimum bending radius is 15 times the cable diameter (15 × D).

Q:- Is SVBT cable flame tested and RoHS compliant?

A:- Yes. According to the supplied product specification, it passes the flame test according to BDS IEC 332-1 and is RoHS compliant.