SAVTT 0.6/1 kV Aluminium Conductor PVC Insulated Power Cable – BDS 16291-85

The SAVTT 0.6/1 kV aluminium conductor power cable is designed for reliable electrical power transmission and distribution in industrial, commercial, and infrastructure applications. Manufactured according to BDS 16291-85, it features solid or stranded aluminium conductors, PVC insulation, a PVC inner sheath, and a protective PVC outer sheath. Suitable for indoor and outdoor installations, including rooms, canals, tunnels, shafts, and pits, this cable provides dependable performance with a maximum conductor operating temperature of +70°C.

Application

SAVTT cables are designed for transferring and distributing electrical power in switching installations. They are suitable for outdoor installations as well as indoor installations in rooms, canals, tunnels, shafts, and pits. These cables operate at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz, providing a reliable solution for low-voltage electrical distribution systems.

Cable Construction

The SAVTT cable is manufactured according to BDS 16291-85 standards.

  • Conductor: Solid or stranded aluminium wires, Class 1 or Class 2, according to BDS 904-84 (IEC 60228).

  • Insulation: PVC compound.

  • Inner sheath: PVC compound.

  • Outer sheath: PVC compound.

  • Outer sheath colour: Grey or black.

  • Conductor shape: Circular solid conductor, circular stranded conductor, or sector stranded conductor.

  • Compliance: RoHS compliant.

Technical Data

Parameter Specification
Applicable standard BDS 16291-85
Conductor standard BDS 904-84 (IEC 60228)
Conductor resistance at 20°C According to BDS 904-84
Maximum conductor temperature +70°C
Maximum short-circuit temperature +160°C, not more than 5 seconds
Rated voltage 0.6/1 kV
Test voltage AC 4 kV, 50 Hz / DC 12 kV
Minimum bending radius 10 × D (cable diameter)
Temperature of laying -5°C
Operating temperature range -30°C to +50°C
Flame test BDS IEC 332-1
Frequency 50 Hz
RoHS Compliant, as indicated in the product specification

Conductor Shape Identification

Code Conductor construction
re Circular, solid conductor
rm Circular, stranded conductor
sm Sector, stranded conductor

Color Coding

  • Single-core: Black, brown, blue, yellow/green, or other colours upon request.

  • Double-core: Blue and brown, or yellow/green and black.

  • 3-core: Brown, black, grey; yellow/green and blue; or other combinations shown in the construction table.

  • 4-core: Blue, brown, black, grey; or yellow/green, brown, black and grey.

  • 5-core: Blue, brown, black, grey, and yellow/green combinations as specified in the product table.

  • Multiple-core: Black cores with number markings, or black cores with number markings and a yellow/green core in the outer cover.

Other constructions are available according to the product specification.

3. Construction Data Tables

The following tables reproduce the supplied SAVTT 0.6/1 kV product specification. Aluminium weight and approximate cable weight are expressed in kg/km.

Construction Data – SAVTT 0.6/1 kV (Table 1)

Number of wires and nominal cross-section (N × mm²) Shape Outer diameter approx. (mm) Al weight (kg/km) Cable weight approx. (kg/km)
1 × 4.0 re 10.3 12 120
1 × 6.0 re 10.8 17 134
1 × 10 re 11.6 28 160
1 × 16 re 13.2 45 210
1 × 25 re 14.3 68 247
1 × 35 rm 15.4 95 295
1 × 50 rm 16.6 127 355
1 × 70 rm 18.4 190 465
1 × 95 rm 20.4 260 575
1 × 120 rm 22.0 325 663
1 × 150 rm 23.9 405 785
1 × 185 rm 26.2 510 951
1 × 240 rm 29.3 665 1193
1 × 300 rm 32.0 830 1450
1 × 400 rm 35.6 1060 1834
1 × 500 rm 39.9 1410 2265
2 × 2.5 re 11.5 14 155
2 × 4.0 re 13.4 23 212
2 × 6.0 re 14.3 34 248
2 × 10 re 15.9 56 307
2 × 16 re 17.7 90 389
2 × 25 re 21.4 137 545
3 × 2.5 re 12.0 21 165
3 × 4.0 re 14.0 36 233
3 × 6.0 re 15.0 51 277
3 × 10 re 16.7 85 345
3 × 16 re 18.7 135 444
3 × 25 re 22.0 210 626
3 × 35 rm 25.5 290 817
3 × 50 rm 29.1 385 1075
3 × 70 sm 30.0 585 1156
3 × 95 sm 34.5 810 1557
3 × 120 sm 37.3 1020 1823
3 × 150 sm 40.9 1255 2285
3 × 185 sm 45.4 1560 2730
3 × 240 sm 51.0 2035 3405
3 × 4.0 + 2.5 re/re 14.6 42 241

Construction Data – SAVTT 0.6/1 kV (Table 2)

Number of wires and nominal cross-section (N × mm²) Shape Outer diameter approx. (mm) Al weight (kg/km) Cable weight approx. (kg/km)
3 × 6.0 + 4.0 re/re 15.7 63 284
3 × 10 + 6.0 re/re 17.5 101 364
3 × 16 + 10 re/re 19.6 165 495
3 × 25 + 16 re/re 24.9 255 676
3 × 35 + 16 rm/re 27.1 340 900
3 × 50 + 25 rm/rm 30.8 480 1095
3 × 70 + 35 sm/rm 33.2 35? 1360
3 × 95 + 50 sm/rm 38.2 910 1840
3 × 120 + 70 sm/rm 41.5 1180 2210
3 × 150 + 70 sm/rm 44.9 1405 2735
3 × 185 + 95 sm/rm 50.9 1780 3425
3 × 240 + 120 sm/rm 55.7 2310 4276
4 × 2.5 re 12.9 28 152
4 × 4.0 re 15.1 46 216
4 × 6.0 re 16.2 68 260
4 × 10 re 18.2 112 340
4 × 16 re 22.0 180 460
4 × 25 re 25.5 270 670
4 × 35 rm 28.3 390 905
4 × 50 rm 32.6 520 1180
4 × 70 sm 34.4 760 1390
4 × 95 sm 39.6 1060 1860
4 × 120 sm 43.0 1340 2210
4 × 150 sm 47.6 1650 2710
4 × 185 sm 53.0 2100 3320
4 × 240 sm 60.0 2720 4110
5 × 2.5 re 13.8 35 180
5 × 4.0 re 16.4 58 270
5 × 6.0 re 17.6 85 320
5 × 10 re 19.8 140 430
5 × 16 re 24.3 225 580
5 × 25 re 28.9 345 855
5 × 35 rm 33.2 480 1210
5 × 50 rm 37.3 650 1470
5 × 70 sm 42.9 965 1955
5 × 95 sm 49.4 1345 2545

Important: The aluminium weight for 3 × 70 + 35 is difficult to read in the supplied image. It appears to be 670 kg/km, but should be confirmed against the original technical datasheet before publication.

Note: During extrusion, simultaneous laying of the inner and outer sheath is permitted.

Factory Overview


Packaging & Shipping


Frequently Asked Questions (FAQ)

Q:- What is the primary application of SAVTT cable?

A:- SAVTT cables are used for electrical power transmission and distribution in switching installations, outdoor installations, and indoor environments such as rooms, canals, tunnels, shafts, and pits.

Q:- What standards does SAVTT cable comply with?

A:- The cable construction follows BDS 16291-85, while its aluminium conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor is used in SAVTT cable?

A:- It uses solid or stranded aluminium conductors, available in circular solid, circular stranded, and sector stranded configurations.

Q:- What insulation and sheath materials are used?

A:- The cable features PVC insulation, a PVC inner sheath, and a PVC outer sheath for electrical insulation and mechanical protection.

Q:- What is the rated voltage of SAVTT cable?

A:- The rated voltage is 0.6/1 kV.

Q:- What is the maximum operating temperature?

A:- The maximum conductor operating temperature is +70°C. The maximum short-circuit temperature is +160°C for no more than 5 seconds.

Q:- What is the operating temperature range?

A:- The specified temperature range is -30°C to +50°C, with a minimum laying temperature of -5°C.

Q:- What is the test voltage of SAVTT cable?

A:- The specified test voltage is AC 4 kV at 50 Hz and DC 12 kV.

Q:- What is the minimum bending radius?

A:- The minimum bending radius is 10 times the cable diameter (10 × D).

Q:- Is SAVTT cable RoHS compliant and flame tested?

A:- Yes. The supplied product specification indicates RoHS compliance and a flame test according to BDS IEC 332-1.