Bare Aluminum & ACSR Conductors – BS 215 Part 1 & 2

The bare aluminum and aluminum conductors steel reinforced (ACSR) deliver dependable overhead power transmission for exposed environments. Constructed with high-conductivity aluminum, and a galvanized steel core in the ACSR variants, they offer excellent tensile strength and minimal power loss. Because they comply with BS 215 Part 1 and Part 2 standards and are available in various cross-sections, they provide a reliable solution for overhead electric power transmission systems.

Application
Bare aluminum and steel-reinforced aluminum conductors (ACSR) provide reliable overhead power transmission. Because they offer excellent conductivity and high tensile strength, installers use them extensively in overhead electric power transmission networks. Furthermore, the steel-reinforced variants are ideal for long spans and areas requiring higher mechanical resilience. Consequently, they deliver consistent and efficient power distribution over long distances.

Cable construction
These conductors strictly adhere to BS 215 Part 1 and Part 2 standards. The standard bare aluminum conductors (Part 1) are constructed from high-conductivity aluminum wires stranded together. The ACSR variants (Part 2) combine an aluminum outer layer with a galvanized steel core for added mechanical strength. The stranding patterns and conductor diameters are engineered to optimize both electrical conductivity and breaking load for overhead applications.

Technical Data
The conductors deliver consistent performance under specific conditions. For the bare aluminum conductors (Part 1), breaking loads range from 1.227 kN (22 mm²) to 68.31 kN (400 mm²), with electrical resistance at 20°C ranging from 1.227 Ω/km to 0.0854 Ω/km. For the ACSR conductors (Part 2), breaking loads vary significantly based on the steel core, ranging from 9.61 kN to 131.90 kN. The ACSR electrical resistance ranges from 1.093 Ω/km down to 0.0874 Ω/km. These specifications ensure optimal conductivity and mechanical resilience.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, stranding, weight, and electrical resistance information.

Construction data Aluminum conductors BS 215 part 1

Nominal cross-section Stranding and wire diameter Conductor diameter Breaking load min Electrical resistance at 20°C, max Weight of conductor, approx.
mm² N x mm mm kN Ω/km kg/km
22 7×2,06 6,18 4,15 1,227 64
50 7×3,10 9,30 8,28 0,5419 145
80 7×3,60 10,80 9,90 0,3936 211
100 7×4,39 13,17 16,00 0,2702 290
150 19×3,25 16,25 25,70 0,1825 434
175 19×3,53 17,65 30,46 0,1549 507
250 19×4,22 21,10 40,48 0,1083 731
300 19×4,65 23,25 48,75 0,08916 888
400 37×3,78 26,46 63,10 0,05544 1145

Construction data Aluminum conductors, steel reinforced BS 215 part 2

Nominal cross-section Stranding and wire diameter Conductor diameter Breaking load min Electrical resistance at 20°C, max Weight of conductor, approx.
mm² N x mm mm kN Ω/km kg/km
25 6×2,36+1×2,36 7,08 9,61 1,093 106
40 6×2,82+1×2,82 8,46 13,48 0,7652 172
50 6×3,00+1×3,00 9,00 15,20 0,6756 172
60 6×3,35+1×3,35 10,05 18,17 0,5419 291
70 12×2,75+7×2,75 13,95 41,20 0,5399 538
100 6×4,72+7×1,57 14,15 32,70 0,2733 394
125 26×2,50+7×1,60 15,90 44,00 0,2733 520
150 18×3,35+1×3,35 16,75 35,70 0,1815 506
175 30×2,79+7×2,79 19,53 79,60 0,1576 842
200 18×3,99+1×3,99 19,95 47,90 0,1282 707
200 30×3,00+7×3,00 21,00 92,25 0,1363 974
200 18×3,99+1×3,86 19,90 46,55 0,1307 671
400 54×3,18+7×3,18 28,62 131,90 0,0874 1621

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of these bare aluminum and ACSR conductors?
A:- They are used for overhead electric power transmission systems, providing efficient and reliable power distribution over long distances.

Q:- What are the key benefits of the ACSR (steel-reinforced) conductors?
A:- The ACSR conductors combine an aluminum outer layer for high conductivity with a galvanized steel core for added mechanical strength, allowing for longer spans and higher tension.

Q:- What standards do these conductors follow?
A:- They strictly adhere to BS 215 Part 1 and Part 2 standards.

Q:- What materials are these conductors made of?
A:- Bare aluminum conductors are made of aluminum wires, while ACSR conductors are made of aluminum wires stranded around a galvanized steel core.

Q:- What is the smallest cross-section available for bare aluminum conductors?
A:- The smallest bare aluminum cross-section is 22 mm², with a stranding of 7×2.06 and a breaking load of 4.15 kN.

Q:- What is the largest cross-section available?
A:- The largest bare aluminum cross-section shown is 400 mm² (37×3.78), and the largest ACSR is 400 mm² (54×3.18+7×3.18).

Q:- How is the breaking load specified?
A:- The breaking load is specified in kilonewtons (kN) for each nominal cross-section, ensuring the conductor can withstand mechanical stress in overhead applications.

Q:- How does the electrical resistance change between bare aluminum and ACSR conductors?
A:- Bare aluminum resistance ranges from 1.227 Ω/km down to 0.0854 Ω/km. ACSR resistance ranges from 1.093 Ω/km down to 0.0874 Ω/km.

Q:- Is the stranding pattern consistent across all sizes?
A:- No, the number of wires and their diameter increase with the nominal cross-section to optimize breaking load and electrical conductivity.

Q:- What is the weight difference between bare aluminum and ACSR conductors?
A:- ACSR conductors are heavier due to the steel core. For example, a 400 mm² bare aluminum conductor weighs approx. 1145 kg/km, while a 400 mm² ACSR conductor weighs approx. 1621 kg/km.

Reviews

There are no reviews yet.

Be the first to review “Bare Aluminum & ACSR Conductors – BS 215 Part 1 & 2”

Your email address will not be published. Required fields are marked *