SVTT 0.6/1 kV Power Cable – BDS 16291-85
The SVTT 0.6/1 kV cable delivers dependable power distribution for industrial and infrastructure applications. Constructed with solid or twisted copper conductors, PVC insulation, an inner sheath, and a grey or black PVC outer sheath, it offers excellent durability for outdoor and interior installations. Because it meets BDS 16291-85 standards and is RoHS compliant, it provides a safe and reliable solution for switching installations, canals, tunnels, and shafts.
Application
SVTT cables provide reliable power transfer and distribution for switching installations. Because they feature a robust PVC construction with an inner sheath, installers use them for outdoor installations as well as interior installations in rooms, canals, tunnels, shafts, and pits. Furthermore, they operate efficiently at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Consequently, they deliver consistent performance in demanding infrastructure environments.
Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features solid or twisted copper wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound. An inner sheath of PVC compound provides additional protection. Finally, a grey or black PVC compound outer sheath protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV 50 Hz and DC – 12 kV. Installers must respect a minimum bending radius of 10 times the cable diameter. The temperature of laying is -5 °C, and the temperature range is -30 °C to +50 °C. Furthermore, it passes the flame test according to BDS IEC 332-1.
Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, brown, blue, yellow/green, or other colors upon request. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data SVTT 0.6/1 kV
| Number of wires and nominal cross-section | Shape | Outer diameter approx. | Cu weight | Cable weight approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 1 x 1,5 | re | 9,5 | 14 | 108 |
| 1 x 2,5 | re | 9,9 | 23 | 124 |
| 1 x 4,0 | re | 10,3 | 37 | 146 |
| 1 x 6,0 | re | 10,8 | 55 | 170 |
| 1 x 10 | re | 11,6 | 93 | 221 |
| 1 x 16 | re | 13,1 | 148 | 285 |
| 1 x 25 | re | 14,3 | 229 | 412 |
| 1 x 35 | re | 15,4 | 325 | 458 |
| 1 x 50 | re | 17,4 | 456 | 600 |
| 1 x 70 | re | 19,1 | 648 | 800 |
| 1 x 95 | re | 21,6 | 885 | 1060 |
| 1 x 120 | re | 22,0 | 1120 | 1430 |
| 1 x 150 | re | 23,8 | 1378 | 1735 |
| 1 x 185 | re | 26,0 | 1703 | 2060 |
| 1 x 240 | re | 29,0 | 2208 | 2753 |
| 1 x 300 | re | 32,0 | 2785 | 3412 |
| 1 x 400 | re | 35,5 | 3780 | 4000 |
| 1 x 500 | re | 39,9 | 4600 | 5432 |
| 2 x 1,5 | re | 10,8 | 28 | 145 |
| 2 x 2,5 | re | 11,5 | 46 | 210 |
| 2 x 4,0 | re | 12,2 | 75 | 260 |
| 2 x 6,0 | re | 13,1 | 112 | 305 |
| 2 x 10 | re | 16,2 | 182 | 418 |
| 2 x 16 | re | 18,2 | 298 | 500 |
| 2 x 25 | re | 22,2 | 470 | 875 |
| 2 x 35 | re | 24,2 | 652 | 1235 |
| 2 x 50 | re | 27,0 | 928 | 1440 |
| 3 x 1,5 | re | 11,2 | 42 | 170 |
| 3 x 2,5 | re | 12,0 | 69 | 196 |
| 3 x 4,0 | re | 14,0 | 110 | 295 |
| 3 x 6,0 | re | 15,0 | 165 | 374 |
| 3 x 10 | re | 17,1 | 275 | 470 |
| 3 x 16 | re | 20,2 | 450 | 765 |
| 3 x 25 | re | 23,2 | 700 | 1125 |
| 3 x 35 | re | 26,2 | 900 | 1370 |
| 3 x 50 | re | 29,1 | 1390 | 1960 |
| 3 x 70 | re | 30,0 | 1890 | 2400 |
| 3 x 95 | sm | 35,0 | 2650 | 3080 |
| 3 x 120 | sm | 37,3 | 3350 | 4085 |
| 3 x 150 | sm | 40,5 | 4185 | 4900 |
| 3 x 185 | sm | 44,6 | 5160 | 6062 |
| 3 x 240 | sm | 51,0 | 6720 | 7950 |
| 3 x 4,0 + 2,5 | re/re | 14,6 | 132 | 330 |
| 3 x 6,0 + 4,0 | re/re | 15,7 | 202 | 390 |
| 3 x 10 + 6,0 | re/re | 18,7 | 330 | 550 |
| 3 x 16 + 10 | rm/re | 19,5 | 549 | 850 |
| 3 x 25 + 16 | rm/re | 24,9 | 850 | 1300 |
| 3 x 35 + 16 | rm/rm | 27,2 | 1189 | 1700 |
| 3 x 50 + 25 | sm/rm | 30,8 | 1630 | 2228 |
| 3 x 70 + 35 | sm/rm | 33,2 | 2280 | 2785 |
| 3 x 95 + 50 | sm/rm | 41,3 | 3150 | 4350 |
| 3 x 120 + 70 | sm/rm | 41,5 | 4010 | 4825 |
Construction data SVTT 0.6/1 kV
| Number of wires and nominal cross-section | Shape | Outer diameter approx. | Cu weight | Cable weight approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 3 x 150 + 70 | sm/rm | 44,9 | 4830 | 5750 |
| 3 x 185 + 95 | sm/rm | 50,9 | 6070 | 7250 |
| 3 x 240 + 120 | sm/rm | 56,7 | 7840 | 9350 |
| 4 x 1,5 | re | 12,0 | 55 | 198 |
| 4 x 2,5 | re | 13,4 | 92 | 246 |
| 4 x 4,0 | re | 14,7 | 146 | 360 |
| 4 x 6,0 | re | 16,0 | 218 | 451 |
| 4 x 10 | re | 18,6 | 363 | 655 |
| 4 x 16 | rm | 22,0 | 595 | 980 |
| 4 x 25 | rm | 25,8 | 970 | 1450 |
| 4 x 35 | rm | 28,4 | 1305 | 1850 |
| 4 x 50 | sm | 32,6 | 2301 | 2476 |
| 4 x 70 | sm | 34,9 | 2601 | 3060 |
| 4 x 95 | sm | 40,0 | 4460 | 5550 |
| 4 x 120 | sm | 43,0 | 5575 | 6750 |
| 4 x 150 | sm | 48,0 | 5855 | 8070 |
| 4 x 185 | sm | 52,9 | 6790 | 9275 |
| 4 x 240 | sm | 60,0 | 8928 | 10625 |
| 5 x 1,5 | re | 13,1 | 69 | 235 |
| 5 x 2,5 | re | 14,5 | 116 | 300 |
| 5 x 4,0 | re | 16,0 | 182 | 400 |
| 5 x 6,0 | re | 17,6 | 275 | 580 |
| 5 x 10 | re | 21,1 | 450 | 780 |
| 5 x 16 | rm | 23,2 | 745 | 1150 |
| 5 x 25 | rm | 28,9 | 1189 | 1830 |
| 5 x 35 | rm | 33,2 | 1690 | 2380 |
| 5 x 50 | sm | 35,0 | 2330 | 2630 |
| 5 x 70 | sm | 42,0 | 3230 | 4390 |
| 5 x 95 | sm | 49,0 | 4430 | 5940 |
| 8 x 1,5 | re | 14,8 | 110 | 318 |
| 8 x 2,5 | re | 16,5 | 180 | 560 |
| 10 x 1,5 | re | 16,9 | 140 | 380 |
| 10 x 2,5 | re | 19,5 | 225 | 560 |
| 12 x 1,5 | re | 18,7 | 220 | 480 |
| 12 x 2,5 | re | 20,9 | 270 | 600 |
| 14 x 1,5 | re | 19,8 | 195 | 500 |
| 14 x 2,5 | re | 22,7 | 330 | 710 |
| 16 x 1,5 | re | 20,0 | 230 | 450 |
| 16 x 2,5 | re | 22,8 | 330 | 700 |
| 19 x 1,5 | re | 22,6 | 270 | 630 |
| 19 x 2,5 | re | 26,8 | 411 | 765 |
| 21 x 1,5 | re | 24,2 | 280 | 730 |
| 24 x 1,5 | re | 26,4 | 440 | 840 |
| 30 x 2,5 | re | 28,5 | 695 | 1200 |
| 37 x 2,5 | re | 30,3 | 845 | 1520 |
| 7 x 1,5 | re | 15,0 | 96 | 310 |
| 7 x 2,5 | re | 17,0 | 163 | 385 |
| 7 x 4,0 | re | 19,0 | 255 | 584 |
| 7 x 6,0 | re | 18,0 | 384 | 735 |
Note: During the extrusion it is permitted simultaneous laying of the inner and outer sheath.
Factory Overview
Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SVTT cable?
A:- It is used for transferring and distributing electrical power in switching installations, as well as for outdoor and interior installation in rooms, canals, tunnels, shafts, and pits.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904-84 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses solid or twisted copper wires (class 1 or 2) with PVC insulation.
Q:- What is the purpose of the inner sheath?
A:- The inner sheath of PVC compound provides additional mechanical and environmental protection to the core assembly before the outer sheath is applied.
Q:- What is the temperature range for this cable?
A:- The temperature of laying is -5°C, and the operating temperature range is -30°C to +50°C.
Q:- What is the maximum conductor temperature and short-circuit limit?
A:- The maximum conductor temperature is +70°C. During a short circuit, it can withstand +160°C for no more than 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV 50 Hz and DC – 12 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).
Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to BDS IEC 332-1.
Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.


Reviews
There are no reviews yet.