SAVT 0.6/1 kV Aluminum Power Cable – BDS 16291-85

The SAVT 0.6/1 kV cable delivers dependable power distribution for industrial and infrastructure applications. Constructed with solid or twisted aluminum conductors, PVC insulation, and a grey PVC outer sheath, it offers excellent durability for outdoor and interior installations. Because it meets BDS 16291-85 standards and is RoHS compliant, it provides a safe and reliable solution for switching installations, canals, tunnels, and shafts.

Application
SAVT cables provide reliable power transfer and distribution for switching installations. Because they feature durable aluminum conductors and PVC insulation, installers use them for outdoor installations as well as interior installations in rooms, canals, tunnels, shafts, and pits. Furthermore, they operate efficiently at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Consequently, they deliver consistent performance in demanding infrastructure environments.

Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features solid or twisted aluminum wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound, and a grey PVC compound outer sheath protects the entire assembly. Notably, the cable may be produced with or without joint filling. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV 50 Hz and DC – 12 kV. Installers must respect a minimum bending radius of 10 times the cable diameter. The temperature of laying is -5 °C, and the temperature range is -30 °C to +50 °C. Furthermore, it passes the flame test according to BDS IEC 332-1.

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, brown, blue, yellow/green, or other colors upon request. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SAVT 0.6/1 kV

Number of wires and nominal cross-section Shape Outer diameter approx. Al weight Cable weight approx.
N x mm² mm kg/km kg/km
1 x 4,0 re 8,1 12 76
1 x 6,0 re 8,5 18 90
1 x 10 re 9,4 28 115
1 x 16 re 10,2 45 150
1 x 25 rm 11,9 70 200
1 x 35 rm 13,0 95 225
1 x 50 rm 14,2 127 265
1 x 70 rm 15,7 190 340
1 x 95 rm 18,4 260 460
1 x 120 rm 19,9 341 520
1 x 150 rm 21,9 405 605
1 x 185 rm 24,3 510 830
1 x 240 rm 27,2 665 1030
1 x 300 rm 30,0 830 1195
1 x 400 rm 33,6 1060 1595
1 x 500 rm 37,9 1410 2010
2 x 1,5 re 10,0 14 110
2 x 2,5 re 12,2 23 165
2 x 4,0 re 13,0 36 180
2 x 6,0 re 13,6 56 245
2 x 10 re 15,8 90 340
2 x 16 rm 21,0 157 370
2 x 25 rm 27,9 210 770
2 x 35 rm 28,8 290 830
3 x 1,5 re 12,8 36 185
3 x 2,5 re 14,9 56 255
3 x 4,0 re 15,1 70 270
3 x 6,0 re 16,8 135 380
3 x 10 re 18,2 210 610
3 x 16 rm 25,3 270 740
3 x 25 rm 28,8 385 950
3 x 35 rm 33,1 560 1090
3 x 50 rm 33,1 810 1450
3 x 70 rm 35,9 1020 1710
3 x 95 sm 41,9 1470 2420
3 x 120 sm 43,8 1560 2810
3 x 150 sm 49,4 2035 3320

Construction data SAVT 0.6/1 kV

Number of wires and nominal cross-section Shape Outer diameter approx. Al weight Cable weight approx.
N x mm² mm kg/km kg/km
3 x 4,0 + 2,5 re/re 13,4 42 205
3 x 6,0 + 4,0 re/re 15,2 61 260
3 x 10 + 6,0 re/re 19,2 101 320
3 x 16 + 10 rm/re 22,2 185 475
3 x 25 + 16 rm/re 26,3 270 825
3 x 35 + 16 rm/re 28,8 355 1005
3 x 50 + 25 sm/rm 30,8 480 1085
3 x 70 + 35 sm/rm 34,9 650 1455
3 x 95 + 50 sm/rm 37,0 910 1680
3 x 120 + 70 sm/rm 40,1 1180 2100
3 x 150 + 70 sm/rm 41,3 1450 2210
3 x 185 + 95 sm/rm 49,3 1780 2875
3 x 240 + 120 sm/rm 55,4 2310 3805
4 x 4,0 re 14,1 46 180
4 x 6,0 re 15,1 61 210
4 x 10 re 17,5 112 295
4 x 16 rm 19,8 180 460
4 x 25 rm 23,8 280 570
4 x 35 rm 28,0 320 1180
4 x 50 sm 33,0 520 1890
4 x 70 sm 34,0 740 2055
4 x 95 sm 41,4 1060 2210
4 x 120 sm 45,0 1340 2710
4 x 150 sm 51,0 1690 3410
4 x 240 sm 58,0 2720 4110
5 x 4,0 re 15,5 58 225
5 x 6,0 re 16,8 80 270
5 x 10 re 20,0 140 450
5 x 16 rm 23,2 225 580
5 x 25 rm 27,9 345 950
5 x 35 rm 31,0 485 1470
5 x 70 sm 42,0 985 1955

Note: Cable may be produced without joint filling.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SAVT cable?
A:- It is used for transferring and distributing electrical power in switching installations, as well as for outdoor and interior installation in rooms, canals, tunnels, shafts, and pits.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses solid or twisted aluminum wires (class 1 or 2) with PVC insulation and a grey PVC sheath.

Q:- What is the temperature range for this cable?
A:- The temperature of laying is -5°C, and the operating temperature range is -30°C to +50°C.

Q:- What is the maximum conductor temperature and short-circuit limit?
A:- The maximum conductor temperature is +70°C. During a short circuit, it can withstand +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV 50 Hz and DC – 12 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to BDS IEC 332-1.

Q:- What are the color coding options for the 3-core variant?
A:- The 3-core variant uses brown, black, and grey, or yellow/green, blue, and brown.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SAVT 0.6/1 kV Aluminum Power Cable – BDS 16291-85”